Majestic 33BDVT Installation Instructions & Homeowner's Manual

Summary of 33BDVT

  • Page 1

    Installer: do not discard this manual - leave for homeowner 10002555 05/00 rev. 0 i nstallation i nstructions & h omeowner ' s m anual do not store or use gasoline or other flammable vapours and/or liquids in the vicinity of this or any other appliance. For your safety what to do if you smell gas: *...

  • Page 2

    33/36/39/43 bdvt -2- 10002555/0 vermont castings, majestic products. T able o f c ontents thank you & congratulations on your purchase of a vermont castings, majestic products fireplace. Please read the installation & operating instructions carefully before using the appliance. Important: read all t...

  • Page 3: & O

    10002555/0 -3- 33/36/39/43 bdvt vermont castings, majestic products. This gas replace should be installed by a qualied installer in accordance with local building codes and with current can /cga-b149 (. 1 or .2) installation codes for gas burning fireplaces and equipment. For u.S.A installations f...

  • Page 4

    33/36/39/43 bdvt -4- 10002555/0 vermont castings, majestic products. A ppliance d imensions appliance dimensions ref. 33bdvt 36bdvt 39bdvt 43bdvt a 838 mm (33") 914 mm (36") 991 mm (39") 1092 mm (43") b 733 mm (28.87") 870 mm (34.25") 870 mm (34.25") 940 mm (37") c 416 mm (16.37") 533 mm (21") 533 m...

  • Page 5

    10002555/0 -5- 33/36/39/43 bdvt vermont castings, majestic products. C learance to c ombustibles appliance top............................. 0 mm (0") bottom....................... 0 mm (0") side............................ 0 mm (0") back........................... 0 mm (0") venting concentric sectio...

  • Page 6: & M

    33/36/39/43 bdvt -6- 10002555/0 vermont castings, majestic products. Adjustable drywall strip a b c a = 1/2" (13 mm) drywall b = 5/8" (16 mm) drywall c = 3/4" (19 mm) drywall adjustable 13mm, 16 mm & 19 mm spacing f inal f inishing non-combustible materials such as brick or tile may be extended over...

  • Page 7: On/off S

    10002555/0 -7- 33/36/39/43 bdvt vermont castings, majestic products. G as l ine i nstallation when purging the gas lines, the front glass must be removed. The gas pipeline can be brought in through the rear of the replace as well as the bottom. Knockouts are provided on the bottom behind the valve ...

  • Page 8: Eb-1 E

    33/36/39/43 bdvt -8- 10002555/0 vermont castings, majestic products. Eb-1 e lectrical b ox the replace, when installed, must be electri- cally connected and grounded in accordance with local codes or, in the absence of local codes, with the current csa c22.1 canadian electric code. For u.S.A. Insta...

  • Page 9: Lp.

    10002555/0 -9- 33/36/39/43 bdvt vermont castings, majestic products. C onverting t he a ppliance f rom lp to n atural g as or n atural g as to lp. The conversion of this appliance from one gas to another must be carried out by an authorized service provider. 1. Disconnect power to the unit and shut ...

  • Page 10

    33/36/39/43 bdvt -10- 10002555/0 vermont castings, majestic products. E) mount the conversion label supplied with the conver- sion screw to the valve in a visible position. 10. Reassemble the replace in the reverse order, except for the front glass. Leave this off until the unit has been checked fo...

  • Page 11: — T

    10002555/0 -11- 33/36/39/43 bdvt vermont castings, majestic products. V v v v v v v v v x x x d e b b b c b m b a j k a f l g g termination cap air supply inlet gas meter restricted area (termination prohibited) h i fixed closed fixed closed openab le openable fixed closed g g n n a = clearance abov...

  • Page 12

    33/36/39/43 bdvt -12- 10002555/0 vermont castings, majestic products. Outside corner inside corner termination clearances termination clearances for buildings with combustible and noncombustible exteriors. A = combustible 6"(152mm) noncombustible 2"(50mm) b = combustible 6"(152mm) noncombustible 2"(...

  • Page 13: Dv C

    10002555/0 -13- 33/36/39/43 bdvt vermont castings, majestic products. H ow t o u se t he v ent g raph the vent chart should be read in conjunction with the follow- ing vent installation instructions to determin the relationship of the vertical and horizontal dimensions of the vent system 1. Determin...

  • Page 14

    33/36/39/43 bdvt -14- 10002555/0 vermont castings, majestic products. V ertical s idewall a pplications since it is very important that the venting system maintain its balance between the combustion air intake and the ue gas exhaust, certain limita- tions as to vent congurations apply and must be ...

  • Page 15

    10002555/0 -15- 33/36/39/43 bdvt vermont castings, majestic products. V ertical s idewall i nstallations step 1 locate vent opening on the wall. It may be necessary to rst position the replace and measure to obtain hole location. Depending on whether the wall is combustible or non-combus- tible, c...

  • Page 16

    33/36/39/43 bdvt -16- 10002555/0 vermont castings, majestic products. Step 6 use appropriate length of pipe sections - telescopic or xed - and install the horizontal vent sections. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (fig. 2...

  • Page 17

    10002555/0 -17- 33/36/39/43 bdvt vermont castings, majestic products. Do not back fill around snorkel. A clearance of at least 4” must be maintained between the snorkel and the soil gravel drain firestop foundation wall window well 7dvsks (snorkel) ground 24"/608mm minimum* 7" pipe screws minimum 4"...

