Maga MA 15 Operation And Maintenance Manual - page 15
Functions of the CU:
This section contains information on the functions provided by the regulator unit, the methods of its adjustment, and how to view
the menu.
Initial Screen
(CH)
(Reg.)
The Boiler is not operating.
Under normal operation mode the regulator’s LCD display will show the
initial screen
where the following information can be
read:
•
Fire Off
•
Boiler Temperature
Boiler
•
Set Temperature (manually entered)
Reg.
The buttons
and
located on this screen (panel) allow quick changing of the
manually set temperature
.
By pressing the
push-button, a user will transfer to the first-level menu. The first two lines of the menu will appear on the
screen. In each of the menus you can navigate using the
and
arrow buttons. Pressing the
button will take
you to another submenu, or launch the currently displayed option.
By pressing the
push-button, a user will switch back to the initial menu.
Functions
Pressing the
button once will take you to the first-level menu.
Ignition:
By pressing the
button again, you will turn on the "firing boiler" function. The exhaust fan will smoothly
increase the speed of rotation, up to the maximum speed. Upon reaching the preset temperature, the "
fire up
" function will end
and switch to automatic mode - please see the Service Parameters.
Manual mode:
When operating under the manual control mode, the following components/functions can be switched on or off
using the
push button:
1) Fan Output (range from 0-100%)
2) Fan
3) Pump
4) Alarm
CH Pump Temp:
Temperature setting for main heating system circulating pump. Range is from 30°C to 60°C.
Alarm sound:
Option to silence the audio alarm.
Language:
The control unit allows changes of menu language unlimited times.
Default settings
: Once the "Default settings” item is set to YES, all settings will be reset to the default values set by the
manufacturer.
Boiler Protection and Errors:
15
62°C
82°C
Fire Off