    ====================================================================== control commands for nec projector (basic) rev 11.03.11a copyright (c) nec display solutions, ltd. 2002-2011 ---------------------------------------------------------------------- updated on november 03, 2011 --------------------...

  • Page 2

    ====================================================================== contents 1. Projector control 2. Connection method 3. Interface conditions 4. List of commands 5. Command descriptions 6. Table of response error codes ====================================================================== 1. Pro...

  • Page 3

    [p350x/p350w/p420x series] standby mode: "power-saving" control command serial port wired lan port wireless lan unit power on yes no no yes: supported no: not supported ==================================================================== 3. Interface conditions --------------------------------------...

  • Page 4

    (1) (2) (3-1) (3-2) (3-3) (3-4) gt5000/gt6000 yes yes yes yes yes no gt1150/gt2150 yes no yes yes yes no ht410/ht510 yes no no no no no ht1000/ht1100 yes no no no no no lt180 yes no no no no no lt25/lt30/lt35 yes no no no no no lt220/lt240/lt260 yes no yes yes no no lt240k/lt260k yes yes yes yes no ...

  • Page 5

    ( caution ) before making connections, set the standby mode of the projector to "normal" or "idol mode". The projector cannot use the control commands in the power-saving condition, but the following model can use some control commands. [p350x/p350w/p420x series] standby mode: "power-saving" control...

  • Page 6

    [ gt/lt80/mt/np1000/vt (except vt70/vt80/vt90)/np3150/np905/np600/np4000/np3250/np610/np2200/np216/m300/p420/u300/v300 ] the pc control connector is a d-sub 9-pin connector. 1 2 to txd of pc 3 to rxd of pc 4 5 to gnd of pc 6 7 to cts of pc 8 to rts of pc 9 ===========================================...

  • Page 7

    This is an identification data assigned to each command. Command : this sets an identification data assigned to each command to send it. ( see each command description.) response : this returns the 6th bit of received id1 as high. For ack it sends the 8th bit back as low (recognized); for nak it sen...

  • Page 8

    * when the controller is connected with the projector on a one-to-one basis broadcast notification is recommended. * when the controller is connected with multiple projectors to control a certain projector, use "individual notification". For all others "broadcast notification" is recommended. Respon...

  • Page 9

    4-2. Data portion of response ********************************************************************** for ack this returns ack without adding data portion to the command that does not request data. This returns ack with adding data to the data portion for the command that requests data. For nak this ...

  • Page 10

    02h : adjustment failed * when a logo transfer error occurs 00h : start is not requested 01h : cannot process due to storing 02h : exceeds the total number of blocks required at the time of start 03h : the block number of transferred data is not consecutive. Usb connection --------------------------...

  • Page 11

    ==================================================================== 4. List of commands ---------------------------------------------------------------------- * example for command ---------------------------------------------------------------------- command name example --------------------------...

  • Page 12

    05 : mt860 06 : wt600/wt610/wt615 07 : gt5000 08 : lt240k/lt260k 09 : gt6000 10 : ht1100 11 : vt770 12: ht410/ht510 (ht10 series) 13 : lt245/lt265 14 : lt280/lt380 15 : lt180 16 : vt37/vt47/vt470/vt57/vt570/vt575/vt670/vt676 (vt70 series) 17 : vt48/vt480/vt580 (vt80 series) 18 : np1000/np2000 (np100...

  • Page 13

    Meaning of symbols -------------------------------------------------------------------- * supported ! Is available depending on model's version - not supported command name 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 006. Running sense * * * * * * * * * * * * * * * 007. Common data request * * * * ...

  • Page 14

    Command name 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 28 006. Running sense * * * * * * * * * * * - * * - - - * * - - - * * * 007. Common data request * * * * * * * * * * * - * * - - - * * - - - * * * 009. Error status request * * * * * * * * * * * * * * - - - * * * * * * * * 0...

  • Page 15

    In case of np216 series 20h in case of v300 series 20h in case of vt series 40h in case of np600 series 40h in case of np610 series 40h in case of np2200 series 40h in case of m300 series 40h in case of p420 series 40h in case of gt series 50h in case of ht series 60h in case of wt series 70h in cas...

  • Page 16

    Data01 status of operation bit 7: power on/off processing 0 = no execution (normal condition) 1 = during execution bit 6: selecting signal processing 0 = no execution (normal condition) 1 = during execution bit 5: cooling processing 0 = no execution (normal condition) 1 = during execution bit 4: ext...

  • Page 17

    00h: idling 01h: power on data05 cooling processing 00h: no execution (normal condition) 01h: during execution data06 indication signal number (entry list number - 1) 0 .. 199 data07 type 1 of input terminal to be selected (!) 01h : 1 02h : 2 03h : 3 04h : 4 05h : 5 data08 type 2 of input terminal t...

