Mainship 40 Trawler Single Operator's Manual - page 101
Mainship 40 Trawler Single & Twin • AC Electric Systems
8.9
Problem
Possible Cause
Solution
No AC power
Main breaker(s) in engine compart-
ment tripped or off
Breaker(s) at AC control center
tripped or off
Shore power cord not connected
Loose or disconnected wire
Turn breaker on or reset.
Turn breaker on or reset.
Check cord; plug in if necessary.
Tighten connections. See your dealer.
No power to AC devices
Breaker(s) at AC Control
Center tripped or off
Shore power cord not connected
Loose or disconnected wire
Turn breaker on or reset.
Check cord; plug in if necessary.
Tighten connections. See your dealer.
Inadequate power to AC devices
(generator running)
Electrical demand greater than gen-
erator output
Switch off devices and equipment not
needed.
Switch PARALLEL breaker off to
reduce demand.
Use shore power AC line if available
.
Continuous tripping of main breaker
Cause of problem not corrected
Determine cause and correct problem
before resetting breaker.
See your dealer if problem persists.
Generator will not start
Battery discharged or dead
Tried to start unit using remote starter
at generator
Recharge or replace battery.
If generator starts using remote
starter, have dealer check switches at
main panel and generator.
No power at AC outlets
Outlet breaker in AC control center
OFF
Ground fault interrupter tripped
Switch breaker to ON.
Reset button on outlet and test
TROUBLESHOOTING