OHAUS Valor 7000 series Instruction Manual

Other manuals for Valor 7000 series: Service Manual

Summary of Valor 7000 series

  • Page 1

    Val or™ 7000 series instruction manual.

  • Page 3: Valor™ 7000

    Valor™ 7000 series en-1 1. Introduction this manual contains installation, operation and maintenance instructions for the valor ™ 7000 series. Please read the manual completely before using the scale. 1.1 definition of signal warnings and symbols safety notes are marked with signal words and warning...

  • Page 4: En-2

    En-2 valor™ 7000 series 2.2 installing components install the sub-platform and metal pan as shown below. Press to lock the sub-platform into place. Figure 2-1. Install the sub-platform and metal pan 2.3 selecting the location use the scale on a firm, steady surface. Avoid locations with excessive ai...

  • Page 5: Valor™ 7000

    Valor™ 7000 series en-3 2.5 connecting power ac power is used to power the scale when battery power is not needed. First, connect the ac power cord (supplied) to the power input jack then connect the ac plug to an electrical outlet. Figure 2-3a connect the ac power plug to the input jack on the back...

  • Page 6: En-4

    En-4 valor™ 7000 series 3. Operation 3.1 controls figure 3-1. Valor 7000 front control panel with lcd display. Table 3-1 button functions on/zero off 3 yes short press 1 (when on): sets display to zero (when off): turns scale on long press 2 (when on): turns the scale off short press (in menu): sele...

  • Page 7: Valor™ 7000

    Valor™ 7000 series en-5 ir sensor (back) table 3-2 item description item description 1 net symbol 9 calibration / menu mode symbol 2 center of zero symbol 10 dynamic symbol (not used) 3 negative symbol 11 battery charge symbol 4 stable weight symbol 12 pound, ounce, pound:ounce symbols 5 preset tare...

  • Page 8: En-6

    En-6 valor™ 7000 series figure 3-4. Below view of valor 7000 ir sensors the valor 7000 is equipped with two ir sensors, one at the front (see figure 3-5) and one at the rear (see figure 3-3). The front and rear sensors perform the same function. The sensors can be activated by a hand or other object...

  • Page 9: Valor™ 7000

    Valor™ 7000 series en-7 3.2 turning scale on/off to turn the scale on, press and hold the on/zero off button for 1 second. The scale performs a display test, momentarily displays the software version, and then enters the active weighing mode. To turn the scale off, press and hold the on/zero off but...

  • Page 10: En-8

    En-8 valor™ 7000 series 3.5 check mode use this mode to compare the weight or percent of items to a target range. The scale supports positive, negative and zero check weighing. Refer to section 4.5 to set the desired check sub-mode. 3.5.1 check weighing set checkweigh to weight in the mode menu. Use...

  • Page 11: Valor™ 7000

    Valor™ 7000 series en-9 9. If required, place an empty container on the pan and press tare. 10. Place sample material on the pan or in the container. If the sample weight is under the target percentage range, the yellow led will light. If the sample is within the target percentage range, the green l...

  • Page 12: En-10

    En-10 valor™ 7000 series 3.6 accumulation and statistics the accumulation feature enables manual or automatic totalizing of displayed values. Statistical data (total accumulated, min and max weight or %, and total number of weighments) is stored in memory for review and printing. Accumulation works ...

  • Page 13: Valor™ 7000

    Valor™ 7000 series en-11 4. Menu settings the user menu allows the customizing of scale settings. Note: additional sub-menus may be available if interface options are installed. See interface user manual for the additional setting information. 4.1 menu navigation user menu: menu: c.A.L s.E.T.U.P r.E...

  • Page 14: En-12

    En-12 valor™ 7000 series summary of button navigation functions in menu mode: -- yes allows entry into the displayed menu. - accepts the displayed setting and advances to the next item. -- no skips by the displayed menu. - rejects the displayed setting or menu item and advances to the next available...

  • Page 15: Valor™ 7000

    Valor™ 7000 series en-13 4.2 cal menu enter this menu to perform calibrations. Initial calibration when the scale is operated for the first time, a span calibration is recommended to ensure accurate weighing results. Before performing the calibration, be sure to have the appropriate calibration weig...

  • Page 16: En-14

    En-14 valor™ 7000 series 4.3 setup menu enter this menu to set scale parameters. Default settings are bold. Reset [reset] reset the setup menu to factory defaults. No = not reset yes = reset power on unit [pwwr.Un] set the unit of measure displayed at startup. Auto = last unit in use when turned off...

  • Page 17: Valor™ 7000

    Valor™ 7000 series en-15 ir func [ir.F] define the sensor function. Both sensors will have the same function. Disp = turn on backlight zero = scale performs zero operation func = scale performs function operation tare = scale performs tare operation print = scale performs print operation ir adjust [...

  • Page 18: En-16

    En-16 valor™ 7000 series 4.4 readout menu enter this menu to set user preferences. Default settings are bold. Reset [reset] reset the read menu to factory defaults. No = not reset yes = reset stable range [stable] set the amount the reading can vary while the stability symbol remains on. 0.5d = 0.5 ...

  • Page 19: Valor™ 7000

    Valor™ 7000 series en-17 end readout [end] advance to the next menu or return to the top of the current menu. 4.5 mode menu this sub-menu activates modes so they will be available for use with the mode button. Weigh mode is always active. Default settings are bold. Reset [reset] reset the mode menu ...

  • Page 20: En-18

    En-18 valor™ 7000 series 4.7 print1 menu enter this menu to set printing parameters. Default settings are bold. Note: the print2 menu is only displayed if a second interface is installed. Reset [reset] reset the print menu to factory defaults. No = no reset yes = reset stable only [stable] set the p...

