3. Before proceeding further, carefully check that cable you have just connected the positive
terminal of inverter to the positive terminal of the power source.
4. Connect the cable securely from the negative terminal of inverter to the negative terminal of the
power source.
5. Set the power switch to the ON position. Check the power and RUN / GREEN POWER LED
indicators on the front panel of the inverter source. If the LED is not lit, check your power source
and the connections to inverter. The other indicators should be off.
6. Set power inverter switch to the OFF position. The indicator lights may blink and the internal
alarm may sound momentarily. This is normal.
Plug the test load into the AC receptacle on the front panel of the inverter. Leave the test load
switch off.
7. Set power inverter switch to the ON position and turn the test load on. The inverter should supply
power to the load. If you plan to measure the output voltage of the inverter, a meter such as
FLUKE 45, BECKMAN or other Digital Volt meter must be used.
WARNING!
You may observe a spark when you make this connection. Do not
make this connection in the presence of flammable fumes.
Explosion or fire may result.
CAUTION!
Reversed polarity connections will blow a fuse in inverter and may
permanently damagethe inverter.
Damage caused by a reverse polarity connection is not
covered by our warranty.
+
-
WARNING!
Make sure all the DC connections are tight (torque to
9-10 ft-lbs,11.7-13Nm). Loose connections will
overheat and could result in a
fire