    W415-0721 / b / 05.03.11 1 installer: leave this manual with the appliance. Consumer: retain this manual for future reference. Installation and operating instructions 1.27 wolf steel ltd., 24 napoleon rd., barrie, on, l4m 0g8 canada / 103 miller drive, crittenden, kentucky, usa, 41030 phone (705)721...

  • Page 2: Table of Contents

    W415-0721 / b / 05.03.11 2 table of contents note: changes, other than editorial, are denoted by a vertical line in the margin. 1.0 installation overview 3 2.0 introduction 4 2.1 dimensions 5 2.2 specifications 5 2.3 general instructions 6 2.4 general information 6 2.5 california prop 65 7 2.6 ratin...

  • Page 3: 1.0 Installation Overview

    W415-0721 / b / 05.03.11 3 1.0 installation overview see the section “installation - chimney” see the section “eprs optional rear sheild installation” see the section “ep65 optional blower installation” see the section “ash fender installation” see the section “optional outside air installtion” see ...

  • Page 4: 2.0 Introduction

    W415-0721 / b / 05.03.11 4 2.0 introduction 3.17c ! Warning • this appliance is hot when operated and can cause severe burns if contacted. • any changes or alterations to this appliance or its controls can be dangerous and is prohibited. • do not operate appliance before reading and understanding op...

  • Page 5

    W415-0721 / b / 05.03.11 5 2.1 dimensions specifications model 1600c-1 width x depth 27.000" x 24.000" height 28.000" rear flue height 27.750" chamber (d.W.H.) 11.900" x 20.400" x 10.400" capacity (cubic feet) 1.460 ft³ app. Area heated * 600-1200 ft² heat output (high burn) ** 50,000 btu duration l...

  • Page 6: Warning

    W415-0721 / b / 05.03.11 6 2.3 general instructions • before beginning your installation, consult with your local building code agency or fi re offi cials and insurance representative to ensure compliance. • non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke...

  • Page 7: Aamp

    W415-0721 / b / 05.03.11 7 the 1600c-1 is designed to be operated with both the main and ash door closed. The heat produced is mainly transmitted through the window and the body of the appliance. Combus- tion occurs on the bottom of the combustion chamber with a draft entry through the top of the co...

  • Page 8: Warning

    W415-0721 / b / 05.03.11 8 3.0 pre-installation preparation have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review your installation plans and/or installation. Draw out a detailed plan of the installation including dimensions and verify the di...

  • Page 9: Warning

    W415-0721 / b / 05.03.11 9 for reduced clearances installation must comply with can/csa-b365 in canada or nfpa 211 in the united states. For clearances when installed with rear shield, see "eprs optional rear shield installation" section. Where passage through a wall, or partition of combustible con...

  • Page 10: Warning

    W415-0721 / b / 05.03.11 10 4.1 chimney ! Warning never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause fire. Do not connect this appliance to a chimney system s...

  • Page 11

    W415-0721 / b / 05.03.11 11 4.1.1 chimney connection this appliance must be connected to: a. A chimney complying with the requirements for type ht chimneys in the standard for chimneys, factory- built, residential type and building heating appli- ance, or b. A code-approved masonry chimney with a fl...

  • Page 12

    W415-0721 / b / 05.03.11 12 4.1.2 adding chimney sections add chimney sections, according to the manufacturers installation instructions. The chimney must extend at least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof, building or obstacle within 10 f...

  • Page 13

    W415-0721 / b / 05.03.11 13 4.1.3 typical through the ceiling a. Move the stove into position with the fl ue centered, midpoint between two joists to prevent having to cut them. Use a plumb bob to line up the center. B. Cut and frame an opening in the ceiling to provide a 2” clearance between the ou...

  • Page 14

    W415-0721 / b / 05.03.11 14 4.1.4 typical through the wall if possible, design the installation so that the connector does not pass through a combustible wall. If during your installation you must pass through a combustible wall, check with your building inspector before you be- gin. Also check with...

  • Page 15

    W415-0721 / b / 05.03.11 15 4.1.5 typical existing masonry 4.2 flue collar reversal the fl ue collar is oriented in the top exit position. Remove the two mounting bolts, and turn the collar 180 degrees. Secure the collar us- ing the same bolts, nuts and washers. You can also install your appliance u...

  • Page 16

    W415-0721 / b / 05.03.11 16 4.3 venting connect the appliance to a chimney system using a listed double wall connector with a minimum clearance rating of 12" or less. Use chimney sys- tem listed to ulc s629 in canada or ul 103ht in the usa. The chimney must be installed in accordance with the manufa...

  • Page 17: 5.0 Finishing

    W415-0721 / b / 05.03.11 17 to avoid damage during transport, the ash fender has been stored behind the main door. Pivot the ash fender onto tab “a” and lower into place. A 5.0 finishing ! Warning 5.1 door removal pivot the door open and lift the door and pins off the bushings. Set the door aside be...

