Double click on the camera to activate it in a
Windows browser. The first time that this
camera is used will display the Configure
Root Password.
T
HE SYSTEM HAS BEEN RECONFIGURED TO
ACCEPT THE ROOT PASSWORD OF
“
ADMIN
.”
To set the password for the root
(administrator) user:
1. Enter a password and then re-enter it to
confirm the spelling. Click OK.
2. The ‘Enter Network Password’ dialog will
appear. Enter the User name: root.
3. Enter the password as set above, and
click OK. If the password is lost, the
cameras must be reset to the factory
default settings.
1.2 D
EPLOYMENT
T
ESTING
The camera can be deployed while the
network is operational. This will allow the
monitoring of any leakage.
DO NOT PLUG IN OR REMOVE THE
HOUSING P
O
E CONNECTOR WHILE
UNDERWATER WHEN THE POWER
IS ON!
The camera is slightly negatively buoyant.
Weights can be added to decrease the
buoyancy. Attach weights to each side of
the housing using the metal bar and plastic
cable ties.
It is advisable to test the system in fresh
water prior to saltwater deployment. If this is
not possible, lower the camera into the
water with the camera pointing vertical and
the network active.
If a perfect o-ring seal has not been
obtained, fogging or condensation will soon
appear on the inside.
A submergence test can also we performed
without power applied. Lower the system to
a depth of 10 feet and then remove it for
visible inspection for leaks. If possible, test
the system again at a depth of 30 feet for 15
minutes.
IF ANY MOISTURE IS SEEN ON THE
TOP OF THE PORT, REMOVE THE
SYSTEM FROM THE WATER
IMMEDIATELY!
If moisture is seen on the top inside of the
port, either the O-ring was not properly
sealed or additional moisture removal may
be required. If a dry system cannot be
obtained, please contact the manufacturer
for assistance.