Magnum Energy ME Series Operator's Manual - page 56
3. Operation,
continued
L C D D I S P L A Y
INVERTING:
O F F -
U n i t i s “ O F F ” w i t h n o s h o r e o r g e n e r a t o r A C p o w e r a p p l i e d .
Search –
Unit is in search mode. AC loads are less than the search watts setting.
I n v e r t i n g –
U n i t i s i n v e r t i n g p o w e r f r o m t h e b a t t e r i e s i n t o 1 2 0 V A C a t its
output.
CHARGING:
B u l k C h a r g e –
The battery charger is delivering maximum current to the batteries. The
charger will remain in bulk charge until the bulk charge voltage is
achieved. See Chart 1.
NOTE: The maximum current can be reduced by adjusting the battery
charge rate and shore power settings using the setup options.
A b s o r p t i o n –
Absorption charge is the second stage of charging and indicates the bulk
voltage for battery type selected has been reached. The DC current will start
to taper off in order to maintain the bulk voltage setting. Absorption time is
determined by battery bank size selection. See Chart 2.
Figure 3
Menu Map
Ó 2003 - Magnum Energy, Inc.
9
Shore
5
10
15
20
30
50
AGS
Enable
O F F
TEST
Adj Search Watts
LBCO
Batt AHr
5 - 75 Watts
9 V D C
200
1 0 V D C
400
1 1 V D C
600
800
1000
METER
SETUP
TECH
GET TEMP ERATURES
Battery Temp Transformer
Temp FET Temp
SHOW VERSIONS
Remote V 0.xxx Inverter V
1.xxx
FACTORY RESET Push
and hold to reset to factory
default
Batt Type Charge Rate VAC Dropout Adjust Contrast Gel10 - 100%
60
VAC
0 - 100%
Liq Lead
8 0 V A C
AGM
1 0 0 V A C