Majestic 18NB Installation And Operating Instructions Manual - page 4
4
81D0108
18NB/24NB Gas Log Set
IMPORTANT SAFETY INFORMATION
Continued from page 3
19. During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils,
films or bonding agents. These chemicals are not harmful
but may produce annoying smoke and smells as they are
burned off during the initial operation of the appliance;
possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last four hours to
properly cure logs and rock wool, with the burner at the
highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors
remaining after this initial break-in period will be slight
and will disappear with continued use.
0. Input ratings are shown in BTU per hour and are for
elevations up to ,000 feet. For elevations above ,000
feet, input ratings should be reduced 4 percent for each
1,000 feet above sea level. Refer to the National Fuel
Gas Code.
1. The appliance and its appliance main gas valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/ psig (3.5 kPa).
Never connect unit to private (non-
utility) gas wells. This gas is commonly
known as wellhead gas.
W
ARNING
MassaChussetts resiDents only:
Please see pages 40 & 41 for
additional information.
. The appliance must be isolated from the gas supply piping
system by closing its equipment shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/ psig (3.5 kPa).
3. Do not use this room heater if any part has been under
water. Immediately call a qualified service technician to
inspect the room heater and to replace any part of the
control system and any gas control which has been under
water.
4. This appliance must not be used with glass doors in the
closed position. This can lead to pilot outages and severe
sooting outside the fireplace.
5. Never burn solid fuels in a fireplace where a unvented
room heater is installed.
6. Always have a fireplace screen in place when the appli-
ance is in operation and, unless other provisions for
combustion air are provided, the screen must have an
opening(s) for induction of combustion air.
18NB, 24NB
Certified To
ANSI Z21.11.2a-2008
Unvented Heaters &
Z21.60b - 2004;
CSA 2.26b - 2004