  • Page 18

    Data32 freeze status (!2) 00h : off 01h : on ffh : not supported data33 test pattern display 1 00h : no display (normal condition) 00h other : displaying (pattern id) pattern id pattern name mt lt lt180 lt80 ht gt w t vt np1000 np3150 np905 np4000 np4100 np62 np64 np3250 np216 p420 v300 02h cross ha...

  • Page 19

    Data68 selecting signal processing 00h : no execution (normal condition) 01h : during execution data69 status of operation 00h : idling 04h : power on 05h : cooling 06h : idling (error occurrence) other than above: (nondisclosure) internal use of code during a state transition period data70 .. 71 pr...

  • Page 20

    Data01 data70 data71 01h 00h 03h mt1060/mt1065 01h 01h 03h mt860 01h 02h 03h mt1075 01h 00h 06h np1000/np2000 02h 00h 03h lt240/lt260 02h 01h 03h lt220 02h 02h 03h lt240k/lt260k 02h 00h 05h lt245/lt265 02h 00h 06h lt380 02h 01h 06h lt280 03h 00h 04h vt770 03h 00h 06h vt80 series 03h 00h 07h vt90 ser...

  • Page 21

    Data72 pc card insertion 00h : not inserted 01h : inserted data73 usb mouse connection 00h : not connected 01h : connected data74 entry list type 01h : default 02h : user data75 .. 82 reserved data83 on-screen mute 00h : off 01h : on data84 reserved data85 indicate contents 00h = picture signal disp...

  • Page 22

    009. Error status request ********************************************************************** function: this command acquires the error information occurring with the projector. Command: 00h 88h 00h 00h 00h 88h response: at the time of a success 20h 88h 01h xxh 0ch data01 .. Data12 cks (*1) (*2) ...

  • Page 23

    Supplement: (!) lt/lt80/ht: "none" 015. Power on ********************************************************************** function: this command switches on the main power of the projector. Command: 02h 00h 00h 00h 00h 02h response: at the time of a success 22h 00h 01h xxh 00h cks (*1) (*2) (*3) respo...

  • Page 24

    Data02 switching number --------------------------------------------------------- when the switching object is the "signal list", the signal list number is specified. (0…99) --------------------------------------------------------- when the switching object is the "input connector", the input connec...

  • Page 25

    Response: at the time of a success 22h 03h 01h xxh 01h data01 cks (*1) (*2) (*3) data portion contents ------------------------------------------------------------------- data01 results 00h : normal ffh : error response: at the time of a failure a2h 03h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (...

  • Page 26

    022. Sound mute on ********************************************************************** function: this command mutes the sound. Command: 02h 12h 00h 00h 00h 14h response: at the time of a success 22h 12h 01h xxh 00h cks (*1) (*2) (*3) response: at the time of a failure a2h 12h 01h xxh 02h data01 d...

  • Page 27

    025. Onscreen mute off ********************************************************************** function: this command cancels the blanking of the on-screen display. Command: 02h 15h 00h 00h 00h 17h response: at the time of a success 22h 15h 01h xxh 00h cks (*1) (*2) (*3) response: at the time of a fa...

  • Page 28

    Data03 : 00h (direct settings) 01h (increment/decrement) data04 : lower data (8bit) data05 : upper data (8bit) ex.1) volume direct setting (value = 20) data01 : 05h (volume) data02 : 00h ("volume" only) data03 : 00h (direct setting) data04 : 14h (lower data : 20 = 0014) data05 : 00h (upper data : 20...

  • Page 29

    ------------------------------------------------------------------- data01 .. 02 results 0000h : normal 0000h other : error response: at the time of a failure a3h 10h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3) command example: * setting volume to "10" 03h 10h 00h 00h 05h 05h 00h 00h 0ah 00h 2...

  • Page 30

    Data04 data05 aspect ratio 4:3 (window) 00h 00h aspect ratio normal / auto (np600, np610, np2200, np62, np64, np216, p420, pa600, u300, v300 series) 00h 00h aspect ratio 1.25:1(5:4) 00h 00h aspect ratio letter box (pa600, px750 series) 01h 00h aspect ratio 1.33:1(4:3) 01h 00h aspect ratio wide zoom ...

  • Page 31

    Supplement: (!) lamp hour meter this is the timer for normal lamp mode conversion. Lamp timer acquisition examples data83 data84 data85 data86 : lamp timer 00h 00h 00h 00h : total 0 seconds c0h 65h 52h 00h : total 5400000 seconds/3600 = 1500 hours 00h e4h 57h 00h : total 5760000 seconds/3600 = 1600 ...

