N-Tron 608MFX-ST Hardware Installation Manual - page 14
14
“Select/Set” Button
The "Select/Set" multi-functional button on the front panel of the 608MFX
performs the following actions:
•
Pressing the button briefly (similar to left mouse click) transitions the
display of the two display mode LED’s. The current display mode is
indicated by the status of the display mode LED’s per the legend
definition on the front of the 608MFX.
•
If the Display Mode is currently selecting port status (all Display Mode
LEDs off) and if the button is pressed for three seconds, the Display
Mode LEDs begin to flash. If you then continue to press the button for
a further two seconds, the 608MFX is reset. When the 608MFX is
reset, all the settings return to their defaults (as set in the factory). This
allows you to cancel settings made from the Web based management
tools, Telnet, or the command line configurator (serial port), or the fault
mask.
•
If the Display Mode is currently selecting the fault status and you press
the button for two seconds, the display LEDs start to flash. If you then
continue pressing the button for another two seconds, the current status
of the ports and the supply voltage are entered in the fault mask. Any
change in their status after the fault mask update will create a fault.
Note: Do not press the “Select/Set” button while the unit is powering up. In the
event that the "Select/Set" button was pressed while the 608MFX is starting up
(approximately a 20-second window), all display mode LEDs will flash
simultaneously. This mode is exited by pressing the button again after the unit
has completely powered up (a 20-second delay).