NOVA ELECTRIC CGL SERIES User Manual - page 4
NOVA
ELECTRIC
A
DIVISION
OF
TECHNOLOGY DYNAMICS, INC.
045670
100 SCHOOL STREET
04/11/2003 Revision -
BERGENFIELD, NJ 07621-2915
CGL 600W INVERTER MANUAL
PHONE 201-385-0500
URL: www.novaelectric.com
FAX 201-385-0702
Page 4
1. Introduction:
This power inverter series are part of the most advanced line of mobile AC power
systems available.
This model is used in a wide range of applications including mobile equipment shelters,
remote homes, RVs, sailboats and powerboats. It will operate most televisions and VCRs
personal computers, small appliances and tools such as drills, sanders, grinders, mixers
and blenders, within the power ratings shown in the table on the prior page.
To get the most out of the power inverter, it must be installed and used properly. Please
read the instructions in this manual before installing and using this model.
1. Name and Main Function:
Front View:
2-1-1. ON / OFF Switch:
Power ON/OFF switch: Leave in the OFF position during installation.
2-1-2. Input Level: Displays Input Voltage
LED Status
DC 12V
DC 24 V
DC 48V
RED Blink (slow)
10.5 ~ 10.9
21.0 ~ 21.8
42.0 ~ 43.6
RED
10.9 ~ 11.3
21.8 ~ 22.6
43.6 ~ 45.2
ORANGE
11.3 ~ 12.0
22.6 ~ 24.0
45.2 ~ 48.0
OFF
12.0 ~ 14.0
24.0 ~ 28.0
48.0 ~ 56.0
ORANGE Blink
14.0 ~ 14.7
28.0 ~ 29.4
56.0 ~ 58.8
OVER RED Blink
14.7 ↑ 29.4
↑ 58.8
↑
Load Level: Displays AC Load Watts
LED Status
Load Condition
OFF
0 ~ 30W
GREEN
30W ~ 200W
ORANGE
200W ~ 450W
RED
450W ~ 580W
RED BLINK
Over 580W
Fault Conditions:
OVP: over voltage protection
UVP: under voltage protection
OVER TEMP: over temperature protection
OVER LOAD: over load protection
INPUT LEVEL: display input voltage