As TURNABLE ENTRY UNIT with M- LOCKS StraightBolt lock EM3520:
The diameter of the cable hole should be minimum 9 mm, maximum 12 mm. The hole must
be de-burred well to avoid damage to the cable. Cut the grooved shaft to the appropriate
length: Measure door thickness (from mounting surface of the entry unit to the mounting
surface of the lock) and add 41,5 mm (1.6”).
Prepare the mounting and cable holes according to picture
Hold the bearing plate in a way against the mounting surface that
“UP ROTATE” is readable on top. Affix the plate with the two
mounting adapter screws (M4) hand tied.
Insert first the spring and then the pin into the hole on the back cover
Insert the grooved shaft all the way into the entry housing