    1 operating guide for your gem-rp1cae2 keypad © napco 2006 arm ed c o mp ut erize d secur i ty sy st em sta tus g e m in i a 1 2 3 b 4 5 6 c 7 8 9 0 e f g j system ready 09/01/07 12:09 am next / yes prior / no area oi234i 8/06.

  • Page 2

    2 the gem-rp1cae2 is a “smart” user-friendly, interactive menu-driven keypad designed for your napco control panel. Its alphanumeric screen will not only display the status of your system, but will also give you step-by-step instructions to guide you through all operations. This booklet contains imp...

  • Page 3

    3 t ab l e o f c o n t e n t s table of contents section page keypad controls & indicators ............................................ 4 setting the alarm (arming) when leaving ....................... 6 protecting yourself while on the premises ................ 8 turning off the alarm (disarming) w...

  • Page 4

    4 k e y p ad c o n t r o l s & i n d i c at o r s arm ed c omp uter i ze d s ec ur i ty sys t em sta tus g e m in i a 1 2 3 b 4 5 6 c 7 8 9 0 e f g j system armed 09/01/07 12:07 am 1 2 3 4 5 6 7 12 8 9 10 11 next / yes prior / no area.

  • Page 5

    5 k e y p ad c o n t r o l s & i n d i c at o r s window. Displays system status messages, zone descriptions, etc. Status light. Lights (green) to indicate that the system is ready for arming. If a zone is not secured the light will be off and the zone will display in the window. If a zone has been ...

  • Page 6

    6 s e t t i n g t h e al ar m ( ar m i n g ) w h e n l e av i n g z o n e s f a u l t e d 0 2 b a c k d o o r bypassed b y p a s s e d bypassed 0 2 b a c k d o o r arming the system 1 check the keypad. The green status light must be on in order to arm. If the green light is off, “zones faulted” will...

  • Page 7

    7 s e t t i n g t h e al ar m ( ar m i n g ) w h e n l e av i n g system trouble if you attempt to arm with a “system trouble” display alternating with an indicated trouble code (e.G. “e02-00” (low battery); see system trouble error codes), a 3-second tone will sound at the keypad. The window will d...

  • Page 8

    8 bypassing interior zones i nterior zones, when bypassed, allow free movement within the home while the protection of armed perimeter zones is maintained. To bypass interior zones, press e and enter your user code followed by d . Your system may have provisions for two groups of interior zones. (op...

  • Page 9

    9 p r o t e c t i n g y o u r s e l f w h i l e o n t h e p r e m i s e s easy exit (optional - easy exit programmed? Yes no) your system may have been programmed for easy exit, which allows a user to exit the premises while the system is armed. By activating easy exit while the system is armed, the...

  • Page 10

    10 disarming the system 1 enter your premises through the entry/exit door. The keypad will sound a steady or pulsing tone to remind you to disarm the system before your entry delay time expires. 2 enter your user code and press d. The red armed light will go out, indicating that the system has been ...

  • Page 11

    11 f i r e p r o t e c t i o n (applicable only where local ordinance permits use of this alarm control panel for fire protection.) fire-zone alarm if a fire is detected, “fire alarm” will be displayed and the keypad sounder will pulse. In addition, the "fire" icon will flash. 1. If a fire is in pro...

  • Page 12

    12 f i r e p r o t e c t i o n preparing a fire escape plan even with the most advanced fire alarm system, adequate protection requires an escape plan. To prepare your plan, draw floor plans of your building. (space is provided on the next page). Show two exits - a front or back door and a window fr...

  • Page 13

    13 f i r e p r o t e c t i o n floorplan draw a plan of your premises in the space provided below. Floorplan.

  • Page 14

    14 f i r e p r o t e c t i o n although a fire alarm system may be of a reliable and state-of- the-art design, neither it nor its peripheral detection devices can offer guaranteed protection against fire. Any such equipment may fail to warn for a variety of reasons: control panels, communicators, di...

  • Page 15

    15 k e y p ad f u n c t i o n s the keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting “yes/no” format. 1 to enter the function menu, press a . • in all ul-listed or high-security installations, a valid user code must first be entered foll...

  • Page 16

    16 activate bell test? Activates the alarm (while disarmed) for about 2 seconds and performs a battery test. If the alarm does not sound, call for service. • if the battery is low, a “low battery e02-00 service” will appear in the display indicating a low battery condition. Allow 24 hours for the ba...

  • Page 17

    17 k e y p ad f u n c t i o n s reset system trouble? System troubles display and sound at the keypad. Correcting the trouble will clear most indications, however the following error codes will require manual reset: e13; e19; e20 and e22. (see system trouble error codes for a description of error co...

  • Page 18

    18 k e y p ad f u n c t i o n s activate telephone test? (telephone test programmed? Yes no). Sends a communicator test to the central station. A communication failure will be indicated at the keypad by a system trouble “e03-fail to comm” display. Repeat the test to attempt to correct a communicatio...

  • Page 19

    19 k e y p ad f u n c t i o n s activate program? Activates the program mode from keypad no. 1. Note: this feature is disabled while armed. (see programming user codes) activate download? For installer's use only. If accidentally enabled, press c to exit. Note: this feature is disabled while armed. ...

