Oasys SEER 40 PLUS Owner's Manual - page 16
OASys Owner’S MAnuAl | www.oasysairconditioner.com | 800-537-2107
15
InSTAllATIOn InSTruCTIOnS
INSTALLATION CHECKLIST
• If you have never installed an OASys before, read this manual from cover-to-cover
• Determine a suitable location for the OASys, observing clearance requirements
• Select air supply and relief locations
• Select thermostat location (not directly in the supply air stream)
• Correctly size all ducting and registers
• Provide for water service, drain, and electrical service
• Obtain all materials required for the installation
• Install the OASys in accordance with this manual and all applicable building codes
• Set controls for correct purge cycle frequency
• Clear pump inlet and inlet screen of any debris
• Verify proper system operation
• Instruct the owner on use of the system and provide them with this manual
SAFETY
The following precautions should be taken to avoid shock hazard when installing or servicing this unit:
• ALWAYS DISCONNECT POwer wHen MAKInG eleCTrICAl COnneCTIOnS Or Ser-
VICInG THe unIT. removal of the control board while the unit is connected to power will
result in permanent damage to the board and exposure to shock hazard.
• In the event of water spillage inside the unit, disconnect power and allow all electrical compo-
nents to dry prior to restoring power.
• Observe wiring and grounding requirements as indicated in these instructions and the electric
code.
PLANNING THE INSTALLATION
SIzING
Two to three ton capacity depending on climate.
Selecting a location for the OASys
The following information will help in selecting a location for the OASys:
• The OASys may be mounted on an outside pad, a roof or bracketed to a wall. The OASys can
be placed in a garage with adequate drainage in case of overflow or leaks. Indoor installation
such as in an attic or utility closet is possible but not recommended. If the unit is not properly
installed leaking can occur which could seriously damage the interior of a home. A drain pan
should always be used in such an installation in case of condensation or other leaks. Interior
installation may nullify certain parts of the warranty and or service agreements.
• The OASys requires a dedicated 115V circuit, cold water supply, and a location to discharge drain
water in accordance with local codes.
• A supply air connection to the house, an outside air intake, and a “secondary” air outlet must be
provided
(see Fig. 1). Secondary air should be discharged to the outside, and may be discharged into an
attic or space
vented to the outside.
• Do not install the unit such that the air intake is 10 feet or less from an appliance vent outlet,