Majestic 32LCUF-F Installation And Operating Instructions Manual - page 18
Summary of 32LCUF-F
Page 1
For use with a listed gas-fired unvented decorative room heater not to exceed 40,000 btu/hr. Do not build a wood fire. Read and save these instructions warnings if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss ...
Page 2
26d4751 contents important safety information ................................. 3 product features ......................................................5 beforeyoustart.....................................................5 general installation information .............................6 fireboxexter...
Page 3
26d4751 9. Theinstallationmustconformwithlocalcodesor,in theabsenceoflocalcodes,withthenational fuel gas code, ansi z223.L/nfpa54. 10. Thisunitcomplieswithansiz21.91ventlessfirebox enclosuresforgas-firedunventeddecorativeroomheat- ers. 11. Donotinstallheaterinabathroomorbedroom. 12. Correctinstallat...
Page 4
26d4751 important safety information continued from page 3 16. Keeproomareaclearandfreefromcombustiblemateri- als,gasolineandotherflammablevaporsandliquids. 17. Unventedgasheatersareasupplementalzoneheater. Theyarenotintendedtobeaprimaryheatingappli- ance. 18. Unventedgasheatersemitmoistureintotheli...
Page 5
26d4751 5 the32lcufand36lcufc-rarevent-freefireboxes.Theyfeatureaselfcontainedheat-circulatingsystem.Thisinstallation manualwillenableyoutoobtainasafe,efficientanddependableinstallationofyourvent-freefireboxsystem. Donotalterormodifythefireboxoritscomponentsunderanycircumstances.Anymodificationoralt...
Page 6
6 26d4751 inplanningtheinstallationfortheapplianceitisnecessarytodeterminewheretheunitistobeinstalledandwhetheroptional accessoriesaredesired.Gassupplypipingshouldalsobeplanned.Thefollowingstepsrepresentthenormalsequenceof installation.Eachinstallationisunique,however,andmightrequireadifferentsequen...
Page 7
26d4751 7 minimum hearth dimensions general installation information and location of firebox figure 2 - minimum hearth dimensions location of firebox carefullyselectthebestlocationforinstallationofyour vent-freefirebox.Thefollowingfactorsshouldbetaken intoconsideration: • clearance to side wall, cei...
Page 8
8 26d4751 6" minimum 42" minimum 6" minimum ensurethatminimumclearancesshowninfigures4through7aremain- tained.Leftandrightclearancesaredeterminedwhenfacingthefrontof thefirebox. Followtheseinstructionscarefullytoensuresafeinstallation.Failureto followtheserequirementsmaycreateafirehazard. 1. Sidewal...
Page 9
26d4751 9 1" 10" 8" 6" 1 / " 1" 16" 19" 1" " combustiblematerial cancontacttopof fireplace. Non-combustible materialonlyif neededtocover radianttopfaceabove 5. Mantel clearances: thecanopysuppliedwiththeunitmustbeinstalled.Ifacombustiblemantelisinstalled,itmust meettheclearancerequirementsasshowninf...
Page 10
10 26d4751 h g d f e a c b a 1 / 2 " or 5 / 8 " c a g c g a firebox framing fireboxframingcanbebuiltbeforeoraftertheapplianceissetinplace.Constructfireboxframingfollowingfigures 9 through 12 andthechartbelowforyourspecificinstallationrequirements.See figure 1 on page 6 forfireboxdimensions. Theframi...
Page 11
26d4751 11 k j firebox framing 1. Bendoutthenailingflangeslocatedoneachsideofthefirebox. 2. Slidethefireboxintopreparedframingorpositionfireboxinitsfinalpositionandframelater. 3. Levelthefireboxbycheckingthetopedgeofthefirebox.Shimifnecessary. 4. Anchorfireboxtothesideframingmembersusing8dnailsoroth...
Page 12
1 26d4751 gas line installation consultalllocalcodes.Allgaspipingmustbeinstalledtocomplywithlocalcodes,orintheabsenceoflocalcodes,with thelatesteditionofthenationalfuelgascodeansiz223.1/nfpa54. The 1 / 2 "gaslinemayentereitherfromtheleftsideorrightsideofthefirebox.Gasaccessholesareprovidedonbothside...
Page 13
26d4751 1 canopy installation installing canopy acanopyisfurnishedwitheachfireboxandmust beinstalledforsafeoperation.See figure 15. 1.Removethethree(3)screwsfromthetopfrontframeassembly.Alsoremovethetwo(2)screwsonthesideframes. See figure 15. 2.Alignthecanopywiththeholesinthetopframe. 3.Replacethesc...
Page 14
1 26d4751 4 2 1 3 *not illustrated, see following page. Optional equipment and illustrated parts list optional wide canopy theoptionalwidecanopycanbeinstalled.Seeinstallationinstructionsprovidedwithkit. Item description qty 32lcuf-f 32lcuf-r 36lcufc-r 1 canopy 1 71d0071d0071d0500 screenpanel 0709070...
Page 15
26d4751 15 using optional ak-4 outside air kit 8'max. Combustion air 1. Locatecombustionairassemblyatanexteriorlocationwhichisnotlikelytobeaccidentallyblockedinanymanner. Locateassemblyamin.Of12"abovethesnowlinetopreventblockagebysnowaccumulation. 2. Nevermountthecombustionairinletassemblyinagarageo...
Page 16
16 26d4751 using optional ak-4 outside air kit theuseofoutsideairforcombustionisoptionalunlessrequiredbybuildingcodes.Itisonlynecessarytosupplyoutside combustionairtoonesideofthefireplace.Usethemodelak4combustionairkit. Model ak-4 combustion air assembly 1. Removethecoverplatefromthe4"outletopeningl...
Page 17
26d4751 17 model ak-4 combustion air assembly (continued) 7. Iftheductistheinsulatedtype,pushtheinsulationbackfromoneendof theductapproximately2".See figure 23. 8. Sliptheexposedendoftheductoverthestartingcollaronthefireplace. 9. Usingthesheetmetalscrewsprovided,securetheductendtothecollar attachedt...
Page 18
18 26d4751 notes.
Page 19
26d4751 19 limited lifetime warranty policy thefollowingcomponentsarewarrantedforlifetotheoriginalowner,subjectofproofofpurchase:firebox, combustionchamber,heatexchanger,grate,andstainlesssteelburners. Five year warranty thefollowingcomponentsarewarrantedfor5yearstotheoriginalowner,subjectofproofofp...
Page 20
August 2008 26d4751 • rev. 10 mhsc 19clevelanddrive•paris,kentucky061 www.Mhsc.Com.