Oilon Geopro RE Operation Manual - page 10
RE010070948EN
10/23
3.3.4.
Changing room temperature settings
Desired room temperature can be changed by turning adjusting wheel at standard mode..
When turning adjusting wheel flashing setting appears on display, and it can be raised or
lowered using adjusting wheel. Accept change by pressing OK –button, and rejected with
Return –button.
3.3.5. Changing
heating
circuit operating mode
Heating circuit operating mode can be changed with button located at panel upper right corner.
Heating circuit operating modes are following:
Cooling (activated with cooling button)
Automatic (According to time program)
Comfort setpoint
Reduced setpoint
Frost protection
If selected operating mode is automatic, set corresponding time program with desired time
periods. Set time periods at “Time program heating circuit 1 (2)” menu. First select dates, when
time periods are set. Then set time periods for comfort use. Other time periods Operating mode
is Reduced setpoint.
3.3.6.
Changing heating curve
Change heating curve from corresponding heating circuit menu (Heating circuit 1 or Heating
circuit 2). Set heating curve slope at lines 720 (1) and 1020 (2). Heating curves for 20 degree
indoor temperature demand are marked in the drawing.
20
10
0
-10
-20
-30
90
80
70
60
50
40
30
°C
°C
4
3,5
3
2,75
2,5
2,25
2
1,75
1,5
1,25
1
0,75
0,5
0,25
100
20
0
0
D
0
2
For floor heating circuits heat curve setting is approx. 0,5, and for radiator heating circuits max.
1,25. Heat pump pre-setting is 0,8.