  • Page 32

    2) punch in data12 data11 data10 data09 (006ddd00) 3) change from hex to decimal - value will change to 7200000 seconds lamp remaining time (in terms of normal mode values) = (7200000 - 10800) / 3600 = 1997 hour 037-2. Lamp information request 2 ******************************************************...

  • Page 33

    To appear (in terms of eco mode values) 10h : remaining time until inhibition of lamp usage (in terms of specified values) 11h : remaining time until inhibition of lamp usage (in terms of normal mode values) 12h : remaining time until inhibition of lamp usage (in terms of eco mode values) response: ...

  • Page 34

    Function: this command acquires the information on the projector lamp. Command: 03h 9bh 00h 00h 03h data01 data02 data03 cks (*3) data portion contents ----------------------------------------------------------------- data01 target 00h : lamp1 01h : lamp2 data02 unit(!4) 00h : second 01h : reserved ...

  • Page 35

    Lamp use warning starting time 2000[h] model. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) lamp hour meter this is the timer for normal lamp mode conversion. (!3) lamp usage time this is the lamp total usage. It is displayed in the projector's menu. (!4) this setting is ignored, if the item's unit i...

  • Page 36

    00h : normal 01h : error response: at the time of a failure a3h b1h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3) 046. Wxga mode setting request ********************************************************************** function: this command acquires the setting of the wxga mode of projector. Comma...

  • Page 37

    01h : error response: at the time of a failure a3h b1h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3) ====================================================================== 6. Response ---------------------------------------------------------------------- * at the time of a success( ack ) this re...

  • Page 38

    Key number data01 data02 key name -------------------------------------------- 1 01h 00h power 2 02h 00h power on (!!) 3 03h 00h power off (!!) 4 04h 00h source (auto) (!!) 5 05h 00h auto (!) (!!) 6 06h 00h menu (!!) (!!!) 7 07h 00h up (!!) (!!!) 8 08h 00h down (!!) (!!!) 9 09h 00h right (!!) (!!!) ...

  • Page 39

    81 51h 00h s-video1 (!!) 82 52h 00h s-video2 83 53h 00h digital1 84 54h 00h digital2 85 55h 00h pc card 96 60h 00h bs 132 84h 00h volume up (!!) 133 85h 00h volume down (!!) 134 86h 00h keystone up (!!) 135 87h 00h keystone down (!!) 136 88h 00h slide up 137 89h 00h slide down 138 8ah 00h freeze (!!...

  • Page 40

    Command example: * sending the auto key code 02h 0fh 00h 00h 02h 05h 00h 18h * sending the auto (short) key code 02h 0fh 00h 00h 02h ddh 00h f0h ------------------------------------------ * cycle/toggle volume mute * cycle/toggle picture mute * cycle/toggle picture freeze 02h 0fh 00h 00h 02h data01 ...

  • Page 41

    051. Carbon savings information request ********************************************************************** function: this command acquires the carbon saving values on the projector. Command: 03h 9ah 00h 00h 01h data01 cks (*3) data portion contents -----------------------------------------------...

  • Page 42

    ------------------------------------------------------------------- data01 target 00h : use point on signal change 01h : picture mute during lens shift data02 setting value 00h : inactive 01h : active response: at the time of a success 22h 21h 01h xxh 02h data01 data02 cks (*1) (*2) (*3) data portio...

  • Page 43

    Data09 current value (upper ranking 8 bits) data10 .. 13 reserved response: at the time of a failure a3h 04h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3) (! ) acquirement items data01 data02 acquirement name 00h 00h picture / brightness 01h 00h picture / contrast 02h 00h picture / color 03h 00h...

  • Page 44

    4ch 07h color correction / yellow 4ch 08h color correction / magenta 4ch 09h color correction / cyan 4ch 0ah color correction / white 4dh 00h through 4eh 00h ref. Auto white / color temp r 4eh 01h ref. Auto white / color temp g 4eh 02h ref. Auto white / color temp b 4fh 00h position 50h 00h screen p...

  • Page 45

    077. Mute control ********************************************************************** function: this command controls the mute of picture, sound and on-screen. Command: 02h 1ah 00h 00h 02h data01 data02 cks (*3) data portion contents ---------------------------------------------------------------...

  • Page 46

    Data01 data02 data03 current models 08h 00h 10h np4100 08h 01h 10h np4100w 11h 00h 12h np64 11h 03h 12h np43 13h 01h 10h m300x 13h 02h 10h m300w 13h 05h 10h m260x 13h 06h 10h m260w 13h 00h 11h p420x 13h 01h 11h p350x 13h 02h 11h p350w 14h 02h 10h u300x 14h 04h 10h u310w 15h 00h 10h pa600x 15h 01h 10...

