MacroAir Technologies 370 Airvolution D Installation Manual - page 20
© 2014 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 18
Rev. Date 111714
3.1 Touchpad Remote Mounting
3.1B Flush Mounting (Not Provided)
3.1.1B: Install the single gang
electrical box (not provided).
3.1.2B: Run the provided CAT5e cable
from the fan into the single gang
electrical box.
3.1.3B: Plug the remote cable into the
pre-wired CAT5e cable from the screen
using the provided RJ45 coupler.
3.1.4B: Secure the touch screen to the
enclosure using the 2 provided screws.
3.1.5B: Lock the provided bezel into
place via the plastic tabs.
3.1A Wall Mounting (Provided)
3.1.1A: Mount the base plate of the enclosure to the
wall using the 4 provided wall anchors and screws.
3.1.2A: Snap the front of the enclosure to the base
plate.
3.1.3A: Plug in the pre-wired CAT5e cable from the
screen into the RJ45 coupler inside the enclosure.
3.1.4A: Secure the touch screen to the enclosure
using the 4 provided screws.
3.1.5A: Lock the provided bezel into place via the
plastic tabs.
3.1.6A: Plug the provided CAT5e cable from the fan
into the RJ45 on the outside of the enclosure.
Note: The Touchpad Remote will automatically turn off after 30 seconds of inactivity. To turn the
screen back on, simply touch anywhere on the screen.
Note: 100 feet of CAT5e cable is provided standard. Up to 400 feet of cable can be ordered and 400
feet is the maximum distance allowed.
Refer to the next page for dimensions.
Components:
A - Base Plate
B - Front of Enclosure
C - Touch Screen
D - Bezel
E - Single Gang Electrical Box (not provided)
A
B
C
C
D
D
E