    Lingo ® se baseplate installation instructions description the lingo ® se energy infosystem is the next generation control processor that functions as a system network manager and control monitor in novar’s logic one ® advanced building control system. Lingo se monitors and logs the operations of th...

  • Page 2

    Lingo se without touchscreen operating temperature: 32° to 140°f (0° to 60°c) 0–80% rh, noncondensing storage: –40° to 158°f (–40° to 70°c) 0–90% rh, noncondensing physical dimensions (baseplate only) height: 19.25 inches width: 13.25 inches depth: 2.5 inches weight: 8 lb (all aluminum enclosure) pr...

  • Page 3

    Step procedure 1 remove the baseplate’s cover. § use the hex wrench included with the baseplate to loosen the two screws at the bottom of the baseplate. § lift off the cover. 2 position the baseplate against the wall. 3 mark the wall to show the locations of the four slotted mounting holes in the co...

  • Page 4

    Supplying the lingo se with power the lingo se is powered by a 24-vac, 40 va, class 2 transformer (not included—the transformer kit must be purchased separately). The transformer must be installed not more than 50 feet from the lingo se using minimum 18-gauge wire or mounted directly to the lingo se...

  • Page 5

    Note! The lingo se requires continuous power for proper operation. Make sure the lingo se power cannot be switched off accidentally. Note! The lingo se requires a dedicated transformer for the electronics. A separate transformer must be provided for its control outputs. Wiring the lingo se inputs an...

  • Page 6

    Outdoor humidity sensor step procedure 1 connect the white (+) wire from the sensor to lingo se’s terminal 23 (+) at the humidity sensor input connections. 2 connect the black (–) wire from the sensor to lingo se’s terminal 22 (–) at the humidity sensor input connections. Demand pulse input step pro...

  • Page 7

    Use two-conductor, shielded cable (novar wir-1010, belden 8761, or equivalent) and the following procedure to make the module communications connections. Step procedure 1 connect the black wire from the cable to the negative (–) terminal. 2 connect the shield wire to the shield terminal. 3 connect t...

  • Page 8

    Model and part numbers the part numbers shown in table 1 should be used to order the necessary novar parts. Table 1. Novar part numbers product model no. Part no. Lingo se baseplate lingo/2-bpl 750110000 lingo se electronics assembly (no options) options: lingo se with integral touchscreen lingo se ...