  • Page 47

    Legacy models 01h 00h 03h mt1060/mt1065 01h 01h 03h mt860 01h 02h 03h mt1075 01h 00h 06h np1000/np2000 02h 00h 03h lt240/lt260 02h 01h 03h lt220 02h 02h 03h lt240k/lt260k 02h 00h 05h lt245/lt265 02h 00h 06h lt380 02h 01h 06h lt280 03h 00h 06h vt80 series 03h 00h 07h vt90 series 04h 00h 01h gt1150 04...

  • Page 48

    Data05 calendar function 00h : no function 01h or 03h : timer function, sleep timer function 02h : sleep timer function data06 .. 32 reserved response: at the time of a failure a0h 85h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3) 078-2. Running status request ***********************************...

  • Page 49

    (*1) (*2) (*4) (*3) 078-3. Input status request ********************************************************************** function: this command acquires the status of input signal of the projector. Command: 00h 85h 00h 00h 01h 02h 88h response: at the time of a success 20h 85h 01h xxh 10h data01 .. Da...

  • Page 50

    01h : displaying data07 ..08 reserved data09 indicate contents 00h = picture signal displaying 01h = no signal 02h = viewer displaying 03h = test pattern displaying 04h = lan displaying data10 .. 16 reserved response: at the time of a failure a0h 85h 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3)...

  • Page 51

    078-5. Model name request ********************************************************************** function: this command acquires the model name of the projector. Command: 00h 85h 00h 00h 01h 04h 8ah response: at the time of a success 20h 85h 01h xxh 20h data01 .. Data32 cks (*1) (*2) (*3) data porti...

  • Page 52

    Function: this command controls the freeze. Command: 01h 98h 00h 00h 01h data01 cks operation types data01: 00h : reserved 01h : freeze start 02h : freeze cancel response: at the time of a success 21h 98h id *0h 01h data01 cks data portion contents ---------------------------------------------------...

  • Page 53

    Data portion contents ------------------------------------------------------------------- data01 c5h fixed data02 acquisition object 00h : mode 01h : position 02h : source response: at the time of a success 23h b0h 01h xxh 03h data01 data02 data03 cks (*1) (*2) (*3) data portion contents -----------...

  • Page 54

    If data02 is source(02h) 00h : off 01h : video 02h : s-video response: at the time of a success 23h b1h 01h xxh 03h data01 data02 data03 cks (*1) (*2) (*3) data portion contents ------------------------------------------------------------------- data01 00h fixed data02 update target ( same as data02...

  • Page 55

    111. Auto adjust execute2 ********************************************************************** function: this command executes the auto adjust. Command: 03h bah 00h 00h 01h 00h beh response: at the time of a success 23h bah 01h xxh 01h 00h cks (*1) (*2) (*3) response: at the time of a failure a3h ...

  • Page 56

    Data02 data03 data13 data14 current models 03h 08h 00h 10h np4100 03h 08h 01h 10h np4100w ffh 11h 00h 12h np64 ffh 11h 03h 12h np43 ffh 13h 01h 10h m300x ffh 13h 02h 10h m300w ffh 13h 05h 10h m260x ffh 13h 06h 10h m260w ffh 13h 00h 11h p420x ffh 13h 01h 11h p350x ffh 13h 02h 11h p350w ffh 14h 02h 10...

  • Page 57

    Legacy models 00h 01h 00h 03h mt1060/1065 00h 01h 02h 03h mt860 00h 01h 02h 03h mt1075 00h 01h 00h 06h np1000/np2000 00h 02h 00h 03h lt240/lt260 00h 02h 01h 03h lt220 00h 02h 02h 03h lt260k 00h 02h 00h 05h lt245/lt265 00h 02h 00h 06h lt380 00h 02h 01h 06h lt280 02h 02h 00h 05h lt180 02h 02h 00h 06h ...

  • Page 58

    Data15 ... 16 reserved response: at the time of a failure a0h bfh 01h xxh 02h data01 data02 cks (*1) (*2) (*4) (*3) 305-3. Projector information request ********************************************************************** function: this command acquires basic operation states of projector. Command...

  • Page 59

    0ch : digital2 0dh : scart 10h : auto ffh : not source input other : not support data06 indication signal type (effective only when select source input type 2 is 02h or 03h) x0h : ntsc3.58 x1h : ntsc4.43 x2h : pal x3h : pal60 x4h : secam x5h : b/w60 x6h : b/w50 x7h : palnm x8h : ntsc3.58 lbx x9h : n...

  • Page 60

    ====================================================================== 6.1. Response ---------------------------------------------------------------------- * at the time of a success (ack) this returns ack without adding data portion to the command that does not request data. This returns ack with a...