Appendix A. Cabling Pinouts
Table A-3. DB9 Male Serial connector
Table A-4. T568B CAT5 pinout
Pin
Full Duplex
3 wire (SA)
Simplex
1
DCD
2
RX
RX
3
TX
TX
TX
4
DTR
5
Ground
Ground
Ground
6
DSR
7
RTS
8
CTS
9
RI
14
9
Appendix B. Setting Sync Signal
Output Termination
In some cases, it may be necessary to disable the 75-ohm termination of the video
outputs on the MultiView™ CAT5 Video System units. This can be done by opening
the case of each unit and installing jumpers on the circuit board. The settings disable/
enable the 75-ohm termination on individual units. For instance, changing a transmitter
termination affects the local monitor port only; it doesn’t affect the receivers.
Conversely, changing a receiver affects the output port of the receiver, not the
transmitter. The following diagrams show the jumper locations for each type of
assembly.
APPENDIX B: Sync Termination
75-ohm sync termination:
To enable: Both jumpers OUT
To disable: Both jumpers IN