Majestic 18NB Installation And Operating Instructions Manual

Summary of 18NB

  • Page 1

    This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to page 7. Warnings if the information in this manual is not followed exactly, a fire or explosion may result causing prop...

  • Page 2

    81d0108 18nb/24nb gas log set contents important safety information ..................................3 getting started ..........................................................5 product features and specifications ....................6 natural gas .....................................................

  • Page 3

    81d0108 3 18nb/24nb gas log set important safety information installer please leave these instructions with the appliance. Owner please retain these instructions for future reference. 1. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draper- ies....

  • Page 4

    4 81d0108 18nb/24nb gas log set important safety information continued from page 3 19. During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smell...

  • Page 5

    81d0108 5 18nb/24nb gas log set make sure you have received all parts: check your packing list to verify that all listed parts have been received. You should have the following: • unvented gas log burner assembly • two () plastic bags containing crushed volcanic rock • installation/operating instruc...

  • Page 6

    6 81d0108 18nb/24nb gas log set product features and specifications natural gas note: an external regulator is required to reduce supply pressure to a maximum of 10 1 / 2 " w.C. On natural gas systems operating at higher pressure. Millivolt regulator pressure setting: 3.5" w.C. Pilot regulator: 3.5"...

  • Page 7

    81d0108 7 18nb/24nb gas log set general installation information codes adhere to all local codes or, in their absence, the latest edition of the national fuel gas code ansi z3.1 or nfpa54 which can be obtained from… american national standards institute, inc. 1430 broadway new york, ny 10018 or nati...

  • Page 8

    8 81d0108 w h fp2250 clearances 18nb/24nb gas log set the following formula can be used to determine the maximum heater rating per the definition of unconfined space: btu / hr = (l1 + l) ft x (w) ft x (h) ft. X 1000 btu / hr 50 consider two connecting rooms with an open area between, with the follow...

  • Page 9

    81d0108 9 a c d b 18nb/24nb gas log set fireplace and hearth dimensions use manufacturer's installation and clearance requirements as defined in their manual. The nb series unvented room heater is approved for installation into the following unvented fireplaces: vf series fireboxes, magnum36/42, lo-...

  • Page 10

    10 81d0108 18nb/24nb gas log set placement in a fireplace with a restrictive barrier important information for the installation of this gas log set the following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom front opening of the fireplace. So...

  • Page 11: 16"

    81d0108 11 16" 42" 18nb/24nb gas log set clearances and height requirements sidewall and ceiling clearances: the sides of the fireplace opening must be at least 16" from any combustible wall. The ceiling must be at least 42" from the top of the fireplace opening. Figure 4 - sidewall and ceiling clea...

  • Page 12

    1 81d0108 measure this distance heater in fireplace or firebox heat resistant material 18nb/24nb gas log set figure 5 - measuring heat resistant material heat resistant material (minimum requirements) with no wooden mantel or other combustible projection: to install the gas logs into a fireplace wit...

  • Page 13

    81d0108 13 heater in fireplace or firebox 8" or more of heat resistant material hood 18nb/24nb gas log set clearances and height requirements figure 6 - measuring heat resistant material for mantel heat resistant material (minimum requirements) with wooden mantel or other combustible projection: to ...

  • Page 14

    14 81d0108 heater in fireplace or firebox heat resistant material hood 10" 12" 8" 6" 2 1 / 2 " 8" 14 1 / 2 " 18 5 / 8 " 22 1 / 2 " 26" heater in fireplace or firebox heat resistant material 10" 8" 6" 2 1 / 2 " 8" 14" 20 1 / 2 " 24 5 / 8 " 28" 18nb/24nb gas log set clearances and height requirements ...

  • Page 15

    81d0108 15 heater in fireplace or firebox heat resistant material 10" or less 12" min. 28" 2 1 / 2 " 8" 6" 7" 14 1 / 2 " 4" 18nb/24nb gas log set figure 10 - minimum mantel clearance with hood - 24nb (example of unsafe installation) figure 9 - minimum mantel clearance with no hood — 24nb example: th...

  • Page 16

    16 81d0108 heater in fireplace or firebox 1 3 / 8 " minimum combustible material 14" minimum heater in fireplace or firebox combustible material this distance may now be less than 1 3 / 8 " 18nb/24nb gas log set floor clearance the gas log heater must be installed at least 1 c\, " above any combusti...

  • Page 17

    81d0108 17 damper stop damper 18nb/24nb gas log set figure 13 - damper stop installation. Fireplace preparation before fully installing the unit: • turn off the gas supply to the fireplace or firebox. • seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace...

  • Page 18

    18 81d0108 18nb/24nb gas log set installing vented applications place and secure appliance assembly procedure: 1. Center the gas log unit on the fireplace or firebox. Make certain the front of the burner sits inside the front edge of the fireplace or firebox. . Anchor holes are located on the right ...

