Decorative gas appliance installer: do not discard this manual leave for homeowner. Installation and homeowners operating instructions please read this manual before installing and using appliance important: read all instruc- tions and warnings carefully before starting installation. Fail- ure to fo...
2 majestic fireplaces ® nvc series b-vent 20000194 table of contents thank you and congratulations on your purchase of a vermont castings majestic products company fireplace. Please read the installation & operating instructions before using the appliance important: read all instructions and warning...
3 majestic fireplaces ® nvc series b-vent 20000194 installation & operating instructions this gas appliance should be installed by a qualified installer in accordance with local building codes and with current csa-b149.1 installation codes for gas burning appliances and equipment. If the unit is bei...
4 majestic fireplaces ® nvc series b-vent 20000194 a d n m n a b s g h j gas line access - 2" dia. Gas line access 2" dia. Finished wall thickness 6" flue rough opening height rough opening width rough opening depth c electrical cable knock-out - 1" dia. E l f k p q r electrical box knock-out - 2" d...
5 majestic fireplaces ® nvc series b-vent 20000194 clearance to combustibles appliances top ........................................... 0” (0mm) bottom ..................................... 0” (0mm) side ......................................... 0” (0mm) back ...........................................
6 majestic fireplaces ® nvc series b-vent 20000194 nvc36rn nvc36rp nvc36vn nvc36vp nvc36en nvc36ep nvc39rn nvc39rp nvc39vn nvc39vp nvc39en nvc39ep nvc43rn nvc43rp nvc43vn nvc43vp nvc43en nvc43ep natural propane natural propane natural propane natural propane natural propane natural propane natural p...
7 majestic fireplaces ® nvc series b-vent 20000194 gas line installation when purging gas line the fornt glass must be reomvoed. Purging gas lines must comply with the nfpa-54 or b-149. The gas pipeline can be brought in through the right or left side of the appliance, as well as the bottom. Knock- ...
8 majestic fireplaces ® nvc series b-vent 20000194 the fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current csa c22.1 canadian electrical code for usa installations follow the local codes and the nat...
9 majestic fireplaces ® nvc series b-vent 20000194 fig. 9 firestop/draftstop positions. Ceiling installation attic installation firestop position when area above ceiling is an attic. Firestop position when area above ceiling is not an attic. (firestop/draftstop appearances may vary. Only 1 firestop ...
10 majestic fireplaces ® nvc series b-vent 20000194 operating instructions only glass approved by the vermont castings majestic products company should be used on this fireplace. • the use of any non-approved replacement glass will void all product warranties. • care must be taken to avoid breakage ...
11 majestic fireplaces ® nvc series b-vent 20000194 5. Place the front right log on top of the burner, use bottom holes to locate the logs on top of the studs. 6. Place the top logs onto the locator notches. Ensure that the logs a re secure. (fig. 12) 7. Place ember material. See "ember material pla...
12 majestic fireplaces ® nvc series b-vent 20000194 test chimney draw a "chimney draw" test must be made before the installation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes. 3. Hold an ignited mat...
13 majestic fireplaces ® nvc series b-vent 20000194 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "off". Do not force. 5. Close control access panel. 1. Stop! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For mn/mp...
14 majestic fireplaces ® nvc series b-vent 20000194 vent safety switch this fireplace incorporates the use of a vent safety shut-off switch. The sensor and wiring are factory installed and should not be removed or altered during installation. In the event of total flue blockage the system will detec...
15 majestic fireplaces ® nvc series b-vent 20000194 troubleshooting fp649 turn gas supply off turn on/off switch to call for heat. No no no no no no no spark across ignitor sensor gap power to module (24v nominal) yes yes yes yes yes yes yes turn gas on pilot burner lights? Spark stops when pilot is...
16 majestic fireplaces ® nvc series b-vent 20000194 remove glass door before service work honeywell vs8421 start check gas supply on ▼ ▼ ▼ ▼ ▼ pilot lights with piezo ignitor • lockout has engaged. Wait 60 seconds and try again. • for spark at electrode while depressing piezo 1/8" gap to pilot hood ...
17 majestic fireplaces ® nvc series b-vent 20000194 troubleshooting fp396 gas supply on supply line hooked up shutoff valve open no no no no lockout has engaged. Wait 60 seconds and try again. Piezo nut tight for good ground. For spark at electrode while depressing piezo (red button) - 1/8" gap to p...
18 majestic fireplaces ® nvc series b-vent 20000194 cleaning the standing pilot control system the burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve most of these components may require only an occa- sional checkup and cleaning and ...
19 majestic fireplaces ® nvc series b-vent 20000194 194 31 28 29 26 6a/b 4a/b 5 36 35 34 1a 1b 1c 1d 1e nvc43 logs 1 27 37 2 3 1a 1b nvc36 1d 1e 1c 1e 1c 1a 1b 1d nvc39 1 18 25 17a/b 22 19 h i l o e a pil o t nova sit 822 valve 39a/b 9 11b 20/21 mv mvpv pv gnd (burner) 24v gnd 24v sense spark sit va...
20 majestic fireplaces ® nvc series b-vent 20000194 nvc36/39/43 (continued) ref. Description nvc36 nvc39 nvc43 4b. Burner housing w/tile-lp 10000028 10000694 10000030 5. Ceramic tile (single) 57803 57803 57803 6a. Orifice front burner-nat. See rating plate 6b. Orifice front burner-lp see rating plat...
21 majestic fireplaces ® nvc series b-vent 20000194 optional accessories fan kits fk12 fan assembly 1. Open louvre assembly bottom. 2. Install fk12 fan in back of unit between hearth supports. 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conv...
22 majestic fireplaces ® nvc series b-vent 20000194 remote controls optional remote control units are available to control different functions of the appliance. Model function(s) controlled mrc1 on/off mrc2 on/off and temperature mrc3 on/off and temperature control with a digital and a programmable ...
23 majestic fireplaces ® nvc series b-vent 20000194 fp1196 fig. 28 arched door front in place. Eb-1 electrical box standard on electronically controlled models, the eb-1 is also available for other fireplaces. Installation should be completed by a qualified service person. Decorative frame trims a s...
24 majestic fireplaces ® nvc series b-vent 20000194 basic warranty the vermont castings , majestic products company (hereinafter referred to collectively as the company) warrants that your new vermont castings or majestic gas fireplace/stove is free from manufacturing and material defects for a peri...