Nagra NAGRA-V Operating Instructions And Reference Manual - 8 9
Chapter I
5
Jan 2003
FRONT PANEL
Light / Battery Switch (1)
This three position switch has several functions which are depending on how it is used:
Cloud position means modulometer and display backlights are ON
Sun positon means modulometer and display backlights are OFF
BATT. Position can have several operations:
The meter will indicate the state of the batteries in the battery box
.
The green area on the
meter gives the corresponding power indication assuming the correct type of batteries is
selected in the menu.
Temporary backlight of the modulometer and display.
Selection of MONO in the headphones while held down.
If pressed during power-up of the machine, the type of batteries or external power
selected will be automatically set to lowest acceptable input voltage. (See Battery menu)
The LCD display will scroll through the presently selected menu settings, the default
settings are:
MASTER
Reference frequency is the internal master clock
48 KHZ
Sampling rate selected
BWF 24
Record format and bit rate on the HDD
ANALOG
Analogue input selection
POT OUT
Aux IN / Line pot selection set for Line Output
LEV AUTO
Modulometer selection in automatic (not present if modulo is set
before line out).
LINE OUT
Monitoring via Line Output
SPK AUTO
Loudspeaker mode selection in automatic
If the BATT position is pressed twice then the LCD display will scroll through the Time Code settings.
The default TC settings are:
25 FPS
Selected Time Code frame rate
INT. GEN.
Record source
TC. EXT.
Reference for chase mode
FIX. CLK
Internal clock for sync mode
.