Oki BV1250 Technical Reference
Summary of BV1250
Page 1
Bv1250 internet voice gateway t echnical r eference oki electric industry co., ltd..
Page 3
Bv1250 technical reference rev. 1.0 page i ! Safety warning! This document contains information relating to the safe installation, maintenance, and use of the oki bv1250. Carefully note all safety precautions and procedures contained in this document before installing and using the product..
Page 4
Bv1250 technical reference page ii rev. 1.0 the bv1250 internet voice gateway and the maintenance console software are products of oki electric industry co. Ltd. Right to reproduce this manual and/or the maintenance console software is restricted by the copyright act. No part of this document may be...
Page 5
Bv1250 technical reference rev. 1.0 page iii limited warranty oki electric industry co., ltd. Warrants that these products (bv1250 and maintenance console software) are free of manufacturing defects during the warranty period and while operating under normal conditions. In the event of failure, a re...
Page 6
Bv1250 technical reference page iv rev. 1.0
Page 7
Bv1250 technical reference rev. 1.0 page v table of contents bv1250 description bv1250 description bv1250 description bv1250 description ................................ ................................ ................................ ...................................................................
Page 8
Bv1250 technical reference page vi rev. 1.0 on-line command reference on-line command reference on-line command reference on-line command reference ................................ ................................ ................................ ........................................................
Page 9
Bv1250 technical reference description rev. 1.0 page 1 bv1250 description the oki bv1250 internet voice gateway (ivg) is a self-contained device that allows organizations to route both voice and fax communications over any ip compatible network. Oki’s ivg seamlessly bridges existing pbx, key telepho...
Page 10
Description bv1250 technical reference page 2 rev. 1.0
Page 11: 1. Specifications
Bv1250 technical reference description rev. 1.0 page 3 1. Specifications bv1250 internet voice gateway (us = united states ver., jpn = japan ver., eu = european ver.) general: operational unit consists of a base unit, an e&m/e&m-od, fxs, fxo, or bri line interface board. Physical: dimensions w = 420...
Page 12
Description bv1250 technical reference page 4 rev. 1.0 line and fax interfaces: a functional bv1250 unit must have a line interface card installed. The interface may be fxs (analog), fxo (analog), e&m (types 1 and 2), or e&m–od (type 5). The g3 facsimile interface is available with all of the above....
Page 13: 2. Bv1250 External Views
Bv1250 technical reference description rev. 1.0 page 5 2. Bv1250 external views the external characteristics of a bv1250 unit are shown below. 2.1 base unit configuration figure 2-1 illustrates the basic configuration of all versions bv1250 units. The only difference between unit configurations is t...
Page 14
Description bv1250 technical reference page 6 rev. 1.0 bv1250 external features the bv1250 base unit front and rear panels have various physical elements associated with supplying power to the unit and providing operational status information. Figure 2-2 illustrates these features. These features ar...
Page 15
Bv1250 technical reference description rev. 1.0 page 7 table 2-1: description of bv1250 external feature item description 1 power lamp indicates power on when lamp lit green lamp 2 busy lamp when port is in use, lit lamp indicates line is busy orange lamp 3 alarm lamp indicates alarmed condition det...
Page 16: 3. Bv1250 Parts
Description bv1250 technical reference page 8 rev. 1.0 3. Bv1250 parts below is a listing of bv1250 parts along with the part and product numbers. Product name oki networks part number oki-j product no. Basic parts bv1250 base unit 100101 4ya1158-1121g002 bv1250 accessories bv1250 accessories, europ...
Page 17
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 1 bv1250 maintenance and troubleshooting the bv1250 unit is a low maintenance electronic device that, once installed and properly configured, should need only infrequent attention. Other than an occasional external cleaning, al...
Page 18
Maintenance and troubleshooting bv1250 technical reference page 2 rev. 1.0
Page 19: 1. Routine Maintenance
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 3 1. Routine maintenance routine maintenance involves tasks to be performed on a regular basis even when the unit gives no evidence of problems or malfunction. These activities are generally preventative in nature. 1.1 external...
Page 20
Maintenance and troubleshooting bv1250 technical reference page 4 rev. 1.0 1.2 periodic inspection periodic inspection activities should be organized using a maintenance schedule that specifies regular inspection intervals. Inspection need not occur frequently but is best when conducted on a routine...