  • Page 20

    20 your alarm specialist may have programmed your system to be monitored by a central station. The built- in digital communicator can transmit emergency signals and status reports to the central station 24 hours a day. Communicator features abort delay. Ask your installer which of your zones have ab...

  • Page 21

    21 ad v an c e d f e at u r e s security bypass/unbypass (security bypass programmed? ‰yes ‰no). In high-security applications, zones may be bypassed (or unbypassed) only if a valid code is entered first, as follows: 1. Enter a user code valid for bypass, then press b . 2. Press b then the zone numb...

  • Page 22

    22 p r o g r am m i n g ( o p t i o n a l ) enter the user program mode 1. Enter your user code, then press a to enter the function mode. 2. Answer no until “activate program y/n” is displayed, then press yes. “enter user code” will display indicating that the system is ready for user code programmi...

  • Page 23

    23 p r o g r am m i n g ( o p t i o n a l ) reviewing a programmed user code to review an existing user code, enter the user number and the corresponding user code will display. Exiting the user program mode when you have completed programming or erasing user codes, press c to exit the user program ...

  • Page 24

    24 p r o g r am m i n g ( o p t i o n a l ) enter the user program mode 1. Enter your user code, then press a to enter the function mode. 2. Answer no (press f ) until “activate program y/n” is displayed, then press yes ( e ). 3. “enter user code” will display, press next ( e ) and the keypad will d...

  • Page 25

    25 e n t e r z o n e d e s c r i p t i o n s - - " c e l l p h o n e s t y l e " press characters displayed in sequence hold g and press characters displayed in sequence 1 abc1 1 abc1 2 def2 2 def2 3 ghi3 3 ghi3 4 jkl4 4 jkl4 5 mno5 5 mno5 6 pqr6 6 pqr6 7 stu7 7 stu7 8 vwx8 8 vwx8 9 yz90 9 yz90 0 (s...

  • Page 26

    26 p r o g r am m i n g ( o p t i o n a l ) enter the user program mode 1. Enter your user code, then press a to enter the function mode. 2. Answer no (press f ) until “activate program y/n” is displayed , then press yes ( e ). 3. “enter user code” will display, press next ( e ) until the keypad dis...

  • Page 27

    27 k e y p ad m e s s ag e s the keypad can display the following functional messages. Other diagnostic messages are available for the installer or servicer. Should any unfamiliar messages appear, call your dealer for service. All zones operating; system can be armed. If displayed (gem-p9600/3200 pa...

  • Page 28

    28 k e y p ad m e s s ag e s alarm condition, followed by zone description(s). “alarm” and zones will display after system is disarmed. Note zones, then press c to clear keypad. (with pulsing sounder.) trouble condition on a fire zone. Press c to silence sounder. Correct trouble or call for service....

  • Page 29

    29 k e y p ad m e s s ag e s the system is in the process of reporting a cancel signal to central station which will cancel the alarm which it has just reported. The alarm signal has been cancelled during the abort delay (before an alarm signal report was sent to the central station). If cancelled a...

  • Page 30

    30 g l o s s ar y following are brief descriptions of terms and features used herein that may be unfamiliar to you. Some of the features are programmable options that may or may not apply to your particular system. Abort delay - a delay period that allows the control panel to be reset, thus aborting...

  • Page 31

    31 g l o s s ar y exit/entry delays - separate delays that let you exit and enter your premises without setting off an alarm when the system is armed. Interior button - bypasses interior zones on arming (see zones - interior zones). Instant protection - arming without entry delay using the f button ...

  • Page 32

    32 g l o s s ar y user code - your personalized code for arming and disarming the system. It may contain up to six digits. Zones - independent circuits that protect specific areas of the premises: auto-bypass zone: a zone that will be automatically bypassed from the protection system if it is in tro...

  • Page 33

    33 s y s t e m t r o u b l e e r r o r c o d e s your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a problem should occur, the sys tbl (system trouble) icon will display on the left side of keypad window along with one or ...

  • Page 34

    34 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e04-nn wireless transmitter supervisory failure a problem has been detected with a wireless transmitter. Call installing company for service. E05-nn wireless transmitter low battery the battery in a w...

  • Page 35

    35 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e10-nn keypad response failure call installing company for service. E11-nn keypad tamper a keypad has been removed from the wall. Call installing company for service if problem cannot be repaired. E12...

  • Page 36

    36 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e19-00 user program memory error call installing company for service. E20-00 dealer program memory error call installing company for service. E21-00 system shutdown call installing company for service...

  • Page 37

    37 s y s t e m t r o u b l e e r r o r c o d e s trouble indication system trouble condition action e40-00 rf self test failure a wireless motion sensor on the zone indicated has failed its automatic self test routine. Call installing company for service. E41-nn fire trouble a problem has been detec...

  • Page 38

    38 t r o u b l e s h o o t i n g what do i do if... For more info... I try to arm my system but the keypad just displays “zones not normal” and “can’t arm system” and beeps at me. If the green status light is off, a zone is open. Find and secure the open window or door. See page 6 i try to arm my sy...

  • Page 39

    39 n o t e s.

  • Page 40

    40 napco limited warranty napco security systems, inc. (napco) warrants its products to be free from manufacturing defects in materials and workmanship for thirty-six months following the date of manufacture. Napco will, within said period, at its option, repair or replace any product failing to ope...