OARTEC DX User Manual - page 21
20
7.
Replace outer cover and
align overlap in mesh.
Tighten bolts making sure the
nut thread correctly onto the bolt
before tightening.
Cleaning the Flywheel and Flywheel Housing
Frequency: After 100 hours of use or every 6- 12 months.
Tools required: 5mm Allen key, 16mm wrench
Dust can build up inside the flywheel housing and on the flywheel blades. While not a major problem, the dust
will accumulate over time and can alter the resistance range, generally making each resistance setting lighter.
Follow the process below to open the flywheel housing and remove the accumulation of dust from the intake,
the exhaust mesh and the flywheel blades.
1.
Using just the 5mm key, loosen the 3 housing bolts.
3.
Release the mesh strip.
WARNING: Careful to not let the mesh spring open
which can cause injury.
5.
Clean flywheel, mesh strip, and the
inner and outer housing of dust. Replace
the flywheel and tighten driveshaft nut.
6.
Insert the mesh strip into
the slot in the inner housing
overlapping the mesh at the
bottom.
4.
Using the 17mm wrench, undo the flywheel
driveshaft nut and remove the flywheel.
2.
Remove the outer flywheel housing, while keeping
the mesh strip in place in the inner housing.