© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 1 rev. Date 111714.
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 1 rev. Date 111714 table of contents caution & safety ................................................................................................................................. 2 fan placement............
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 2 rev. Date 111714 caution & safety read the entire manual before operating the fan. Ensure that all safety practices and instructions are followed during the installation, operation and servicing of the fan....
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 3 rev. Date 111714 caution & safety key safety system components macroair fans are engineered with key safety features to prevent pieces of the fan from falling in the unlikely event of a catastrophic failure...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 4 rev. Date 111714 fan placement sprinkler systems and fan placement in any installation where fire sprinklers are in place, fan should not interfere with their correct operation. Fans should be located no le...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 5 rev. Date 111714 fan clearance & placement warning: fans are not meant to be operated in windy conditions. Maximum angle for mount (feet) slope (in) 0 2/12 4/12 6/12 8/12 10/12 roof angle 0 9.5 o 18.4 o 26....
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 6 rev. Date 111714 the model 370 has a standard airfoil to mounting point clearance of 2 feet [0.61 m] with the rapid mount industrial. Refer to the fan clearance & placement charts on page 5 for allowable mo...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 7 rev. Date 111714 fan components and tools a 2.442 8'-0" 0.609 2'-0" 0.442 1'-5" 0.721 2'-4" 8' airvolution d 300 series rapid mount commercial a-01 do not scale drawing ma08xs3706 sheet 1 of 1 8/5/2014 7/17...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 8 rev. Date 111714 step 1 - fan mounting choose the appropriate method for mounting the fan(s) based upon your specific application..
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 9 rev. Date 111714 rapid mount commercial a c components: a - locking set screws (2 locations on mount) b - extension attachment point c - break-outs for power wire, remote cable and safety cable b.
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 10 rev. Date 111714 1.1 unistrut span mounting components: a - 1/4-20 x 1” grade 5 bolts (4) b - 1/4”-20 unistrut spring nuts (p1006-1420) (4) c - liquid thread lock d - rapid mount commercial e - 1-5/8” unis...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 11 rev. Date 111714 components: a - 1/4-20 x 1” long grade 5 bolts (4) (not included) b - 1/4”-20 unistrut channel nuts (p3016-1420) (4) (not included) c - liquid thread lock (not included) d - rapid mount co...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 12 rev. Date 111714 1.2 i-beam installation (2 of 2) components: a - 1/2”-13 grade 5 bolts (4) (not included) b - 1/2” spring washer (4) (not included) c - unistrut beam clamps (p1386) (4) (not included) d - ...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 13 rev. Date 111714 components: a - 1/4 x 2” (minimum length) wood lags (4) (not provided) b - rapid mount commercial c - glulam d - extension attachment point this method is recommended for glulams or wood b...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 14 rev. Date 111714 components: a - 1/4 x 2” (minimum length) wood lags (4) (not provided) b - rapid mount commercial c - glulam d - extension attachment point 1.3.3: place the mount against the bottom of the...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 15 rev. Date 111714 step 2 - extension & motor unit installation attach the extension to the bottom of the mount and the motor to the bottom of the extension..
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 16 rev. Date 111714 components: a - 3/8-16 x 3” grade 5 (or higher) bolts (2) b - 3/8” flat washer (4) c - 3/8”-16 nylon locking nuts (2) d - rapid mount commercial e - extension f - motor unit 2.1.1: the ima...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 17 rev. Date 111714 step 3 - safety cable and electrical installation install the safety cable and insert the wires into the appropriate terminals on the controller..
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 18 rev. Date 111714 3.1 touchpad remote mounting 3.1b flush mounting (not provided) 3.1.1b: install the single gang electrical box (not provided). 3.1.2b: run the provided cat5e cable from the fan into the si...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 19 rev. Date 111714 3.1 touchpad remote drawings remote enclosure remote lcd display.
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 20 rev. Date 111714 a b a components: a - safety cable attachment point (minimum load rating 400 lbs) b - ac power source c - touchpad remote d - rapid mount commercial e - d-drive motor unit f - remote cable...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 21 rev. Date 111714 step 4 - airfoil installation remove the bottom cover, install the airfoils to the airfoil clamps and re-attach the bottom cover..
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 22 rev. Date 111714 components: a - 8-32 x 1-1/4’’ bolts b - bottom cover c - airfoil clamps d - remote cable e - power wires 3.1.1: remove the three allen bolts that secure the bottom cover and remove the bo...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 23 rev. Date 111714 components: a - 10-24 x 1-1/2’’ bolts b - airfoil c - airfoil clamps 4.1.2: insert an airfoil into one of the airfoil clamps and line up the three bolt holes. Insert an airfoil bolt into t...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 24 rev. Date 111714 components: a - 8-32 x 1-1/4’’ bolts b - bottom cover 4.1.4: re-install the bottom cover using the provided allen bolts and torque bolts snugly. Final results: 4.1 airfoil installation (3 ...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 25 rev. Date 111714 step 5 - touchpad remote navigation and operation choose one of the two methods to mount the touchpad remote and configure the fan diameter for initial operation..
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 26 rev. Date 111714 5.1 touchpad remote navigation buttons: a - forward / reverse: alternate between forward and reverse operation b - power button: turn the screen off c - speed up / speed down: increase or ...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 27 rev. Date 111714 5.2 touchpad remote operation screens: a - fan diameter selection screen b - home screen c - fault code screen d - operating hours screen instructions: 5.2.1: upon initial power-up, the to...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 28 rev. Date 111714 maintenance information guy wire check (if applicable): checking a macroair fan’s guy wires for tension and inspecting for frayed sections could mitigate a problem before it occurs. Fan ow...
© 2014 macroair technologies toll free: 866 668 3247 fax: 909 890 2313 www.Macroairfans.Com 29 rev. Date 111714 warranty and technical support to register the installed fans for the 50,000 hour warranty, go to macroairfans.Com/register. What does the 50,000 hour warranty cover? This warranty covers ...