NAPCO RPXP4GT Installation Instructions Manual - page 9
9
Full Setting the System with Automatic
Bypassing - Home/Away with Delay
Zones
From the Keypad
Press
C
B
to return protection to
Home/Away with Delay Zones
that have
been automatically bypassed. Three
minutes are allowed to walk through
Exit/
Entry
and
Exit/Entry Follower Zones
.
Using A Keyfob (GEM-KF)
All zones in the system can be armed
regardless of the state of the
Exit/Entry
Zone
when arming with a Keyfob and using
an AUX key programmed as
Full Set
. Press
K
and press and hold the
M
or
N
keys for 1.5s when leaving the premises. All
zones, including
Home/Away Zones
are
armed.
Bypassing a zone
Press the
C
key, then the zone number to be
bypassed. While the panel is DISARMED, the
bypassed zone LED will flash slowly; indicating
the zone has been bypassed. While the panel is
ARMED, the bypassed zones will only be
displayed if the
Display Bypassed
[21-3] option
has been selected.
Unbypassing a zone (Disarmed only)
Press the
C
key then the number of the
zone to be unbypassed.
Group Bypass
Press
C
C
to Bypass all
Exit/Entry
Follower Zones
[02] or
Home/Away Zones
[01] (only if the system is programmed
exclusively for
Home/Away with Delay
zones
).
Using A Keyfob (GEM-KF)
Hold the
M
or
N
key on the Keyfob to
Bypass all
Exit/Entry Follower Zones
[02] or
Home/Away Zones
[01] (only if the system is
programmed exclusively for
Home/Away
with Delay zones
).
User Program Mode
To prevent the loss of the User 1 Code, the
panel default program includes
User 1 Code
Lockout
[96-2].
To change the User 1 Code from its default
value of 1234, program the 4-digit User 1 Code
through Dealer Programming [95]. User 1 Arm/
Disarm code is also used to program User
Codes 2 - 4. By default, the User 1 code cannot
be re-programmed by the user.
If it is necessary to change the User 1 code, it
can be changed through downloading or Dealer
keypad programming. From Dealer Program
Mode, change the U
ser 1 Code Lockout
([96-2]
LED=OFF) to disabled.
Entering User Program Mode
1. Enter
A 8
2. Enter User 1 Code
(
1 2 3 4
)
(Default)