Page 21
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 5 1.3 file management on occasion it may be necessary to update or restore a bv1250 unit’s system files. The updating or restoration of unit’s system files is performed using the maintenance console software or with the on-line...
Page 22
Maintenance and troubleshooting bv1250 technical reference page 6 rev. 1.0
Page 23: Action
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 7 2. Trouble diagnosis and corrective action when a bv1250 unit problem is detected/reported, a systematic methodology will assist in the diagnosis and correction of the problem. The recommended procedure involves the following...
Page 24
Maintenance and troubleshooting bv1250 technical reference page 8 rev. 1.0 2.1 fault processing on occasion, a fault condition may arise which causes a unit to behave erratically or fail altogether. Should this occur, it is important to take timely action to obtain a trouble report, diagnose, and re...
Page 25
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 9 2.2 guide to trouble indications table 2-1 provides a general troubleshooting guide. In many cases this information will be sufficient to diagnose and correct a problem. If an error not mentioned in the table has occurred, ch...
Page 26
Maintenance and troubleshooting bv1250 technical reference page 10 rev. 1.0 2.3 fault log codes and corrective action the bv1250 maintains a fault log in which fault conditions are recorded as they occur. The fault log is useful in diagnosing problems with a unit and in determining appropriate corre...
Page 27
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 11 table 2-2: fault conditions code code detail equipment message type fault abbreviation seq fault explanation alarm lamp comments and corrective action on event on restore 00 00 system report poweron 00 power on off -- no tro...
Page 28
Maintenance and troubleshooting bv1250 technical reference page 12 rev. 1.0 code code detail equipment message type fault abbreviation seq fault explanation alarm lamp comments and corrective action on event on restore 00 17 fault 00 no dsp program-2 on -- contact customer service 18 fault 00 on -- ...
Page 29
Bv1250 technical reference maintenance and troubleshooting rev. 1.0 page 13 code code detail equipment message type fault abbreviation seq fault explanation alarm lamp comments and corrective action on event on restore 15 01 02 20 02 voice report rfifo_ovf 00-03 receive fifo disconnected status hold...
Page 30
Maintenance and troubleshooting bv1250 technical reference page 14 revision 1.0 3. Trap information sent to nms a trap is one of the signals included in the simple network management protocol (snmp). In the case of the bv1250, a trap signal is sent to a network management system (nms) when a fault i...
Page 31
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 15 specific-trap number: see the list and descriptions of traps in table 3-2 below. Time-stamp value: the time-stamp value corresponds to the system setting for sysuptime of the internet standard mib (mib2). This means that...
Page 32
Maintenance and troubleshooting bv1250 technical reference page 16 revision 1.0 event display equipment name details fault trap? Fault code (specific trap) recovery trap? Recovery code (specific trap) comments and corrective action lanc lanc fault no -- no -- see table 2.2, code 02-00 uplink fault n...
Page 33: 4. Fax Issues
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 17 4. Fax issues in most circumstances, bv1250 fax communications are effective and error free. In some cases though, fax communications may be interrupted when there are high network loads. This condition occurs because th...
Page 34: 5. Fuse Replacement
Maintenance and troubleshooting bv1250 technical reference page 18 revision 1.0 5. Fuse replacement the bv1250 unit has one fuse which is located in the rear panel of the base unit. The fuse protects the unit against over-voltages and power spikes. If the unit’s fuse should burn out, it must be repl...
Page 35
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 19 6. Replacing the bv1250 fan the bv1250 unit fan provides cooling to the components contained in the base unit. If the fan should fail, the unit should immediately be turned off to prevent excessive heat build-up. The uni...
Page 36
Maintenance and troubleshooting bv1250 technical reference page 20 revision 1.0 3. Slide the chassis cover back from the chassis until clear of the locking tab. 4. Lift chassis cover clear of chassis. 5. Store chassis cover in a safe location. 6. Remove the cable that interconnects main board and fa...
Page 37
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 21 7. Common problems and solutions in this section some common problem conditions are described along with appropriate corrective action. Each item begins with a statement of symptoms and is followed by an explanation of t...
