    743000 bldv 7 cover dvbl7 series direct vent gas fireplace 74d3001 3/13 rev. 16 installation and operating instructions if the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – do not store or use ga...

  • Page 2

    74d3001 dvbl7 series gas fireplace contents important safety information ..................................... 3 code approval ............................................................. 4 product specifications................................................ 5 high elevations .......................

  • Page 3

    74d3001 3 dvbl7 series gas fireplace 4. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flam- mable objects are less than 4" from the front, top, or sides of the fireplace • in high traffic areas • in windy or drafty areas 5. This fireplace rea...

  • Page 4

    74d3001 4 dvbl7 series gas fireplace important safety information & code approval 1. Do not use this fireplace to cook food or burn paper or other objects. 13. Never place anything on top of fireplace. 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only ...

  • Page 5

    74d3001 5 dvbl7 series gas fireplace product features • this appliance has been certified for use with either natural or propane gas. See appropriate data plates. • this appliance is not for use with solid fuels. • the appliance is approved for bedroom or bedsitting room installations. • the applian...

  • Page 6

    74d3001 6 dvbl7 series gas fireplace pre-installation information r - rough opening width rough opening height rough opening depth a b c d e f g h i j k l m n o v q u t p 743000 bldv 7 dims o v s 1/2” or 5/8” (13 or 16 mm) gas line access 300dvbl 400dvbl 500dvbl a 34z\x" (876 mm) 37z\zn" (941 mm) 41...

  • Page 7

    74d3001 7 dvbl7 series gas fireplace before you start read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts...

  • Page 8

    74d3001 8 dvbl7 series gas fireplace pre-installation information fireplace location plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent con- figuration to be used, framing and finishing details, and whether any optional accessories (i.E...

  • Page 9

    74d3001 9 dvbl7 series gas fireplace clearances clearances to combustibles figure 4 - clearances from the mantel, ceiling, and side wall w arn in g follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot b...

  • Page 10

    74d3001 10 dvbl7 series gas fireplace the fireplace must be secured to the floor and/or to framing studs as shown in figure 5. Use two () wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/" or ...

  • Page 11

    74d3001 11 dvbl7 series gas fireplace venting installation information installation precautions consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fir...

  • Page 12

    74d3001 1 dvbl7 series gas fireplace venting installation information v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i fixed closed operable operable fixed closed b cfm145a dv termin location 5/01/01 rev. 12/05/01 sta inside corner detail...

  • Page 13

    74d3001 13 dvbl7 series gas fireplace fp2336 flex vent top venting installation information outside corner inside corner termination clearances termination clearances for buildings with combustible and noncombustible exteriors. G = combustible 6" (152 mm) noncombustible 2" (51 mm) f = combustible 6"...

  • Page 14

    74d3001 14 dvbl7 series gas fireplace venting installation information twist lock pipes when using twist lock pipe it is not necessary to use sealant on the joints. To join twist lock pipes together, simply align the beads of the male end with the grooves of the female end, twisting the pipe until t...

  • Page 15

    74d3001 15 dvbl7 series gas fireplace venting installation w arn in g horizontal sections of this vent system require a minimum of 3" clearances to combustibles at the top of the flue and 1" clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1" clearance all arou...

  • Page 16

    74d3001 16 dvbl7 series gas fireplace venting installation vertical sidewall application minimum clearance between vent pipes and combus- tible materials is 3" (76 mm) on top, and 1" (25 mm) on the bottom and sides unless otherwise noted. Refer to page 15 when vent termination exits through foundati...

  • Page 17

    74d3001 17 dvbl7 series gas fireplace venting installation vo584-100 vent opening 2/99 djt vent opening for combustible walls 9b\,” (44 mm) min. Fireplace hearth framing detail opening for noncombustible wall 7z\x” (190 mm) fireplace hearth fp93 figure 16 - locate vent opening on wall. 9b\,” (44 mm)...

