Magnum Energy ME Series Operator's Manual - page 35
Configuring the Inverter
T h e M E S e r i e s i n v e r t e r / c h a r g e r m u s t b e c o n f i g u r e d f o r L o w B a t t e r y C u t o f f (LBCO),
Shore Power Current, Charger Amps, Battery Size and Battery Type. These
operational parameters must be configured using the optional remote control.
R e f e r t o t h e M E S e r i e s R e m o t e C o n t r o l o p e r a t o r ’ s m a n u a l t o c o n f i g u r e t h e f o l l o w ing
parameters:
Shore (5, 10, 15, 20, 30, 50)
AGS OFF
Enable
M e t e r D C
A C
Setup Search
LBCO
Battery Bank
B a t t e r y T y p e
Charge Rate
C o n t r a s t
F a c t o r y R e s e t
Tech Temps F a u l t
Record
T h e M E S e r i e s i n v e r t e r / c h a r g e r a l s o a l l o w s y o u t o s e l e c t a n e q u a l i z e c h a r g e f o r
the batteries. Press and hold the Charger ON/OFF switch for 4 seconds. The Equali z e ( E Q ) f u n c t i o n w i l l
b e i n i t i a t e d ( a n d t h e c o r r e c t c o d e w i l l b e s e n t t o t h e r e m o t e . ) T h e E Q f u n c t i o n
a u t o m a t i c a l l y t e r m i n a t e s a f t e r 4 h o u r s o f o p e r a t i o n . Y o u c a n a l s o m a n u a l l y s t o p t h e
e q u a l i z e m o d e b y p r e s s i n g a n d h o l d i n g t h e C h a r g e r O N / O F F s w i t c h w h i l e t h e i n v e r t e r i s i n
E Q m o d e .