Majestic 33BDVT Installation Instructions And Homeowner's Manual

Summary of 33BDVT

  • Page 1

    Installation instructions and homeowner’s manual installer: do not discard this manual - leave for homeowner c e rt i f i e d design cer tifie d 10003358 2/04 rev. 5 do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. What to do if you s...

  • Page 2: Table of Contents

    2 bdvt series direct vent gas fireplace 10003358 installation & operating instructions important curing/burning instructions ............................................................................... 3 locating your fireplace ........................................................................

  • Page 3

    3 bdvt series direct vent gas fireplace 10003358 a - flat on wall b - cross corner c - **island d - *room divider e - *flat on wall corner f - chase installation y - 6" minimum note (fig. 1): ** island (c) and room divider (d) installation is possible as long as the horizontal portion of the vent sy...

  • Page 4: Fireplace Dimensions

    4 bdvt series direct vent gas fireplace 10003358 fireplace dimensions f n- rough opening width rough opening height rough opening depth r r p o e g i d a m b j k l i gas line access gas line access low voltage electrical access electrical access c h q fig. 2 fireplace specifications and framing dime...

  • Page 5

    5 bdvt series direct vent gas fireplace 10003358 top of unit to ceiling ................................ 36” (914mm) appliance top ........................................................... 0” (0mm) bottom ..................................................... 0” (0mm) side ............................

  • Page 6

    6 bdvt series direct vent gas fireplace 10003358 33bdvt / 36bdvt / 39bdvt / 43bdvt certified to ansi z21.88-2002 / csa 2.33-2002 vented gas fireplace heaters noncombustible materials such as brick or tile may be extended over the edges of the face of the appliance. Do not cover any vent or grille pa...

  • Page 7

    7 bdvt series direct vent gas fireplace 10003358 installation: 1. Thread the wiring through holes on the end panels of appliance. Take care not to cut wire or insulation on metal edges. Route the wire to a conveniently located receptacle box. 2. Attach the wire to the on/off switch and install the s...

  • Page 8

    8 bdvt series direct vent gas fireplace 10003358 the eb-1 electrical junction box has been fitted standard on this model to allow for the easy connection of an optional fan kit. To connect the eb-1 box to the house electrical supply follow the steps below. 1. Unscrew retaining screw from eb-1 base p...

  • Page 9: General Venting

    9 bdvt series direct vent gas fireplace 10003358 your fireplace is approved to be vented either through the side wall, or vertically through the roof. • only venting components specifically approved and labelled for this fireplace may be used. • vent terminations shall not be recessed into a wall or...

  • Page 10

    10 bdvt series direct vent gas fireplace 10003358 v v v v v v v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i fixed closed fixed closed operable operable fixed closed v b inside corner detail v a g v n n v v g g a cfm145a general venting...

  • Page 11

    11 bdvt series direct vent gas fireplace 10003358 584-15 fig. 10 termination clearances. General information on assembling vent pipes canadian installations: the venting system must be installed in accordance with the current csa-b149 .1 installation code. Usa installations: the venting system must ...

  • Page 12

    12 bdvt series direct vent gas fireplace 10003358 20’ (6m) 7.5’ (2.3m) pipe straps every 3’ (914mm) firestop/zero clearance sleeve pipe straps every 3’ (914mm) fp1012 fig. 13 support straps for horizontal runs. • if a 90 ° elbow is used in the horizontal vent run (level height maintained) the maximu...

  • Page 13

    13 bdvt series direct vent gas fireplace 10003358 3’ (914mm) fp1237 fig. 14 maximum horizontal vent run. • the maximum number of 45 ° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run. • for each 45 ° elbow installed in the...

  • Page 14

    14 bdvt series direct vent gas fireplace 10003358 step 6 use appropriate length of pipe sections - telescopic or fixed - and install the horizontal vent sections. The sections which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (fig. 21) sealing vent pip...

  • Page 15

    15 bdvt series direct vent gas fireplace 10003358 measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. Refer to the sidewall vent graph for extended horizontal run if the vertical rise exceeds 24” (610mm). 1. Establish vent hole through the wa...

  • Page 16

    16 bdvt series direct vent gas fireplace 10003358 1 2 3 4 max. 8’ (2.4m) 1 + 2 + 3 + 4 = 270 ° fp1245 fig. 26 typical offset application. This gas fireplace has been approved for: • vertical installations up to 40’ (12m) in height. Up to a 10’ (3m) horizontal vent run can be installed within the ven...

  • Page 17

    17 bdvt series direct vent gas fireplace 10003358 when installing the 33bdvt with a vertical through- the-roof configured flue system the restrictor plate, (#10002495) supplied with the appliance must be fitted to the appliance at installation. Fitting the restrictor plate 1. Remove the window frame...

  • Page 18

    18 bdvt series direct vent gas fireplace 10003358 if there is a room above ceiling level, firestop spacer must be installed on both the bottom and the top side of the ceiling joists. If an attic is above ceiling level a 7dvais (attic insulation shield) must be installed. The enlarged ends of the ven...

  • Page 19

    19 bdvt series direct vent gas fireplace 10003358 twist lock venting components 7tdvrvt-through the wall rear vent termination starter kit-model7tdvsk-sidewall venting starter kit-model 7tdvskv-vertical venting for 7tdvskv-a order 1/12 to 6/12 roof pitch for 7tdvskv-b order 7/12 to 12/12 roof pitch ...

