Majestic 32LCUF-F Installation And Operating Instructions Manual - page 12
1
26D4751
GAS LINE INSTALLATION
Consultalllocalcodes.Allgaspipingmustbeinstalledtocomplywithlocalcodes,orintheabsenceoflocalcodes,with
thelatesteditionoftheNationalFuelGasCodeANSIZ223.1/NFPA54.
The
1
/
2
"gaslinemayentereitherfromtheleftsideorrightsideofthefirebox.Gasaccessholesareprovidedonbothsides
ofthefirebox.
Alistedmanualshutoffvalvemustbeinstalledupstreamoftheappliance.Aunionteeandplugged
1
/
8
"NPTpressuretapping
pointshouldbeinstalledupstreamofhteappliance.
IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning
on or shutting off the gas to the fireplace.
Asedimenttrapmaybeupstreamoftheheatertopreventmoistureandcontaminantsfrompassingthroughtraptotheheater
controlsandburners.Failuretodosocouldpreventtheheaterfromoperatingreliably.Consultapplicablecodes.
Anexternalregulatormustbeusedonallpropane/L.P.G.heaters,inadditiontotheregulatorfittedtotheheater,toreduce
thesupplytankpressureto13"w.c.(maximum).Anycoppertubingusedtosupplypropane/L.P.G.fromthetankmustbe
internallytinned.
Note: When connecting propane / L.P.G. vent-free room heaters, you must use pipe sealant resistant to
propane / L.P.G.
Important: Hold heater regulator with a wrench to prevent movement when connecting to inlet piping.
Check gas type: the gas supply must be the same as stated on the heater’s rating plate. If the gas supply
is different, DO NOT INSTALL THE HEATER. Contact your dealer for the correct model.
Aftercompletingconnection,testallgasjointsfromthegasmetertothegasheaterregulatorforleaks.Usingsoapandwater
solutionoragassniffer.DONOTUSEANOPENFLAME.
plumbing connections should only be performed by a qualified, licensed plumber. Main
gas supply must be off when plumbing gas line to fireplace or performing service.
W
ARNING
Connecting directly to an unregulated
propane / L.p.G. tank can cause an
explosion.
W
ARNING
Do not connect directly to natural gas 1/2 PSI or 2 PSI systems. Always make sure
natural gas pressure is regulated 10.5 w.c. (maximum before operating the unit).
W
ARNING