Main Combi 25 Eco Elite User's Manual And Important Warranty Information

Summary of Combi 25 Eco Elite

  • Page 1

    © baxi heating uk ltd 2009 user’s guide and important warranty information combi eco range please keep these instructions in a safe place. If you move house, please hand them over to the next occupier..

  • Page 2

    2 © baxi heating uk ltd 2009 natural gas main combi 25 eco g.C.N o 47 467 01 main combi 30 eco g.C.N o 47 467 03 © baxi heating uk ltd 2009 all rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (...

  • Page 3

    1.0 quick reference guide 3 © baxi heating uk ltd 2009 reset bar 0 1 2 3 4 reset bar 0 1 2 3 4 on/off/reset selector switch display central heating temperature control domestic hot water temperature control & pre-heat selector system pressure gauge off position the boiler will not operate. Central h...

  • Page 4

    2.0 troubleshooting 4 © baxi heating uk ltd 2009 start make sure the gas supply is turned on and check if other gas appliances are operating (e.G. Fire, cooker). If no gas, consult your supplier. Is the on/off/reset select switch in the ( ) position and the display lit ? Is the ( ) or ( ) light on a...

  • Page 5

    2.0 troubleshooting 5 © baxi heating uk ltd 2009 is the timer on and calling for heat ? Ensure timer is set for central heating on (see any instructions supplied with timer). Is the room thermostat (if fitted) set high enough ? 15 10 5 20 25 15 10 5 20 25 turn room thermostat to maximum setting (typ...

  • Page 6

    3.0 repressurising system 6 © baxi heating uk ltd 2009 bar 0 1 2 3 4 bar 0 1 2 3 4 3.1 central heating system pressure 1. The normal operating water pressure is when the needle is in the green section of the gauge, between 1 and 2.5 bar (fig. 1). If the pressure exceeds 3 bar (needle in the red sect...

  • Page 7

    4.0 ‘intelligent pre-heat’ feature 7 © baxi heating uk ltd 2009 operation of pre-heat 1. The boiler incorporates an intelligent pre-heat feature that will ensure optimum domestic hot water performance. 2. This features ‘learns’ the domestic hot water demand, and pre-heats the boiler primary circuit ...

  • Page 8

    5.0 clearances 8 © baxi heating uk ltd 2009 fig. 7 fig. 8 200mm min 800mm 450mm 5mm min 5mm min 450mm min for servicing purposes in operation 5mm min 5.1 for your safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any...

  • Page 9

    6.0 care of the boiler 9 © baxi heating uk ltd 2009 6.1 cleaning the outer case the painted panels should be wiped with a damp cloth and then dried completely. Do not use abrasive cleaning agents. 6.2 protection & precaution 1. The boiler incorporates an integral frost protection feature that will o...

  • Page 10

    7.0 legislation 10 © baxi heating uk ltd 2009 7.1 installation, commissioning, service & repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In gb, this must...

  • Page 11

    8.0 emergency 11 © baxi heating uk ltd 2009 if you smell gas turn off the gas supply at the meter and call your gas supplier immediately. It is possible to isolate the boiler at the isolating valve (fig. 10). In gb, transco operate a 24 hour emergency service and the telephone number will be listed ...

  • Page 12

    9.0 warranty & service © baxi heating uk ltd 2009 m a i n a t r a d i n g d i v i s i o n o f b a x i h e a t i n g u k l t d ( 3 8 7 9 1 5 6 ) a d i v i s i o n o f b a x i g r o u p brooks house, coventry road, warwick. Cv34 4ll after sales service 0844 871 1570 technical enquiries 0844 871 1555 w...