Megamaster MODO FIRE PIT - Y3 Assembly & Operating Instructions - Heater Stand And Location
7
HEATER STAND AND LOCATION
l
The heater is for outdoor use only. Always ensure that adequate fresh air ventilation is provided.
Always maintain proper clearance to combustible materials.
l
Heater must be placed on level firm ground.
l
Never operate heater in an explosive atmosphere like in areas where
gasoline or other flammable liquids or vapors are stored.
l
Keep a distance of at least 2 meters from Combustible Materials.
l
After every use, turn off the gas valve on the cylinder.
l
The heater should be protected from strong winds by activating the brake on the wheel.
GAS REQUIREMENTS
l
Use LP Gas only.
l
Only a 2,8kPa pressure regulator and hose assembly are to be used and must conform to local
standard SANS 1237.
l
The installation must conform to local codes, or in the absence of local codes, with the standard for
the storage and handling of liquid petroleum gases.
l
A dented, rusted or damaged LP Gas cylinder may be hazardous and should be checked by your
cylinder supplier. Never use a LP Gas cylinder with a damaged valve connection.
l
The LP Gas cylinder must be arranged to provide for vapor withdrawal from the operating cylinder.
l
Never connect an unregulated LP Gas cylinder to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater.
l
Make a soap solution of one part liquid detergent and one part water. The soap solution can be
applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
l
The heater must be checked with a full cylinder.
l
Make sure the safety control valve is in the OFF position.
l
Turn the gas supply ON.
l
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on
and recheck.
l
Never do leak test while smoking.
ADJUSTMENT TO BURNER OR REGULATOR
This appliance has been pre-set at the factory and NO adjustment may be made to the
burner or regulator.