L
N
Wiring Diagram
The hob should be connected to a double pole
switch with a minimum gap of 3 mm. between
the switch contacts and of a type suitable for
the required load in compliance with the
current electric regulations. The switch should
be sited within 2m of the hob and be easily
accessible upon completion of the installation.
The switch must not break the yellow and
green earth cable at any point.
Ensure that the hob supply cord
does not come into contact with
surfaces with temperatures higher
than 50 deg. C.
Electrical connections
This hob is designed to be connected to a
230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated
on the hob rating plate. The rating plate is
located on the bottom of the hob. A copy is
attached on the back cover of this book.
The hob is supplied without supply cord. A 3
core flexible supply cord must be fitted, in
accordance with the specification given in the
relevant tables.
1) Remove the mains terminal cover
plate from the underside of the hob, to
expose the mains terminal block.
2) Loosen the two cable clamp screws and
lift the top section of the clamp enough to
allow the cable to be passed through.
3) Connect the red (live) wire to the terminal
which is marked with the letter "L".
4) Connect the black (neutral) wire to the
terminal which is marked with the letter "N".
5) After fitting a green or yellow/green sleeve
over the bare copper wire (earth wire),
connect the exposed end to the terminal
which is marked with the earth symbol
or with the letter "E"coloured green and
yellow.
NOTE: The earth wire should be about 2 cm.
longer than the live and neutral wires.
6) Secure the cable by means of the clamp
screws and refit the terminal block cover.
Supply Cable Specifications
Connection
Min. size
Cable / flex Fuse
via
Cable/flex type
Cooker
6 mm
2
PVC/PVC
30 A
Control
twin and
Circuit
earth
FO 0306
Grafiche MDM - Forlì