Type uccg, ucdg u s e r m a n u a l product program this user manual covers following thermostats with built-in gfci uccg-9991 incl. Floor sensor 3m uccg-9999 with built-in room sensor ucdg-9999 with 2 sensors; built-in room sensor and incl. Floor sensor 3m introduction the thermostat is an electron...
Checking gfci it is important that the gfci has been checked for correct installation and function. To check the gfci: testing can only be performed if the thermostat has a heating demand. Adjust the set point until the heating symbol (sss) appears, use the ( ), to increase the heating demand. Wait ...
Monitoring of energy consumption. The thermostat calculates average time it has been switched on allowing you to monitor your energy consumption. In the thermostat you can read out:. Total switch-on time in percentage in the latest 2 days, 30 days or 365 days. Calculation of operational costs per da...
Press the pin button for 3 secs. And the thermostat returns to factory settings. Time, day and scale for time (12h, 24h) and temperature (˚f, ˚c) read-out are also reset and must be set according to “setting the thermostat into operation”. 5. Reset to factory setting 4-event time and temperature day...
Type utcg, uccg, ucdg i n s t r u c t i o n s lagernummer: 57609 - 08/03 (bj) english the thermostat is an electronic on/off thermostat for control of temperature by means of an ntc sensor either placed externally or internally in the thermostat. The thermostat has integrated a ground fault circuit ...
Br928a06 fig. 1 br928a02 fig. 3 br928a07 sensor temp.(˚c) value (ohm) -10 0 10 20 30 64000 38000 23300 14800 9700 temp.(˚f) 68 86 50 32 -14 fig. 5 1/4" 1/4" strip length br928a05 l1 l2 120/240vac 16a 1920w / sensor 3840w fig. 2 1,6m fig.4.