Gas Hook - Up
NEVER CONNECT AN UNREGULATED GAS
SUPPLY LINE TO THE APPLIANCE. USE THE
REGULATOR/HOSE ASSEMBLY SUPPLIED.
This is a LP gas configured grill. Do not attempt
to use a natural gas supply, the grill has not been
Regulator Connection
g
pp y
g
approved for natural gas use.
Total gas consumption (per hour) with all burners set on
“HIGH”:
Main burner 48,000 BTU/Hr.
Side burner 12,000 BTU/Hr.
Total
60,000 BTU/Hr.
3.
Make sure all burner valves are in their off position.
4.
Inspect valve connections, port, and regulator
assembly. Look for any damage or debris. Remove
any debris. Inspect hose for damage. Never attempt
to use damaged or obstructed equipment. See your
local LP gas dealer for repair.
LP GAS cylinder REQUIREMENT (9kg. Cylinder)
A dented or rusty LP gas cylinder may be hazardous and
should be checked by your LP gas supplier. Never use a
cylinder with a damaged valve. The LP gas cylinder
must be constructed and marked in accordance with
the specifications for LP gas cylinders for South Africa.
Storage of an outdoor cooking gas appliance indoor is
5.
When connecting regulator assembly to the valve,
hand tighten the wheel connection anti-clockwise to
a complete stop. Do not use a wrench to tighten.
Use of a wrench may damage the wheel and result
in a hazardous condition.
6.
Open the cylinder valve fully (counterclockwise).
Apply the soap solution with a clean brush to all gas
connections. See below. If growing bubbles appear
in the solution the connection is not properly sealed.
Storage of an outdoor cooking gas appliance indoor is
permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The
cylinder system must be arranged for vapor withdrawal.
The cylinder must include a collar to protect the cylinder
valve.
Remove the plastic valve cover from the LP gas cylinder.
Make sure the grill gas hoses do not contact the grease
pan or grill firebox when the LP gas cylinder is placed into
Check each fitting and tighten or repair if necessary.
the cart.
CONNECTION THE LP GAS CYLINGER
Your grill is equipped with gas supply orifices for use only
with LP gas. It is also equipped with a high capacity
hose/regulator assembly for connection to a standard
9kg. LP gas cylinder 52cm high, 30cm diameter. To
connect the LP gas supply cylinder please follow the
7.
If you have a gas connection leak you cannot repair,
turn gas OFF at supply cylinder, disconnect fuel line
from your grill and call (+27) 12 802 1515 or your
gas supplier for repair assistance. In case of severe
gas leaks or fie, contact your local fire department.
8.
Also apply soapy solution to the cylinder seams. See
below If growing bubbles appear shut cylinder OFF
connect the LP gas supply cylinder, please follow the
steps below:
1.
Make sure cylinder valve is in the complete off
position (turn clockwise to stop)
2.
Check cylinder valve to ensure it has proper
internal female threads.
below. If growing bubbles appear, shut cylinder OFF
and do not use or move it! Contact an LP gas
supplier or your fire department for assistance.
TO DISCONNECT THE LP GAS CYLINDER:
1.
Turn the burner valves off.
2
Turn the cylinder valve off fully (turn clockwise to stop)
2.
Turn the cylinder valve off fully (turn clockwise to stop).
3.
Detach the regulator assembly from the cylinder valve
by turning the wheel clockwise.