  • Page 20: Operating Instructions

    20 bdvt series direct vent gas fireplace 10003358 only glass approved by cfm specialty home products should be used on this fireplace. The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (fig. 34) the lower access door is hinged along the bottom ed...

  • Page 21

    21 bdvt series direct vent gas fireplace 10003358 unpack the logs from packaging and remove each log from its wrapping materials. The logs are fragile and should be handled with care. Keep the packaging material out of the reach of children and dispose of the material in a safe manner. The individua...

  • Page 22

    22 bdvt series direct vent gas fireplace 10003358 43bdvt refer to figure 39. 1. Remove the top louvre assembly. 2. Remove the window frame assembly. 3. Fit the rear left log (bd11) onto the rear log support. Ensure the back of the log is flat against the rear wall of the support. 4. Fit the front le...

  • Page 23

    23 bdvt series direct vent gas fireplace 10003358 rn/rp & en/ep models for units equipped with ‘hi/lo’ valves the flame adjustment is accomplished by rotating the ‘hi/lo’ adjustments knob located near the center of the gas control valve. (fig. 40 & 41) it is important to periodically perform a visua...

  • Page 24

    24 bdvt series direct vent gas fireplace 10003358 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "off". Do not force. 5. Close control access panel. 1. Stop! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For mn/mp/t...

  • Page 25

    25 bdvt series direct vent gas fireplace 10003358 lighting and operating instructions for fireplaces equipped with sit822 gas valve (en or ep) a. This fireplace is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. Before operating, smell...

  • Page 26

    26 bdvt series direct vent gas fireplace 10003358 troubleshooting honeywell millivolt valve remove window frame assembly before service work start check gas supply on ▼ ▼ ▼ ▼ ▼ pilot lights with piezo ignitor • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depres...

  • Page 27

    27 bdvt series direct vent gas fireplace 10003358 warning: before doing any gas control service work, remove glass front. Symptom possible causes corrective action 1. Spark ignitor will not light a. Defective or misaligned using a match, light pilot. If pilot lights, turn off electrode at pilot. Pil...

  • Page 28

    28 bdvt series direct vent gas fireplace 10003358 sit 822 valve with a honeywell electronic ignitor troubleshooting the gas control system start •turn gas supply off • turn on/off switch to call for heat "on" power to module (24v normal) spark across ignitor sensor gap yes yes yes • turn gas on pilo...

  • Page 29

    29 bdvt series direct vent gas fireplace 10003358 converting the appliance from lp to natural gas or natural gas to lp the conversion of this appliance from one gas to another must be carried out by an authorized service provider. 1. Disconnect power to unit and shut off gas supply. 2. Remove window...

  • Page 30: Maintenance

    30 bdvt series direct vent gas fireplace 10003358 maintenance burner and burner compartment it is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove an...

  • Page 31: 33/36/39/43Bdvt

    31 bdvt series direct vent gas fireplace 10003358 l ohi pilot adj pilo t on off hi lo 2a/b 18 17 13a/b 14a/b 12a/b 16 11 20 24 15 8 7 5 3a/b 4a/b 19 21 22 23 6 10 25 9 26 1f 1h 1b 33bdvt 1c 1a 1b 1f 1a 1e 1g 1c 1a 1d 1b 36bdvt 39bdvt 43bdvt cfm specialty home products reserves the right to make chan...

  • Page 32: Bdvt

    32 bdvt series direct vent gas fireplace 10003358 bdvt (continued) (items marked “*” are not shown.) ref. Description 33bdvt 36bdvt 39bdvt 43bdvt 1. Log set (complete) 10003685 10003353 100003354 10003696 1a. Log - front left --- bb11 bc11 bd12 1b. Log - front right ba9 bb12 --- bd14 1c. Log - rear ...

  • Page 33: Bdvt

    33 bdvt series direct vent gas fireplace 10003358 bdvt (continued) (items marked “*” are not shown.) ref. Description 33bdvt 36bdvt 39bdvt 43bdvt * fan speed control, (fk24 option) 51738 51738 51738 51738 * knob, fan speed control, (fk24 option) 51882 51882 51882 51882 18. Fan assembly, with bracket...

  • Page 34: Optional Accessories

    34 bdvt series direct vent gas fireplace 10003358 fk24 fan assembly this auxiliary fan system increases the efficiency of the circulation of the heating air. The fk24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit. Specifications 115 v...

  • Page 35

    35 bdvt series direct vent gas fireplace 10003358 the fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current csa c22.1 canadian electric code. For usa installations follow the local codes and the natio...

  • Page 36

    36 bdvt series direct vent gas fireplace 10003358 bay window kits are available for the 33bdvt/33bdvr, 36bdvt/36bdvr & 39bdvt/39bdvr model appliances. When fitting the bay window kits the original window frame assembly must remain in place. The bay window kit will fit over the existing window frame ...

  • Page 37

    37 bdvt series direct vent gas fireplace 10003358 basic warranty cfm specialty home products (hereinafter referred to collectively as the company) warrants that your new vermont castings or majestic gas fireplace/stove is free from manufacturing and material defects for a period of one year from the...

  • Page 38

    Efficiency ratings model energuide ratings steady state (%) d.O.E. Fireplace efficiency (%) fan-off fan-on (afue%) 33bdvtrn 54.2 76 78 57 33bdvtrp 54.2 77 79 57 33bdvten 54.2 76 78 57 33bdvtep 54.2 77 79 57 36bdvtrn 48.9 76 80 58 36bdvtrp 48.9 77 80 58 36bdvten 48.9 76 80 58 36bdvtep 48.9 77 80 58 3...