Panel Controls (Cont’d)
15. Morph CV Input:
Unity level, uni-polar CV input which sets Morph level. Range 0V to +5V.
16. CLK Input:
Synchronizes REC, Gene-Size, and Morph (see Page 23). Expects Clock or Gate of at least 2.5V in amplitude.
17. CV Output Activity Window:
Visual indication of the CV OUT signal.
18. CV Output:
Control signal representing the average energy of the signals at the Audio Outs (see Page 23). Range 0V to +8V
DC.
19. Play Gate Input:
Gate HIGH triggers or re-triggers playback from start of currently selected Splice. If held HIGH, Splice Loops.
If held LOW, playback stops at End of Splice. This input is normalled High, so with nothing patched to Play, the Splice loops.
Slide
offsets the Play Reset/ Start point.
20. REC Gate Input:
Clock or gate input for Record. Toggles Record ON/OFF. Expects Clock or Gate of at least 2.5V.
21. REC Button w/ Illumination:
Starts and stops recording. Lights to indicate that recording is happening. Press to Record into
same Splice or to initiate Time Lag Accumulation. The process starts upon the release of the REC Button. Hold REC Button and
Press Splice Button to Record into New Splice. While recording, press the REC Button to stop the Recording process. Also used for
Button Combinations (see Page 8).
22. Splice Button w/ Illumination:
Press to drop Splice marker on captured sound. Lights to indicate End of Splice/Gene. Also
used for Button Combinations (see Page 8).
23. Splice Gate Input:
Places Splice marker on captured sound based on incoming Gate HIGH. Expects Clock or Gate signal of at
least 2.5V.
24. Reel Activity Window:
Visual indication of currently selected Reel. Flashes to indicate signal at CLK IN and while in Reel Select
Mode. Strobes at High Gene-Size and Morph values to indicate excitement.
25. End of Gene/ Splice Gate Output:
Outputs Gate at the end of each Splice and/or Gene. 0 to 10Vpp (see Page 23).
26. Splice Activity Window:
Visual indication of currently selected Splice. Flashes to indicate Erase Splice, Erase Splice Audio,
Erase All Splices, and Erase All Audio.
27. microSD Card Slot:
For use of FAT32 formatted microSD cards only.
If inserted, microSD Card is mounted as soon as it is
recognized or when you press Shift Button. The Splice Button lights on to indicate the microSD card is mounted.
Do not remove
microSD Card while it is busy, as indicated by the Shift Button Flashing.
28. Shift Button w/ illumination:
Increments Splice selection. Lights on to indicate microSD Card is mounted. If SD Card is not
mounted on insertion, press Shift Button to mount inserted SD Card. Flashes to indicate “SD CARD BUSY!” Also used for Button
Combinations (see Page 8).
Do not remove microSD Card while it is busy, as indicated by the Shift Button Flashing.
29. Shift Gate Input:
Input to increment Splice selection. Expects clock or Gate of at least 2.5V in amplitude.
30. Organize Panel Control:
Manual unipolar control that selects next Splice to be played. The currently selected Splice or Gene
plays to the end before the next Splice is selected. In Reel Mode, used to select the Reel.
31. Organize CV Input:
Uni-polar control signal input for Organize. Range 0V to +5V. Unpatch when in Reel Mode to select Reel.
32. Slide Panel Control:
Manual control for traveling through the captured sound. Allows for scrubbing of the recorded material
and offsetting the Play Reset/Start point. This parameter is affected by the Gene-Size setting.
33. Slide CV Input:
Uni-polar control input for Slide. Range 0V to +8V.
34. Slide CV Input Attenuvertor:
Bipolar attenuator for Slide.