  • Page 18

    74d3001 18 dvbl7 series gas fireplace venting installation step 7 guide the vent terminations 4” and 7” collard into their respective vent pipes. Double check that the vent pipes overlap the collars by ” (51 mm). Secure the termina- tion to the wall with screws provided and caulk around the wall pla...

  • Page 19

    74d3001 19 dvbl7 series gas fireplace venting installation . Remove soil to a depth of approximately 16” (406 mm) below base of snorkel. Install drain pipe. Install window well (not supplied). Refill hole with 1” (305 mm) of coarse gravel leaving a clearance of approximately 4” (10 mm) below snorkel...

  • Page 20

    74d3001 0 dvbl7 series gas fireplace venting installation 1 2 3 4 1 2 3 4 12” min. Figure 24 - maximum elbow usage fp1179 vertical through-the-roof installation note: for all top vent vertical through-the-roof installa- tions, install the supplied cross-bar flue restrictor onto the top edge of the f...

  • Page 21

    74d3001 1 dvbl7 series gas fireplace venting installation twl101a twist lock pipe 2/8/99 djt 3 #5 sheet metal screws per joint sealant storm collar twl101a figure 29 - roof flashing 2 ft. Min. 2 ft. Min. X 12 h* fp1971 min chimney clearance termination vent storm collar flashing lowest discharge ope...

  • Page 22

    74d3001 dvbl7 series gas fireplace fireplace installation check gas type use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. Instal...

  • Page 23

    74d3001 3 dvbl7 series gas fireplace fireplace installation note: the gas line connection may be made using 1/" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the nationa...

  • Page 24

    74d3001 4 dvbl7 series gas fireplace millivolt - checking gas pressure and electrical installation 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance. Contact your dealer ...

  • Page 25

    74d3001 5 dvbl7 series gas fireplace glass removal figure 33 - removing glass frame glass frame removal 1. Remove access panel by lifting up and out. . Release two clamps (500 model has three clamps) on bottom of fireplace. Figure 33 3. Tilt glass frame out and lift glass frame up until it clears th...

  • Page 26

    74d3001 6 dvbl7 series gas fireplace pilot hi lo on off fp2919 dv wiring diagram piezo ignitor thermocouple sparker thermopile pilot assembly switch on off millivolt valve on off optional 15’ wall switch remote wall mounted switch a remote wall switch and up to fifteen (15) feet of 18 ga. Wire may b...

  • Page 27

    74d3001 7 dvbl7 series gas fireplace 7. Remove screws securing engine base to firebox floor and lift engine up to remove. 8. Two () magnetic strips have been supplied to secure each blower to the firebox floor. Place on bottom of each blower before installing. Figure 37 9. The blowers are to be inse...

  • Page 28

    74d3001 8 dvbl7 series gas fireplace kt505 install blower start position installed position kt505 figure 39 - blower installation position note: some older units are not equipped with mounting brackets. Velcro and magnets are used to mount blowers to sidewall and floor. Optional fan/blower system th...

  • Page 29

    74d3001 9 dvbl7 series gas fireplace operating instructions - millivolt a. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. Before operating smell all around the appliance area for gas. Be sure to smell next to the f...

  • Page 30: Pilot

    74d3001 30 dvbl7 series gas fireplace operating instructions - millivolt pilot of f p il o t on fp1935 control knob pilot approved leak testing method you may check for gas leaks with the following methods only: • soap and water solution • an approved leak testing spray • electronic sniffer note: re...

  • Page 31: Pilot

    74d3001 31 dvbl7 series gas fireplace operating instructions - millivolt pilot of f pilot o n of f pilo t on pilot fp1937 control knob on on position pilot of f p il o t on fp1935 control knob pilot on/off/rs switch off on rs lighting burner main burner switch the “on/off/rs” switch for the main bur...

  • Page 32

    74d3001 3 dvbl7 series gas fireplace signature command - check gas pressure and electrical installation figure 43 - signature command valve fp1909a signature command valve alternate view 8/08 pressure inlet pilot adjust- ment screw pressure outlet 1. Check gas type. The gas supply must be the same a...