Page 38
Maintenance and troubleshooting bv1250 technical reference page 22 revision 1.0 no dial tone, busy lamp off (e&m/e&m-od) symptom: no dial tone is heard when grabbing the e&m trunk form the pbx. The unit’s busy lamp is off. Cause: the unit’s termdld and pbx trunk parameters are incorrectly configured...
Page 39
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 23 when calling, a fast busy tone is returned (fxs, fxo and e&m/e&m-od) symptom: when calling a terminal connected through and e&m, fxs, or fxo unit, a fast busy tone is returned and connection cannot be made. Cause: the ca...
Page 40
Maintenance and troubleshooting bv1250 technical reference page 24 revision 1.0 connection with a remote unit works some times and not at other times (e&m/e&m-od) symptom: sometimes a connection to the remote e&m unit can be made but at other times the connection cannot be established. This is the c...
Page 41
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 25 called pbx returns a busy tone 1 (e&m/e&m-od) symptom: call to e&m unit from a another unit cannot be connected. A busy tone is returned. Cause: called unit’s delete digits parameter incorrectly configured. The delete di...
Page 42
Maintenance and troubleshooting bv1250 technical reference page 26 revision 1.0 network connection not working when using telnet & file transfer protocol (fxs, fxo and e&m/e&m-od) symptom: cannot communicate with unit through a telnet/ftp connection. Cause: the power to the unit is not turned on. Al...
Page 43
Bv1250 technical reference maintenance and troubleshooting revision 1.0 page 27 calls and fax communications for units communicating with the network through a firewall are erratic or cannot be setup (fxs, fxo, and e&m/e&m-od) symptom: cabling and network connectivity have been checked for proper op...
Page 44
Maintenance and troubleshooting bv1250 technical reference page 28 revision 1.0 voice volume too low or voice is distorted and has echo (fxs, fxo, and e&m/e&m-od) symptom: when using the telephone set, the vice volume is too low or the voice sounds distorted and has echo. Cause: the gain setting par...
Page 45
Bv1250 technical reference on-line commands revision 1.0 page 1 on-line command reference the on-line commands described in this reference allow remote control of the bv1250 through a simple text line interface. For experienced users, this interface can be used to quickly configure and manage bv1250...
Page 46
On-line commands bv1250 technical reference page 2 revision 1.0
Page 47
Bv1250 technical reference on-line commands - overview revision 1.0 page 3 1. Command reference overview when using a telnet or lan connection, these commands can be entered using a simple vt100 compatible terminal or terminal window (e.G. The terminal mode window in the maintenance console software...
Page 48
On-line commands - overview bv1250 technical reference page 4 revision 1.0 1.1 command descriptions the command descriptions provided in section 5 of this document are organized in the following manner. Title: includes the command item identifier number and command(s) to be described. Class: the cla...
Page 49
Bv1250 technical reference on-line commands - overview revision 1.0 page 5 1.3 command examples command inputs, prompts, and return messages are displayed throughout this document in a fixed courier font. All command examples are presented in a format that emulates the way in which the data entry an...
Page 50
On-line commands - overview bv1250 technical reference page 6 revision 1.0 abnormal in the following example, the message output indicates that the system could not execute the command and that a problem exists with the command syntax or the equipment itself. Example: xxxxxxxx command error(nnn-nn) ...
Page 51: 2. Utility Commands
Bv1250 technical reference on-line commands – utility commands revision 1.0 page 7 2. Utility commands the utility commands (psh) used in the maintenance of the bv1250 ivg are listed in alphabetical order in table 2-1 . In addition, the access authorization level required to use these commands is in...
Page 52
On-line commands – overview bv1250 technical reference page 8 revision 1.0 item command name summary access (u=user, m=maintenance) 30 resume resume command -- 31 rm delete file command -- 32 rmdir delete directory command -- 33 route command to manually operate a routing table -- 34 setid command t...
Page 53: Maintenance Commands
Bv1250 technical reference on-line commands – command list revision 1.0 page 9 3. Common error numbers for maintenance commands table 3.1 shows a list of common error numbers for maintenance commands. Table 3-1: common error numbers error no. Error name error details 0013 parameter number error too ...
Page 54
On-line commands – command list bv1250 technical reference page 10 revision 1.0
Page 55: 4. Command Summaries
Bv1250 technical reference on-line commands – command list revision 1.0 page 11 4. Command summaries bv1250 on-line commands grouped by type are summarized in table 4.1. Table 4-1: command summaries equipment commands (1-1 to 1-19) no. Name function argument format parameters 1-1 area tone source se...
