II. Best Outdoor Boiler Burn Practices
Read and follow all operating instructions.
A.
Fuel Used: You may burn any seasoned hardwood. A well seasoned piece of wood will feel
significantly lighter than one of the same type and size with higher moisture content. Higher moisture
contents will result in reduced burn times as heat will be used up drying out the moisture for the wood
to burn. Never burn driftwood, painted, stained or pressure treated wood. Do not burn trash, plastics,
gasoline, rubber, naphtha, household garbage, material treated with petroleum products (particle board,
railroad ties and pressure treated wood), leaves, paper products or cardboard.
B.
Loading Wood: Keep wood covered and store outside of clearance area listed on page 4. For a more
efficient burn, always add wood before the previous load has burned out. Most often the boiler can be
loaded in the morning and at night. Burn times vary from 6-24 hours depending on fuel being used,
installation, temperatures maintained and size of area being heated. Nature’s Comfort makes no
guarantees on burn times as there are too many variables outside of its control.
C. Starting fire: Do not use combustible fluids or chemicals. Use small pieces of split kindling together
with crumbled newspaper and add larger pieces. Remember: The smaller the better, the dryer the
better.
D. Location: It is recommended that the boiler be located with due consideration to the prevailing wind
direction. The chimney is 6” steel and can be easily extended with standard 6” stovepipe. Install
supports as directed by pipe manufacturer.
1 We recommend a distance of at least 100 feet be kept if prevailing winds blow towards any other
residence not served by the boiler, it is recommended that the stack be at least 2 feet higher than
the peak roof line of that residence.
2 If located more than 100 feet but no more than 150 feet to any residence, it is recommended that
the stack be at least 50% of the peak roof line of that residence, plus an additional 2 feet.
3 If located more than 150 feet but no more than 200 feet to any residence, it is recommended that
the stack be at least 25% of the height of the peak roof line of that residence, plus an additional 2
feet.
Chimney height relative to nearest downwind neighbor
Always remember to comply with all applicable state and local codes and laws.