Summary of GVF36N

  • Page 1

    1 w415-0297 / k / 11.20.07 installer: these instructions must be conveyed to and remain with the homeowner. Wolf steel ltd., 24 napoleon rd., barrie, on l4m 4y8 canada • (705)721-1212 • fax(705)722-6031 www.Napoleonfireplaces.Com • ask@napoleon.On.Ca certified under american national standards, ansi...

  • Page 2

    2 w415-0297 / k / 11.20.07 pg 3-4 introduction warranty general instructions general information care of glass door, catalytic tiles & plated parts 5-7 installation combustion and ventilation air provisions determining confi ned or unconfi ned space gas installation optional wall switch installation d...

  • Page 3

    3 w415-0297 / k / 11.20.07 ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® ® the following materials and workmanship in your new napoleon® gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and ember...

  • Page 4

    4 w415-0297 / k / 11.20.07 use only accessories designed for and listed with your specifi c fi replace. Early signs of carbon monoxide poisoning resem- ble the fl u, with headache, dizziness and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have he...

  • Page 5

    5 w415-0297 / k / 11.20.07 room 2 room 1 this heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with...

  • Page 6

    6 w415-0297 / k / 11.20.07 proceed once the vent installation is complete. Note: all gas connections must be contained within the fi replace when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base. 2. The fi replace is design...

  • Page 7

    7 w415-0297 / k / 11.20.07 to install the fireplace face flush with the finished wall, position the framework to ac- commodate the thickness of the fi nished wall. Bend out the four nailing tabs, attached on either side of the fi replace and secure to the 2x4 framing. The tabs will facilitate the inst...

  • Page 8

    8 w415-0297 / k / 11.20.07 the curtain mesh must be kept fully closed during operation to help prevent accidental burns from occurring. The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate. Remove the backing of the logo supplied and place o...

  • Page 9

    9 w415-0297 / k / 11.20.07 a c b figure14 hood attach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. A clips centre slot flange upper louvres insert the louvre tabs into the slots located at the top left and right...

  • Page 10

    10 w415-0297 / k / 11.20.07 figure 22 figure 20 attach the connectors from the black and red wires to the blower. Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle. The wire harness provided in this kit is a universal harness. When installe...

  • Page 11

    11 w415-0297 / k / 11.20.07 when lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. Stop! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the fi replace. 4. Open the c...

  • Page 12

    12 w415-0297 / k / 11.20.07 this procedure must be performed by a qualified service person! Inspect the pilot for any visible contamination or debris (usually lint, pet hair, spider webs, carpet fi bre, etc.) and remove. Disconnect the pilot from the pilot tubing line. Using a 7 / 16 ” wrench, remove...

  • Page 13

    13 w415-0297 / k / 11.20.07 contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. M odel & s erial n umber of ...

  • Page 14

    14 w415-0297 / k / 11.20.07.

  • Page 15

    15 w415-0297 / k / 11.20.07 main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - service or replace oxygen depletion sensor system - correct piping and/or regulator to provide correct pressure thermopile shorting - clean thermopile connection to t...

  • Page 16

    16 w415-0297 / k / 11.20.07 white / grey film forms on the glass of the optional cata- lytic door. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a recommended gas fi replace glass cleaner. Do not clean glass when hot. If deposits are not ...

  • Page 17

    17 w415-0297 / k / 11.20.07 w olf steel fir eplace ser vice histor y this fi replace must be serviced annually depending on usage. Date service t echnician name service performed special concerns dealer name.

  • Page 18

    18 w415-0297 / k / 11.20.07 notes.