Summary of EPA 1100

  • Page 1

    1 w415-0512 /c 10.02.06 installer: these instructions must be conveyed to and remain with the homeowner. Wolf steel ltd., 24 napoleon rd., barrie, on l4m 4y8 canada • (705)721-1212 • fax(705)722-6031 www.Napoleonfireplaces.Com • ask@napoleon.On.Ca installation and operation instructions for hi-tech ...

  • Page 2

    2 w415-0512 / c 10.02.06 pg 2-4 introduction warranty general information care of plated & enamelled parts care of glass 5-6 installation installing the legs alcove installation stove installation chimney connection adding chimney sections outside air wall pass-through 6-7 mobile home venting outsid...

  • Page 3

    3 w415-0512 /c 10.02.06 napoleon products are manufactured under the strict standard of the world recognized iso 9001 : 2000 quality assurance certificate. Napoleon products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The co...

  • Page 4

    4 w415-0512 / c 10.02.06 except for their different depths, models 1100, 1150, 1400, 1900 and the fireplace inserts 1101, 1401, and 1402 are identical and use the same burning principles. They were specifically designed over many months of research to meet the 1990 u.S.A. Epa particulate emission st...

  • Page 5

    5 w415-0512 /c 10.02.06 if the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. It must be installed with a minimum height of 7’ between the stove base ...

  • Page 6

    6 w415-0512 / c 10.02.06 pedestal base 4.5" pedestal base floor area below st ove a" b" a (in.) b(in.) 1100 8 5/8" 9 3/4" 1400 11 1/8" 9 3/4" 1900 14 7/8" 9 3/4" if possible connect the air intake at the pedestal's back or bottom to the outside with a 4 inch (100mm) diameter fresh air kit available ...

  • Page 7

    7 w415-0512 /c 10.02.06 it must be installed between ceiling joists, with radiation shield and roof flashing, so that the structural strength, insula- tion and waterproof qualities of the home are not lessened. Seal with silicone to maintain a vapour barrier at the chimney and outside air pipe penet...

  • Page 8

    8 w415-0512 / c 10.02.06 in the united states:while it is not required, it is rec- ommended that a chimney liner be installed that is con- tinuous from the insert to the top of the chimney, particu- larly when the insert is installed in a basement. For this type of connection, use the "in canada" in...

  • Page 9

    9 w415-0512 /c 10.02.06 3. The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16" nut driver will be required to complete this job. Unplug wires from the thermal switch on the panel. See figure 15. 4. Remove the securing wingnut from the blower mounting bracket, slide th...

  • Page 10

    10 w415-0512 / c 10.02.06 1100/1100c/ 1101 1400/1400l 1401 1900 1100l/1150 4-#1 4-#1 4-#1 4-#1 4-#7* 2-#4 2-#4 2-#4 2-#4 2-#2 8-#1 8-#1 12-#1 12-#1 12-#7* 2-#3 2-#3 2-#3 2-#4 (notched) 2-#10 2-#10 2-#11 2-#11 2-#12 2-#13 3-#1 4-#1 5-#1 6-#1 7-#7* 2-#2 2-#2 2-#2 2-#2 2-#2 1-#5 1-#5 1-#5 1-#6 1-#6 1-#...

  • Page 11

    11 w415-0512 /c 10.02.06 with stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10. 1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall. Install the final course of bricks on the b...

  • Page 12

    12 w415-0512 / c 10.02.06 ash well cover rotate to close: folding handle rear rotate pull and to open: you can now add larger pieces of wood and operate the stove normally. Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chimney. There will be a bed of...

  • Page 13

    13 w415-0512 /c 10.02.06 a properly installed napoleon unit should not smoke. If yours does, check the following: has the chimney had time to get hot? Is the smoke passage blocked anywhere in the stove, chimney connector or chimney? Is the room too airtight and the air intake not connected to the ou...

  • Page 14

    14 w415-0512 / c 10.02.06 burn only dry, clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut wood contains about 50% moisture while after proper sea- soning only about 20% of the water remains. As wood is burned, this water boils off consuming en...

  • Page 15

    15 w415-0512 /c 10.02.06 # part no. Description 1 w325-0002 spring handle - small 2 w325-0007 spring handle - large 3* w090-0001 brick - # 1 4* w090-0002 brick - # 2 5* w090-0004 brick - # 4 left 6* w090-0005 brick - # 4 right 7* w090-0015 brick - # 7 8* w090-0018 brick - # 8 9* w090-0019 brick - # ...

  • Page 16

    16 w415-0512 / c 10.02.06 65 gs200-g ornamental trivet 66 ep62-1 variable speed blower 67* w500-0064 fresh air cover plate 68* 111kt outside air kit 69* w470-0002 enamel touch up & brush ( specify colour ) accessories 72 ak-1 adapter kit for cisk 73 ei-900k10 10" flashing kit c/w bull nose trim 69* ...

  • Page 17

    17 w415-0512 /c 10.02.06 59 15 16 18 17 19 16 57 2 32 12 10 14 30 33 74 31 44 84 83 73 72 76 63 64 z.P. Ins. Classb 115v 60hz 46w em3030l-167 zr-2 073 sel 81 66 1 46 77 40 38 39 58 65 55 56 48 49 85 47 52 53 54 62 31a 20

  • Page 18

    18 w415-0512 / c 10.02.06 w olf steel fir eplace ser vice histor y this fireplace must be serviced annually depending on usage. Date service t echnician name service performed special concerns dealer name.

  • Page 19

    19 w415-0512 /c 10.02.06 notes.

  • Page 20

    20 w415-0512 / c 10.02.06 notes.