North Storm NS-14B-AC User Manual

Manual is about: 4-in-1

Summary of NS-14B-AC

  • Page 1

    1 north storm 4-in-1 air conditioner user manual ns–14b-ac ns-14w-ac models.

  • Page 2: Introduction

    2 introduction thank you and congratulations on your purchase of your north storm ™ portable ac unit. Please read this manual before operating this appliance. Warning if the information in this manual is not followed exactly, an electric shock or fire may result causing property damage, personal inj...

  • Page 3: Table of Contents

    3 table of contents safety awareness……………………………………………………..............…………..4 name of parts……………………………….………………………...............…….……..5 accessories………………………………………………..………..............……..…….... 6 introduction to panel and remote controller………………..………..………..7 operation introduction…………………………………………....

  • Page 4: Safety Awareness

    4 safety awareness ● do not use the unit on a socket under repairs or not installed properly. ● do not use the unit, follow these precautions: ◦ near to source of fire. ◦ an area where oil is likely to splash. ◦ an area exposed to direct sunlight. ◦ an area where water is likely to splash. ◦ near a ...

  • Page 5: Name of Parts

    5 name of parts north storm 1 2 4 3 5 8 7 6 side view 1. Rear cover 2. Air inlet 3. Front cover front view 4. Operation panel 5. Castor rear view 6. Power cord 7. Air inlet 8. Drain plug fig. 1.

  • Page 6: Accessories

    6 accessories north storm main ac unit hot-air exhaust hose hose connector (window end) hose connector (ac end) window kit remote controlle r fig. 2 speed temp+ mode temp- timer po we r.

  • Page 7: Control Panel

    7 control panel fig. 3 wf po we r bu tt on teperature+ bu tt on teperature- bu tt on signal receiver window operation mode bu tt on fan spped adjustment bu tt on timer on/off bu tt on high power temp+ temp- mode speed timer lo wt imer cool dehumf an heat.

  • Page 8: Remote Controller

    8 remote controller fig. 4 speed temp+ mode temp- timer po we r power : on/off switch mode : mode selector timer : hourly programming speed : fan speed selector temp+ : temperature selector up temp- : temperature selector down.

  • Page 9: Operation Introduction

    9 operation introduction before starting operations in this section: 1) find a place where there is power supply nearby. 2) as shown in fig.5 and fig.5a, install the exhaust hose, and adjust the window position well. 3) insert the power cord into an grounded ac115v/60hz socket; 4) as shown in fig. 6...

  • Page 10: Operation Introduction Cont.

    10 operation introduction cont. Maximum cooling minimum cooling maximum heating minimum heating db/wb( 0f ) 95/75 64/54 80/--- 45/--- before using notice: operation temperature range: check up whether the exhaust hose has been mounted properly. Cautions for cooling and dehumidifying operations: ● wh...

  • Page 11: Operation Introduction Cont.

    11 operation introduction cont. ● on time can be regulated at any time in 0-24 hours. Timer off setting ● when the air-conditioner on, press “timer” button and select a desired off time through the temperature and time setting buttons. ● “preset off time” is displayed on the operation panel. ● off t...

  • Page 12: Installation Explanations

    12 3 0 c m 3 0 c m installation explanations installation explanations: ● a removal air-conditioner shall be installed in the flat and empty place all around. Don’t block the air outlet, and the required distance around should be at least 30cm. (see fig.7) ● should not be installed in dry cleaner. ●...

  • Page 13: Installation Explanations

    13 installation explanations window slider kit installation the installation manner of window slider kit is mostly in “horizontal” and “vertical”, no much difference in actual process. As shown fig. 9 and fig. 9a, check the min. And max. Size of the window. Internal tank water full alarm function th...

  • Page 14: Maintenance Explanations

    14 maintenance explanations declaration: 1) before cleaning, be sure to disconnect the unit from any electric supply outlet; 2) do not use gasoline or other chemicals to clean the unit; 3) do not wash the unit directly; 4) if the conditioner is damaged, please contact the dealer or repair shop. Air ...

  • Page 15: Troubleshooting

    15 troubleshooting troubles possible causes suggested remedies 1. Unit does not start when pressing on/off button water full indicator lamp blinks, and water tank is full. Dump the water out of the water tank. Room temperature is higher than the setting temperature. (electric heating mode) reset the...

  • Page 16: Troubleshooting Cont.

    16 troubleshooting cont. Troubles possible causes suggested remedies 3. Auto power- off in heating mode heating protection, when the temperature at the air outlet exceeds 158 f0, the unit will power off automatically. Restart the unit at enough lower room temperature. 4. Noisy the ground is not leve...

  • Page 17: North Storm

    17 repairs must be carried out by authorized specialists to ensure electrical safety. Please contact the service agent or a suitably qualified electrician. Improper repairs could lead to danger. The warranty does not cover damage or failure that results from alteration, accident, misuse, abuse, negl...