  • Page 33

    74d3001 33 dvbl7 series gas fireplace signature command - electrical installation junction box wiring 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with mini- mum 60° c wire in accordance with prevailing codes. . Remove the external junctio...

  • Page 34

    74d3001 34 dvbl7 series gas fireplace to junction box in fireplace optional ac module { white black optional light white black { optional blower white black { optional aux. Green plug in connector connector pin to control board input 300 watt max. Each optional a/c module replaces 6v adapter when us...

  • Page 35

    74d3001 35 dvbl7 series gas fireplace to junction box in fireplace white black white black black white green connector pin to contro l box { { optional light optional aux blower (300w max) fp2684 blotsdvsc fan wiring blower (300w max) figure 46 - blotsdvsc blower wiring diagram fp103 control box opt...

  • Page 36

    74d3001 36 dvbl7 series gas fireplace black black white green black black white receptacle junction box 120vac speed control fp2685 blotsdv blower wiring optional fan blower systems blotsdv automatic thermostat blower figure 47 - blotsdv blower wiring diagram fp685 before installing the blower, wire...

  • Page 37

    74d3001 37 dvbl7 series gas fireplace operating instructions - signature command a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. Before operating smell all around the appliance area for gas. Be sure to smell next to the floor ...

  • Page 38: Operating  Instructions

    74d3001 38 dvbl7 series gas fireplace operating instructions - signature command operating instructions 1. Stop! Read the safety information above. . This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) min...

  • Page 39

    74d3001 39 dvbl7 series gas fireplace features command center • easy access function operation and system configura- tion • operation confirmation/fault diagnostic indications (led/ buzzer) • on/off/hi/med/low operation • optional wall mounting control board • electronic ignition • pilot lockout saf...

  • Page 40

    74d3001 40 dvbl7 series gas fireplace signature command system operation instructions system configuration/setup all system configuration/setup is done on the command center. Note: when using on/off wall switch, the switch must be in the on position to perform all configuration set ups at the comman...

  • Page 41

    74d3001 41 dvbl7 series gas fireplace signature command system operation instructions fault led indication conversion cover missing one red (1 time) spark fail two red (1 time) no sensor signal three red (1 time) pilot lockout - trial one green, every sec. (until manual reset) pilot lockout - flame ...

  • Page 42

    74d3001 4 dvbl7 series gas fireplace log & rock wool installation figure 50 - rock wool placement rock wool placement 1. Place rock wool on burner to provide glowing embers. For best results, pull the rock wool apart into pieces the size of a dime or smaller. . Distribute one layer of rock wool to c...

  • Page 43

    74d3001 43 dvbl7 series gas fireplace 5. Place the middle cross log (#6) by matching the rectangular notch on the bottom of this log with the rectangular protrusion of the rear log toward the left. The narrow pointed end will line up between the second left tong and the middle tong on the grate. 6. ...

  • Page 44

    74d3001 44 dvbl7 series gas fireplace burner, pilot and control compart- ment keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstruction...

  • Page 45

    74d3001 45 dvbl7 series gas fireplace cleaning and maintenance vent system the fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering wi...

  • Page 46

    74d3001 46 dvbl7 series gas fireplace troubleshooting standing pilot ignition millivolt system symptom possible cause action 1. Spark ignitor will not light pilot after repeated triggering of piezo. . Pilot will not stay lit after carefully follow- ing lighting instruc- tions. 3. Pilot burning, valv...

  • Page 47

    74d3001 47 dvbl7 series gas fireplace troubleshooting standing pilot ignition millivolt system 4. Frequent pilot outage problem. 5. The pilot and main burner extinguish while in operation 6. Glass soots 7. Flame burn blue and lifts off burner (ghosting) a. Pilot flame may be too high or too low, cau...

  • Page 48

    74d3001 48 dvbl7 series gas fireplace troubleshooting operation install batteries and/or plug in the ac board flip the master switch (rocker switch) to the on position press the on button on the command center fault no beep in about 8 seconds no beep or no sound from the valve indicating pilot solen...

