OJ Electronics UCCG-9991 User Manual - page 4
Press the pin button for 3 secs. and the thermostat returns to factory settings. Time,
day and scale for time (12h, 24h) and temperature (˚F, ˚C) read-out are also reset and
must be set according to “Setting the thermostat into operation”.
5. Reset to factory setting
4-event time and temperature
Day 1-5
06:00
Time
With floor sensor
Built-in sensor
08:00
16:00
22:30
08:00
23:00
5:2
4-event sequence
131˚F / 41˚F
24 H / ˚F
ON
Hi-Low temp.
Scale
Adaptive control
Day 6-7
77˚F / 25˚C
68˚F / 20˚C
68˚F / 20˚C
59˚F / 15˚C
81˚F / 27˚C
72˚F / 22˚C
68˚F / 20˚C
59˚F / 15˚C
81˚F / 27˚C
72˚F / 22˚C
68˚F / 20˚C
59˚F / 15˚C
6. Failure codes
E0 =
Internal failure, replace thermostat
E1 =
Built-in sensor short-circuit or disconnected,
replace thermostat
E2 =
External sensor short-circuit or disconnected
7. Technical data
Supply: . . . . . . . . . . . . . . . . . . 120/240 Vac 50/60 Hz
Load:
. . . . . . . . . . . . 16A maximum (resistive load)
Power: . . . . . . . . . . . . . . . . . . . . 1.920 W at 120 Vac
3.840 W at 240 Vac
GFCI:
. . . . . . . . . . . . . . . . . Class A (5 mA trip level)
Temperature range: . . . . +5 to +40°C, +40 to +104˚F
Amb. Temperature range:
Thermostat: . . . . . . . . . . . 0 to +40°C, +32 to +104˚F
GFCI:
. . . . . . . . . . . . . -35 to +65°C, -31 to +149˚F
OJ ELECTRONICS A/S
Stenager 13B · DK-6400 Sønderborg
Tel. +45 73 12 13 14 · Fax +45 73 12 13 13
www.oj.dk
Factory settings