Magnacom MAG-1001S User manual - page 9
Figure 2. RB-6V Battery Installation
2.2
lOW-bATTERY AlERT
The MAG-1001S is equipped with a unique low-battery alert. When the batteries
reach approximately 10 volts, you will hear a short beep every 2 minutes. At 9
volts, the beep tone starts to occur once a minute. When the battery voltage goes
below 8 volts, you will hear the tone every 30 seconds. When battery voltage
falls below 6 volts, the microcomputer switches the system power off, preventing
battery damage.
2.3 RECHARGEAblE bATTERY
The MAG-1001S comes with either two RB-6V batteries or a lithium battery.
When replacing the batteries per the instructions found in Section 2.1, ensure the
power harness in the battery compartment (Fig. 2, #8) is connected to J9 (Fig. 3,
#2) on the circuit board. This connection channels the battery charger’s current
to the batteries.
Note: The battery you receive may have upgraded specifications from what is stated
in this manual. Due to advancing battery technologies, we continually upgrade
our batteries and chargers. Contact OTS or your OTS dealer to find out the latest
available battery and charger.
2.4
CHARGING THE bATTERIES
Once replacement RB-6V rechargeable batteries are installed, charging is simple
6
Key
1. RB-6V rechargeable batteries
2. Wing nuts, retaining battery
bracket
3. Battery plate
4. Battery circuit board
5. Battery-retaining bracket
6. Battery-plate screws
7. MAG-1001S case
8. Battery wire harness
Battery makes contact
with circuit in any
position installed.
Note: RB-6V batteries shown