NorthRoad Technologies Geyser 6000–3.0 Installation & Owner's Manual - page 5
–5–
GEYSER 6000–3.0™
Overview
The Geyser 6000–3.0 from North Road Technologies is a Heat Pump Water Heater that makes
use of a renewable energy source – the heat in the air in your basement, garage or utility room – to
heat your water. By using this renewable energy source, you significantly reduce the use of electricity,
oil, gas, or propane, which means lower costs, fewer emissions, smaller carbon footprint, and a safer
and healthier environment for you and your family. This is a simple step that anyone can take to help
the environment and reduce our demands on fossil fuels.
The GEYSER 6000–3.0™ Heat Pump Water Heater is an energy-saving appliance that heats water
using heat and moisture from the surrounding air. It uses modern refrigeration technology to
upgrade and transfer this heat to water stored in a standard electric water heater tank. The electric
water heater should have operational thermostats and elements. The tank provides hot water
storage; the GEYSER 6000–3.0 thermostats control the GEYSER 6000–3.0™ operation and the tank
elements are only used for back-up heating/quick recovery.
The GEYSER 6000–3.0™ cycles on when the thermostat calls for water heating. Ambient air cooling
and dehumidification are produced as water is heated. The cooling and dehumidification effects are
dependent on the run time of the GEYSER 6000–3.0™; the more hot water used, the more run time,
the more cooling and dehumidification.
Technical Specifications
Features:
Highly efficient safe and reliable.
Significant energy savings over conventional heating sources.
Fail safe design ensures hot water at all times.
Suitable for nearly any size residential or light commercial water tank.
Engineered for flexible and easy installation.
Virtually maintenance free.
Dehumidifies and cools surrounding air.
5 year limited warranty.
Easy and safe installation, saving time.
Fast recovery and first hour heating.
Vented heat exchanger to meet local and national safety codes.
Unit Specifications:
6,000 BTU/hr (,750 Watts).
Default tank temperature setting is 0° F. (49° C.) in accordance
with U.S. Department of Energy guidelines.
Adjustable from 90-40° F. (3-60° C.). See General Cycle section in this
manual for instructions on changing the default setting.
.5 gal/hr (47.3 Liters) recovery @ 0°F. (49° C.) tank
temperature and at (60°F. (5.5° C.) water supply).
6.5 gallon (36.6 Liter) first hour rating*.
Heats water up to 40°F. (60° C.).
5 Volt/60hz.
5-0 Amp draw (suitable for any 0 volt household outlet).
Dimensions: 6” (40.6 cm) width x 5” (34.6 cm) height x 0” (46. cm) depth.
Durable coated steel outer shell for years of trouble free service.
QPS/SGS Listed (UL-995 / CSA C. No. 36). *Based on 50 Gallon Tank
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•