  • Page 18: (33Bdvt

    33/36/39/43 bdvt -18- 10002555/0 vermont castings, majestic products. 1 2 3 4 1 + 2 + 3 + 4 = 270o max. 8' • 7dvcs must be used to support offsets. (fig. 38)this application will require that you rst determine the roof pitch and use the appropriate starter kit. (see venting components list) • the m...

  • Page 19

    10002555/0 -19- 33/36/39/43 bdvt vermont castings, majestic products. V ertical t hrough -t he -r oof i nstallation 1. Locate your replace. 2. Plumb to centre of the (4") ue collar from ceiling above and mark position. 3. Cut opening equal to 9-3/8" x 9-3/8" (240 mm x 240 mm). 4. Proceed to plumb ...

  • Page 20: / F

    33/36/39/43 bdvt -20- 10002555/0 vermont castings, majestic products. G eneral o perating i nstructions g lass i nformation only glass approved by vermont castings, majestic products should be used on this re- place. • the use of any non-approved replacement glass will void all product warranties. ...

  • Page 21: & L

    10002555/0 -21- 33/36/39/43 bdvt vermont castings, majestic products. I nstallation of l ogs & l ava r ock refer to the log identication chart to identify specic log numbers. 1. Remove the front glass / frame assembly. 2. Remove the logs from their packaging. The logs are fragile and should be han...

  • Page 22: & T

    33/36/39/43 bdvt -22- 10002555/0 vermont castings, majestic products. F lame & t emperature a djustment rn/rp & en/ep models for units equipped with ‘hi/lo’ valves the ame adjustment is accomplished by rotating the ‘hi/lo’ adjustment knob located near the centre of the gas control valve, fig. 47 & ...

  • Page 23: Lighting Instructions

    10002555/0 -23- 33/36/39/43 bdvt vermont castings, majestic products. Lighting instructions 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "off". Do not force. 5. Close control access panel. 10. Push the control knob all the way in and hold. Immediately li...

  • Page 24

    33/36/39/43 bdvt -24- 10002555/0 vermont castings, majestic products. L ighting and o perating i nstructions for fireplaces equipped with sit822 gas valve (en or ep) warning: if you do not follow these instructions exactly, a re or explosion may result causing property damage, personal injury and l...

  • Page 25

    10002555/0 -25- 33/36/39/43 bdvt vermont castings, majestic products. • gas supply on • supply line hooked up • shutoff valve open no no no no • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo — 1/8" gap to pilot hood needed. • all wiring connectio...

  • Page 26

    33/36/39/43 bdvt -26- 10002555/0 vermont castings, majestic products. Trouble shooting the gas control system sit nova 820 millivolt valve note: before trouble shooting the gas control system, be sure external gas shut off is in the "on" position. Warning: before doing any gas control service work, ...

  • Page 27

    10002555/0 -27- 33/36/39/43 bdvt vermont castings, majestic products. T rouble s hooting t he g as c ontrol s ystem sit 822 valve with a synetek electronic ignitor remove glass before servicing. Operating diagram on/off switch closed? Led on safe start check on? 0 sec. Purge ignition trial: 30 sec s...

  • Page 28

    33/36/39/43 bdvt -28- 10002555/0 vermont castings, majestic products. T rouble s hooting t he g as c ontrol s ystem sit 822 valve with a honeywell electronic ignitor remove glass before servicing. Start •turn gas supply off • turn on/off switch to "on" power to module (24v normal) spark across ignit...

  • Page 29

    10002555/0 -29- 33/36/39/43 bdvt vermont castings, majestic products. R eplacement p arts l ist items marked ‘*’ are not shown in the following parts pictorial page. Ref. Description 33bdvt 36bdvt 39bdvt 43bdvt 1 log set (complete) 10000470 1000023 10000024 10000025 1a log - front left ba2 bb6 bc5 b...

  • Page 30

    33/36/39/43 bdvt -30- 10002555/0 vermont castings, majestic products. 17b gas valve, honeywell rp 10001759 - - - 18a gas valve, sit822 en 57884 57884 57884 57884 18b gas valve, sit822 ep 57883 57883 57883 57883 * sensing electrode (with cable) en & ep 57885 57885 57885 57885 19 transformer, en & ep ...

  • Page 31

    10002555/0 -31- 33/36/39/43 bdvt vermont castings, majestic products. P arts p ictorial lo hi pi lo t a d j pil ot o n off hi lo 33bdvt 36bdvt 39bdvt 43bdvt 1a 1b 1c 1d 1e 1a 1b 1c 1d 1e 1a 1b 1c 1d 1e 1a 1b 1c 1d 1e 2a/b 22 21 17a/b 18a/b 16a/b 15 20 14 24 28 19 11 9 13 10 8 11 13 10 7 5a/b 3a/b 4a...

  • Page 32

    33/36/39/43 bdvt -32- 10002555/0 vermont castings, majestic products. O ptional a ccessories a vailable f an k its fk24 fan assembly this auxiliary fan system increases the efciency of the circu- lation of the heating air. The fk24 fan kit allows variable speed control of the circula- tion fan and ...

  • Page 33

    10002555/0 -33- 33/36/39/43 bdvt vermont castings, majestic products. 3. The second terminal of the speed control unit is attached to either terminal of the thermal sensor. 4. The second terminal of the thermal sensor is connected to either terminal of the fan motor. 5. The second fan motor terminal...

  • Page 34

    33/36/39/43 bdvt -34- 10002555/0 vermont castings, majestic products. D ecorative b ay w indows bay window kits are available for the 33bdvt, 36bdvt & 39bdvt model appliances. When tting the bay window kits the original front frame/glass assembly must remain in place. The bay window kit is tted ov...