  • Page 21: Valor™ 7000

    Valor™ 7000 series en-19 content [contnt] define the content of the printed data. See section 7.4 for sample printouts. Result set the status. Off = disabled on = the displayed reading is printed gross set the status. Off = disabled on = the gross weight is printed net set the status. Off = disabled...

  • Page 22: En-20

    En-20 valor™ 7000 series layout [layout] set the format of the data output to a printer or computer. Format set the printing format. Multi = a multi-line (single column style) printout is generated. Single = a single line printout is generated. Feed set the paper feed. Line = move a paper up one lin...

  • Page 23: Valor™ 7000

    Valor™ 7000 series en-21 4.8 com1 menu enter this menu to define communication parameters. Default settings are bold. Note: the com2 menu is only displayed if a second interface is installed. Reset [reset] reset the com menu to factory defaults. No = no reset yes = reset baud rate [baud] set the bau...

  • Page 24: En-22

    En-22 valor™ 7000 series alternate command [alt.Cmm] define command character for the print, tare and zero commands print set the alternate command character for print a to z. Tare set the alternate command character for tare a to z. Zero set the alternate command character for zero. A to z. End com...

  • Page 25: Valor™ 7000

    Valor™ 7000 series en-23 lock mode [l.Mmod] set the status. Off = mode menu is not locked on = mode menu is locked lock unit [l.Unit] set the status. Off = unit menu is not locked on = unit menu is locked lock print [l.Print] set the status. Off = print menu is not locked on = print menu is locked l...

  • Page 26: En-24

    En-24 valor™ 7000 series 4.11 additional features to use this feature, remove ac power from the scale and remove the protective cover for the weigh below opening. Install a suitable hook into the access hole at the bottom of the scale as shown (refer to section 6.4 for optional hook). Do not over ti...

  • Page 27: Valor™ 7000

    Valor™ 7000 series en-25 table 4-2. Geo codes 0 325 650 975 1300 1625 1950 2275 2600 2925 3250 325 650 975 1300 1625 1950 2275 2600 2925 3250 3575 0 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 11730 0°00' 5°46' 5 4 4 3 3 2 2 1 1 0 0 5°46' 9°5...

  • Page 28: En-26

    En-26 valor™ 7000 series 5. Legal for trade when the scale is used in trade or a legally controlled application it must be set up, verified and sealed in accordance with local weights and measures regulations. It is the responsibility of the purchaser to ensure that all pertinent legal requirements ...

  • Page 29: Valor™ 7000

    Valor™ 7000 series en-27 figure 5-1. Sealing 5.3.2 audit trail seal (usa and canada only) for jurisdictions that use the audit trail sealing method, the local weights and measures official or authorized service agent must record the current configuration and calibration event counter values at the t...

  • Page 30: En-28

    En-28 valor™ 7000 series 6. Maintenance 6.1 cleaning the housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean the housing or control panel. 6.2 troubleshooting table 6-1 lists common problems and possi...

  • Page 31: Valor™ 7000

    Valor™ 7000 series en-29 6.3 service information if the troubleshooting section does not resolve or describe your problem, contact your authorized ohaus service agent. For service assistance or technical support in the united states call toll-free 1-800-526-0659 between 8:00 am and 5:00 pm est. An o...

  • Page 32: En-30

    En-30 valor™ 7000 series 7. Technical data the technical data is valid under the following ambient conditions: indoor use only operating temperature: -10°c to 40°c relative humidity: 20% to 85% relative humidity, non-condensing altitude: up to 2000 m power: ac power 100-240v 50/60 hz, internal recha...

  • Page 33: Valor™ 7000

    Valor™ 7000 series en-31 7.2 drawings figure 7-1. Dimensions 311 mm / 12.2 in 327 mm / 12.9 in 117 mm / 4.6 in.

  • Page 34: En-32

    En-32 valor™ 7000 series 7.3 communication the scale is equipped with an rs232 interface (com1) located under the options cover. Connecting the scale to a computer enables you to operate the scale from the computer, as well as receive data such as displayed weight. 7.3.1 interface commands communica...

  • Page 35: Valor™ 7000

    Valor™ 7000 series en-33 7.4 printouts the following sample print outs are generated by the print button, “p” command or alternate print command. The content of the printout is defined in the print content menu item. A maximum of 24 characters can be printed on each line. Weigh mode printout descrip...

  • Page 36: En-34

    En-34 valor™ 7000 series stability - “?” character is printed if not stable. If weight is stable neither “?” or following space is printed. G/n - “net” printed if weight is net weight, ‘g’ or nothing printed if weight is a gross weight. Terminating character(s) - terminating character(s) printed dep...

  • Page 37: Valor™ 7000

    Valor™ 7000 series en-35 disposal in conformance with the european directive 2002/96/ec on waste electrical and electronic equipment (weee) this device may not be disposed of in domestic waste. This also applies to countries outside the eu, per their specific requirements. The batteries directive 20...

  • Page 38: En-36

    En-36 valor™ 7000 series limited warranty ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period ohaus will repair, or, at its option, replace any component(s) that proves to be defec...

  • Page 40

    Ohaus corporation 7 campus drive suite 310 parsippany, nj 07054 usa tel: +1 973 377 9000 fax: +1 973 944 7177 with offices worldwide / con oficinas alrededor del mundo / avec des bureaux dans le monde entier / weltweite geshäftsstellen / con uffici in tutto il mondo. Www.Ohaus.Com *30048239* p/n 300...