  • Page 18

    W415-0721 / b / 05.03.11 18 5.3 heat shield installation the heat shield stored in the appliance must be installed under the appliance with the 2 provided screws. For reduced clearances installation must comply with nfpa 211 or can/csa-b365. A. Remove the 4 screws from the rating plate on the back o...

  • Page 19: Warning

    W415-0721 / b / 05.03.11 19 6.2 ep65 optional blower installation a. Ensure the thermal disc bracket is in the correct position. B. Install the blower and housing as shown using the 4 screws supplied. C. Loosen the thermal disc bracket (2 screws) and slide the bracket until the thermal disc is touch...

  • Page 20

    W415-0721 / b / 05.03.11 20 6.4 optional outside air kit installation and floor securing if possible connect the air intake at the bottom to the outside with a 4 inch (100mm) diameter fresh air kit available at your authorized dealer. Connecting the appliance’s air intake to the outside as well as s...

  • Page 21: Warning

    W415-0721 / b / 05.03.11 21 ! Warning 7.0 operation your napoleon® epa listed product is a hi-tech appliance, designed with the most advanced technology. The appliance is extremely airtight. It has an exclusive direct outside air supply (optional kit), a safety fea- ture designed to prevent spillage...

  • Page 22

    W415-0721 / b / 05.03.11 22 the appliance will emit a slight odour for a few hours. This is a normal temporary condition caused by the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to suffi ciently ventilate the room duri...

  • Page 23: Warning

    W415-0721 / b / 05.03.11 23 7.1 air control draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length and diameter of chimney, local geography, nearby obstructions and other factors. Adjusting the air control (item b) regu...

  • Page 24

    W415-0721 / b / 05.03.11 24 7.4.2 extended fire 83.1 a properly installed appliance should not smoke. If yours does, check the following: • has the chimney had time to get hot? • is the smoke passage blocked anywhere in the appliance, chimney connector or chimney? • is the room too airtight and the ...

  • Page 25: Warning

    W415-0721 / b / 05.03.11 25 ! Warning ! Warning it is essential to keep the grate free of a heavy build up of ashes. Remove the grate cover by inserting the tool into the grate cover handle and lifting. Brush ashes to the grate where they will drop into the ash pan. Replace the grate cover after ash...

  • Page 26

    W415-0721 / b / 05.03.11 26 8.2 creosote formation and removal 8.3 runaway or chimney fire 8.4 chimney cleaning 84.1 when wood is burned slowly, it produces tar and other organic vapours which combine with expelled moisture to form creosote. These vapours condense in the relatively cooler chimney fl...

  • Page 27: Warning

    W415-0721 / b / 05.03.11 27 if the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot fi re will clean the glass. The most common reasons for dirty glass include: not using suffi cient fuel to get the appliance thoroughly hot, using green or wet wood, clos...

  • Page 28

    W415-0721 / b / 05.03.11 28 8.7 wood 87.1b when loading the appliance, ensure that the upper fi bre baffl es are not forced out of position. For maximum effi ciency, when the appliance is thoroughly hot, load it fully to the top of the door opening and burn at a medium low setting. The whiteness of ...

  • Page 29: 9.0 Replacements

    W415-0721 / b / 05.03.11 29 9.0 replacements contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your authorized dealer / distributor. For warranty replacement parts, a photocopy of the original invoice will ...

  • Page 30

    W415-0721 / b / 05.03.11 30 components ref part number description 35 w105-0016 axle, ash pan door latch 36 w570-0125 screw door latch 37 w485-0033 hinge ash pan door 38 w485-0032 pin door latch 39 w135-0355 door, right side 40 w135-0356 door, left side 41 w485-0029 hinge pin door 42 w562-0053 gaske...

  • Page 31

    W415-0721 / b / 05.03.11 31 30 36 33 37 35 5 6 7 9 10 21 54 25 26 28 27 20 1 2 3 4 8 15 19 12 11 13 14 24 23 22 17 18 31 53 41 29 39 36 32 38 49 48 44 43 55 57 56 16 45 40 42 34 47 51 50 50 46 52.

  • Page 32: 10.0 Troubleshooting

    W415-0721 / b / 05.03.11 32 10.0 troubleshooting 42.14a ! Warning turn off the electrical power before servicing the appliance. Appliance may be hot, do not service until appliance has cooled. Do not use abrasive cleaners. When checking connections, installing jumper wires (for test purposes only) o...

  • Page 33: 11.0 Warranty

    W415-0721 / b / 05.03.11 33 11.0 warranty napoleon® warrants its products against manufacturing defects to the original purchaser only. Registering your warranty is not necessary. Simply provide your proof of purchase along with the model and serial number to make a warranty claim. Provided that the...

  • Page 34: 12.0 Service

    W415-0721 / b / 05.03.11 34 12.0 service history 43.1.

  • Page 35: 13.0 Notes

    W415-0721 / b / 05.03.11 35 13.0 notes 44.1.

  • Page 36

    W415-0721 / b / 05.03.11 36 44.1.