10.7. MENU OVERVIEW
CHAPTER 10. ADDENDA
Looping means that, instead of staying at the SUSTAIN-level (L3) for as long as
the note keeps being pressed, the envelope goes immediatly into release and drops
back to zero, to restart from the beginning after arriving there. This way you can
use your ENV’s as a kind of user shapeable LFO’s. It’s also possible to get into the
PARAMETER-menu to alter the ENV Loop-setting over there.
On the screen, an ’x’ indicates that the envelope is not looping, while a number (1,
2 or 3) indicates that that envelope is in looping mode. It is not possible to set ENV4
into looping mode.
10.7
Menu overview
5