Naturally Filtered MG-10 User Manual - page 3
Plugthecontrolvalveintoan
approvedGFIpoweroutletus-
ingthesuppliedelectricalcord;
operationintheserviceposition
beginsautomatically.
YourMG-10issetatthefactory
defaultsettingsnotedbelow.
Youcaneithercheckorchange
thesettingsbyfollowingthese
instructions.
Note:Displaywillcycleevery5to
10secondsbetweentheTimeand
numberofdaysuntilthenextregen-
erationcycle.Thisisnormal.
1.EnterTimeofDaymode(TDonleftside)by
pressingeithertheUporDownarrow,andcon-
tinueuntildisplayreads12:01PM.
2.PressExtraCyclebuttonORleavedisplayidle
fortensecondsandTimeofDaymodewillbe
exited.
3.Whiletimereads12:01PM
press&hold
both
theUpandDown
arrowsuntildisplaychangesto
(DFGAL).Youarenowinprogrammingmode.
1.Displayshouldread(DFGAL)
DF = Display Format / GAL = Gallons
2.Displayshouldread(VTFLtr)
VT = Valve Type / FLtr = Filter
3.Displayshouldread(CTtc)
CT = Control Type / tc = Time Clock
4.Displayshouldread(NT---1)
NT = Number of Tanks / 1 = One
5.Displayshouldread(DO4)
DO = Day Override (days between regeneration)
Note:Regenerationevery4daysisthemaximumrecommendedinterval.Yoursource
watermayrequireregerationcyclestobeperformedmoreoften.
6.Displayshouldread(RT3:00)
RT = Regeneration Time / 3:00 = 3 AM
Note:Thissettingrepresentsthetimeofdayinwhichtheregenerationcyclewilloccur.
Adjustifdesired.
7.Displayshouldread(BW15)
BW = Backwash / 15 = Fifteen Minutes
8.Displayshouldread(BD0)
BD = Brine Draw / 0 = Zero Minutes
9.Displayshouldread(RR5)
RR = Rapid Rinse / 5 = Five Minutes
Note:WhenExtraCyclebuttonispressed,ProgrammingModewillbeexited.
Displaywillreverttonormaloperation.Adjustthetimeofdaytoyourcurrentlocal
timeusingtheUporDownarrows.
Programmingisnowcomplete.
Foreachstepbelow,pressthe
UporDownarrowuntilthedisplay
matchesthestep’simage.
Proceedtoeachnextstepbypressingthe
ExtraCyclebuttononce.
ProgrammingMode-GeneralInstructions
EnteringProgrammingMode
PowerFailure:
Intheeventofpowerfailure,thecontrolvalvewillcontinuetokeep
time for 48 hours. All programming is saved indefinitely. When power is restored,
DataDisplay will flash indicating power interuption. Pressanybuttonanddisplay
will stop flashing.
ManualRegeneration:
To manually regenerate filter,
press&holdtheExtraCycle
buttonfor10seconds.
5
6
MG-10 Control Valve Master Programming