  • Page 19

    81d0108 19 fp2265 gas connection 18nb/24nb gas log set pipe coupling to heater valve gas supply inlet connecting the gas notice: a qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes. Important: hold heater valve firmly with a wrench to prevent moveme...

  • Page 20

    0 81d0108 18nb/24nb gas log set checking gas pressure the heater gas inlet connection is a 3/8" npt at the valve. On all control type units, the inlet connection is on the right side of unit. To connect from the opposite side, route the pipe around the back portion of the unit. When tightening up th...

  • Page 21

    81d0108 1 18nb/24nb gas log set electrical wiring (milli-volt) the milli-volt valve is a self-powered combination gas control that does not require 110 vac to operate. Connecting optional wall switch or thermostat 1. Use 18 awg, two-wire cable, 15 feet maximum length. . At one end of the cable, conn...

  • Page 22

    81d0108 remote receiver remote wire connectors remote wire connectors valve 18nb/24nb gas log set electrical wiring (milli-volt) connecting remote receiver 1. Set remote receiver. See instructions included in receiver kit. . Connect the two () 1/4" female connectors to the tp/th and th terminals on ...

  • Page 23

    81d0108 3 dime-size rock wool before you begin — this unit is supplied with seven (7) ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove an...

  • Page 24

    4 81d0108 log placement 5. Place left front log (#5) on left pin located on burner and left grate bar. Rest top right portion of log on right front log. Figure 24 6. Place top left log (#6) on left rear log (#4) and left front log (#5) using locating grooves on bottom of #6 and locating blocks on lo...

  • Page 25

    81d0108 5 ember, grate, and rock installation cast iron grate b . A. Cast iron grate i slot key hole slot 18nb/24nb gas log set figure 29 - installing cast iron grate place the decorative rock caution do not sprinkle volcanic rock on the logs, around the pilot, or on or near burners. This may cause ...

  • Page 26

    6 81d0108 fp2272 pilot correct flame fp2273 pilot bad flame 18nb/24nb gas log set flame appearance flames from the pilot and burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. Check the pilot flame the pilot fla...

  • Page 27

    81d0108 7 18nb/24nb gas log set in normal operation at full rate after 15 minutes, the following flame appearances should be observed: figure 32 - correct appearance of rear flames of highland oak burner will have a random pattern of yellow flames as shown in figure 35. There should be glowing ember...

  • Page 28

    8 81d0108 18nb/24nb gas log set figure 33 - location of piezo ignitor, control knobs and switch a. This appliance is equipped with a piezo ignition device which lights the pilot. If piezo is not working properly see match lighting instructions, page 30. B. Before operating smell all around the appli...

  • Page 29: To Turn Off Gas to Heater

    81d0108 9 18nb/24nb gas log set operating instructions 1. Stop! Read the safety information label. . Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refe...

  • Page 30

    30 81d0108 18nb/24nb gas log set operating instructions and cleaning and servicing cleaning and servicing annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. Periodic cleaning - refer to parts diagram for location of ite...

  • Page 31

    81d0108 31 18nb/24nb gas log set note: all troubleshooting items are listed in order of operation. Troubleshooting w arning w arning turn appliance off and allow to cool before servicing. Only a qualified service person should service and repair the heater. Observed problem possible cause remedy whe...

  • Page 32

    3 81d0108 18nb/24nb gas log set troubleshooting if the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. W arning observed problem possible cause reme...

  • Page 33

    81d0108 33 6 1 2 3 4 7 5 7 18nb/24nb gas log set replacement parts failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. W arning burner assembly.

  • Page 34

    34 81d0108 18nb/24nb gas log set replacement parts replacement parts are available through your retailer. Burner assembly item qty 18nb 24nb natural propane natural propane 1 piezo ignitor 1 14d0503 14d0503 14d0503 14d0503 piezo wire 1 00k063 00k063 00k063 00k063 3 burner 1 81d004 81d010 81d0515 81d...

  • Page 35

    81d0108 35 2 3 4 5 6 7 8 1 (beneath #7) 18nb/24nb gas log set replacement parts are available through your retailer. Replacement parts failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage ...

  • Page 36

    36 81d0108 18nb/24nb gas log set.

  • Page 37

    81d0108 37 18nb/24nb gas log set.

  • Page 38

    38 81d0108 18nb/24nb gas log set note regarding vented products this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Any residence with a direct vent product must have a co detector installed in the residence. Installation of the...

  • Page 39

    81d0108 39 18nb/24nb gas log set limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject of proof of purchase: firebox, combustion chamber, heat exchanger, grate, and stainless steel burners. Five year warranty the following c...

  • Page 40

    Mhsc 149 cleveland drive • paris, kentucky 40361 www.Mhsc.Com.