Ocular RobotEye RE01 Imaging User Manual - page 11
Basics
8
www.ocularrobotics.com
Ocular Robotics Pty Ltd
3. Make sure the 24 volt power supply is switched OFF. Connect the supplied power
cable to the 24 volt power supply. On the unterminated end of the cable you will find
two wires one black and one with a red sheath on it. The black wire should be
connected to the negative terminal on the power supply. The cable with the red
sheath should be connected to the positive terminal on the power supply. The green
and yellow cable should be connected to a ground reference.
WARNING - Make sure the power supply is not powered before
connecting the cables.
4. Connect the power supply cable to the corresponding plug on the RE05 system.
Ensure the correct orientation by aligning the polarisation keys on the panel
connector and the plug. If forced in the incorrect orientation, damage to the system
is likely to result. Refer to Section 3.2.2 - Power for further details.
5. If your RE01 Imaging System was ordered complete with an Allied Vision
Technologies camera then your system should be ready to use. For adjusting the
Focus and Aperture of your camera see Section 3.5.3 - Camera Focus and Aperture.
Otherwise follow steps a) to i) to install your chosen camera.
a) Open the system enclosure by removing the eight countersunk socket screws
from the base.
b) Connect the chosen GigE camera to the C-mount thread on the end of the RE01
unit. A universal camera mount to suit all Allied Vision Technologies cameras
recommended for use with the RE01 Imaging product is supplied with the RE01
Imaging System. If a different camera is chosen and it can’t be used with the
mount provided then alternative mounting arrangements should be provided.
DO NOT allow the camera to be unsupported on the camera lens.
c) The camera lens should be rotated on the filter thread where it attaches to the
RE01 by the minimum amount required to align the body of the camera to one of
the two possible camera mount positions shown in Figure 3.12.
d) Remove two socket head screws in the base of the RE01 body in the chosen
position for the attachment of the camera mount (DO NOT have any more than
two screws removed from the base of the RE01 at any time). Place the camera
mount in position and replace the socket screws but do not tighten until the
mount is attached to the camera.