The OASys can be controlled using either the Keys on the Thermostat or the optional Infrared remote
Control:
THERMOSTAT CONTROLS. A beep sound is heard when any key is pressed.
• POwer: Switch the OASys on or off.
• uP: Increases the Set Temperature. Also used to adjust the Timer.
• DOwn: Decreases the Set Temperature. Also used to adjust the Timer.
• MODe: Changes the mode to Fan Only, Manual Cool or Auto Cool.
• FAn: This key changes the Fan speed to High, Medium or low.
• TIMer: This key selects the Timer. Up/Down keys are used to adjust the Timer value.
• SleeP: This key selects or de-selects the Sleep Function.
• PuMP: To switch On/Off the Circulation Pump in Manual Mode.
• DuMP: To Switch On/Off the Dump Pump in Manual Mode.
• PrOGrAM: To Adjust the time for the Purge Cycle- will show S1 (2-12Hrs.)
InDICATOrS
There are two types of Indicators on the OASys, leD Indicators and the Display.
LED INDICATORS
There are 6 leD lights on the Thermostat to indicate the following:
• AuTO COOl: To indicate the Auto Cool mode selection.
• SleeP: To indicate the Sleep mode selection
• TIMer: To indicate the timer selection
• PuMP: To indicate that the water Circulation Pump is On
• FIll: To indicate that the OASys fill valve is working
• POwer: To indicate that 120 volt AC power is reaching the OASys unit
DISPLAY:
• The Display normally shows the Room Temp up to 99 degrees Fahrenheit
• The display changes to Set Temperature for 4 seconds if any signal is received from the Receiver
or from the remote Controller.
• Shows the modes “Fn” (Fan),“CL” (Cool) or “AC” (Auto Cool), if the mode key on receiver
board is pressed.
• Shows the fan Speed “F1” (Low), “F2” (High) , “F3” ( High) or “FA” (Fan Auto) if the fan key on
receiver is pressed.
• Timer value in Hrs (e.g. 01, 02) will be displayed when timer is set by the TIMER key on receiver
board.
• During any operation from the LCD transmitter, Display will show the set Temp as is displayed
on the lCD screen of Transmitter.
• In Standby State Display shows “OF”.
• Display blinks (After 250 Hrs) to indicate that Biocides needs to be replenished