Before operating the pump, bleed any air from the
system by loosening the thermometer.
Troubleshooting
WPT 480/P
WPT 600/P
WPT 720/P
Pump overheats
•
Inlet water temperature too high
•
Inadequate water flow
•
No oil in pump
•
Oil adjustment set too lean
•
RPM too fast
•
Prolonged operation
Too much oil use
•
Oil adjustment set too rich
•
Oil seals defective
•
Cracked pump body
Pump doesn’t turn
•
Broken vane
•
Frozen
•
Pump endplate bolts too tight
•
Faulty PTO or drive set up
No vacuum or pressure in tank
•
Suction valve in neutral
•
Defective seal or vanes
•
Pump not driven fast enough
•
Check valve or suction line clogged