Napoleon NH23 User Manual - page 5
OPERATING INSTRUCTIONS
Airflow direction control
Adjust the air flow direction properly otherwise it
might cause discomfort or cause uneven room
temperatures.
Adjust the horizontal/vertical louver using the remote
controller. For some models, the vertical louver can
only be adjusted manually.
Perform this function while the unit is in operation.
Use the remote controller to adjust the air flow direction.
The vertical/horizontal louver changes 6 degree in angle
for each press, or swing up and down automatically.
Please refer to the REMOTE CONTROLLER OPERATION
MANUAL
for details.
To set the horizontal/vertical air flow direction
For some models, the vertical louver can only be adjusted
manually. Move the deflector rod manually to adjust the air
flow in the direction you prefer.
:Do not put your fingers into the panel of
blower and suction side.
IMPORTANT
The high-speed fan inside may
cause danger.
Do not operate the air conditioner for long periods with
the air flow direction set downward in cooling or
dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
moisture to drop on to the floor or on furnishings.
When the air conditioner is started immediately after it
was stopped, the horizontal louver might not move for
approximately 10 seconds.
Open angle of the horizontal louver should not be set
too small, as COOLING or HEATING performance may
be impaired due to too restricted air flow area.
Do not move the horizontal louver manually, otherwise
the horizontal louver will be out of sync. Please cease
operating, unplug power for a few seconds,then restart
the air conditioner.
Do not operate unit with horizontal louver in closed
position.
CAUTION
,,
,,
Manual operatio n can be used temporarily in case the remote controller is dis able or
the unit requires mainten ance.
OPERATING INSTRUCTIONS
Manual operation
NOTE: This manual does not include Remote Controller Operations, se e the
> packed with the unit f or details.
Operating temperature
Open and lift the front panel up to an angle
until it remai ns fi xed wit h a click ing sound.
For some model s, please use suspensi on
bars to prop up t he p anel.
Close the panel firmly to its original
posit ion.
One pres s of the manual control button will
lead to the forced AU TO operati on. If press
th e button twice within five seconds, the unit
will operate unde r forced COOL operation.
This button is used for testing purposes
only. You had better not choose it.
To restore t he remote c ontroller operation,
use the remote control ler direc tly.
CAUTION:
1
3
2
●
●
NOTE: T he unit must be turned off before
operatin g the ma nual control butt on. If the
unit is operation al, contin ue pres sing the
manual control b utton un til the un it is off.
Mode
Temper ature
Room temperature
Outdoor tempera ture
1. Optimum perform ance wil l be achieved within these operating temper atures.If air
conditioner is used outside of the above conditions, certain safety protection features
might come into o peration and cause the unit to func tion abnormally.
2. Room re lative humidity less than 80%. If the air conditioner operates in excess of this
figure, the surface of the air conditioner may attract condensation. Please sets the verti cal
air flow louver to i ts maxim um angl e (vertically to the floor), and set HIGH fan m ode.
Suggestion: For the unit ad opts an E lectric Heater, w hen the outside ambient t emperature
is below 0 C(32 F), we strongly recommend you to keep the m achine plugged in order to
guarantee it running smoothly.
O
O
NOTE:
Cooling op eration
Heating operation
Drying op eration
17
62
-15
50
5
122
For the models with low
temperature cool ing syste m
0
50
32
122
30
86
-15
30
5
86
10
50
0
50
32
122
Deflec tor ro d
R ange
Range
Manual control
button
A UTO/CO OL
Suspension bars
AUTO/COOL
( )
1
( )
2
Manual control
button