  • Page 49

    74d3001 49 dvbl7 series gas fireplace replacement parts 4 3 8 7 2 6 743000 bldv 7 parts 5 firebox components ref. Description qty. 300dvbl 400dvbl 500dvbl 1. Junction box assy (not shown) 1 6d18k 6d18k 6d18k . Sheet metal base 1 030194 74d0514 74d0515 3. Glass frame assy 1 0301034 74d0096k 74d011tk ...

  • Page 50

    74d3001 50 dvbl7 series gas fireplace replacement parts standing pilot — millivolt control 1 2c 2i 2t 2 4 5 6 3 8 9 7 10 11,12,13,14 743000 bldv millivolt parts.

  • Page 51

    74d3001 51 dvbl7 series gas fireplace replacement parts standing pilot — millivolt control ref. Description qty. 400dvblnv7 400dvblpv7 500dvblnv7 500dvblpv7 1. Gas valve assy 1 37d0117 37d0118 37d0117 37d0118 . Pilot assy 1 37d0018 37d0019 37d0018 37d0019 c. Replacement thermocouple 1 37d1067 37d106...

  • Page 52

    74d3001 5 dvbl7 series gas fireplace replacement parts signature command system 743000 bldv sc parts 1 2 3 4 20 5 6 7 8 9 13, 14, 15, 16, 17 12.

  • Page 53

    74d3001 53 dvbl7 series gas fireplace replacement parts signature command system accessories 13. Hand held remote control with hi/lo and timer rmsc 14. Hand held remote control with hi/lo and tstat rtsc 15. Touch screen remote w/opt. Light, aux & blower control tsfsc 16. Touch screen remote hi/lo an...

  • Page 54

    74d3001 54 dvbl7 series gas fireplace logs replacement parts 1 2 3 4 5 6 743001 dvbl logs ref. Description qty. 300dvbl 400dvbl 500dvbl 1. Rear log #1 1 030144 74d0059 74d0059 . Top right log # 1 030145 74d0060 74d0060 3. Front upper log #3 1 030146 74d0061 74d0061 4. Right front log #4 1 030147 74d...

  • Page 55

    74d3001 55 dvbl7 series gas fireplace venting components description model number vertical vent termination kits vertical vent termination w/ storm collar 7tdvskv (flashing not included) vertical vent termination w/ storm collar - 8 pack 7tdvskv/8 (flashing not included) vertical vent termination w/...

  • Page 56

    74d3001 56 dvbl7 series gas fireplace venting components description model number horizontal vent termination kits rear vent hot touch termination kit w/ 10" to 16" 7tbrhtk adjustable termination pipe, firestop, and hot touch termination w/ siding shield up and out side wall termination kit w/ 10" t...

  • Page 57

    74d3001 57 dvbl7 series gas fireplace venting components hot 1 2 3 4 5 6 9 7 8 11 10 0004 mldv vent parts current old duravent duravent or vermont or vermont qty./ castings group castings group selkirk metal-fab item box description part no. Part no. Part no. Part no. 1 1 thru-roof flexible pipe ter...

  • Page 58

    74d3001 58 dvbl7 series gas fireplace requirements for the commonwealth of massachusetts this product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of massachusetts. Note regarding vented products flex line installation must not exceed 36 inches and mus...

  • Page 59

    74d3001 59 dvbl7 series gas fireplace limited lifetime warranty policy lifetime warranty the following components are warranted for life to the original owner, subject to proof of purchase: firebox, combustion chamber, heat exchanger, grate and stainless steel burners. Five year warranty the followi...

  • Page 60

    Based on csa p.4.1-09 based on csa p.4.1-09 recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide selon csa p.4.1-09 efficiency ratings model energuide ratings fireplace efficiency (%) 300dvblnsc7 60. 400dvblnv7 63.8 400dvblnsc7 68.1 500dvblnv7 61.1 500dv...