Page 56
On-line commands – command list bv1250 technical reference page 12 revision 1.0 table 4-1: command summaries (continued) no. Name function argument format parameters 1-13 rx-buffer bv1250 recovery buffer configuration set set-rx-buffer p1= max. Buffer size p2 = start recovery parameter p3 = end reco...
Page 57
Bv1250 technical reference on-line commands – command list revision 1.0 page 13 table 4-1: command summaries (continued) numbering plan commands (3-1 to 3-14) no. Name function argument format parameters 3-1 acposi voice/fax code position set set-acposi p1=dial location get get-acposi none 3-2 dayni...
Page 58
On-line commands – command list bv1250 technical reference page 14 revision 1.0 table 4-1: command summaries (continued) no. Name function argument format parameters 3-10 res-no restriction code set set-res-no p1=restricted digits (fxo only) get get-res-no none reset rst-res-no p1=restricted digits ...
Page 59
Bv1250 technical reference on-line commands – command list revision 1.0 page 15 table 4-1: command summaries (continued) no. Name function argument format parameters 4-5 dld (em only) download value of individual trunk line set set-dld p1=port number p2=dial delay p3=wink-start width p4=speed record...
Page 60
On-line commands – command list bv1250 technical reference page 16 revision 1.0 table 4-1: command summaries (continued) maintenance commands (7-1 to 7-6) no. Name function argument format parameters 7-1 dty set system day and time set dty p1=year (yyyy) p2=month/day (mmdd) p3=hour/minute (hhmm) 7-2...
Page 61
Bv1250 technical reference on-line commands – command list revision 1.0 page 17 the bv1250 ivg on-line commands are listed alphabetically in the following table. Table 4-2: command list command function arguments no. Type acposi voice/fax code position set, get 3-1 numbering plan command agc bv1250 ...
Page 62
On-line commands – command list bv1250 technical reference page 18 revision 1.0 law-flag a-law/m-law setting set, get 4-7 line information command logout mcs logout set 2-3 maintenance console command lst-mod display mode set, get 2-4 maintenance console command mac-adr bv1250 mac address get 1-12 e...
Page 63: 5. Command Descriptions
Bv1250 technical reference on-line commands - command descriptions revision 1.0 page 19 5. Command descriptions the command groups described in this section are: 5.1 equipment commands 5.2 maintenance console commands 5.3 numbering plan commands 5.4 line information commands 5.5 management commands ...
Page 64
On-line commands - command descriptions bv1250 technical reference page 20 revision 1.0
Page 65
Bv1250 technical reference on-line commands - equipment revision 1.0 page 21 5.1 equipment commands equipment commands are used to configure a bv1250 unit’s office data file (ofdd.Vho). All parameters entered are displayed as sby until they are backed-up in the unit using the oup command and the uni...
Page 66
On-line commands - equipment bv1250 technical reference page 22 revision 1.0
Page 67
Bv1250 technical reference on-line commands - equipment revision 1.0 page 23 item 1-1: area (set and get) class equipment command function commands to set and get tone source class (zone) setting characteristics set-area writes a tone class (zone) setting to a bv1250 unit and displays current and ne...
Page 68
On-line commands - equipment bv1250 technical reference page 24 revision 1.0 example(s) set-area nn #set-area us act zone=jp sby zone=us 1 act_tone_dt=1 sby_tone_dt=8 2 act_tone_rbt=2 sby_tone_rbt=2 3 act_tone_bt=3 sby_tone_rbt=3 4 act_tone_dsc=3 sby_tone_dsc=3 5 act_tone_sdt=4 sby_tone_sdt=4 6 act_...
Page 69
Bv1250 technical reference on-line commands - equipment revision 1.0 page 25 item 1-2: audio -cap (set, get, and rst) class equipment command function command to set, get, and reset the audio capabilities used in unit voice transmission. Characteristics set-audio-cap input parameter(s): p1 - input f...
Page 70
On-line commands - equipment bv1250 technical reference page 26 revision 1.0 example(s) set-audio-cap n n #set-audio-cap 3 1 act audio capability=1 2 sby audio capability=3 1 ...Set-audio-cap command end. [thu jan 30 17:54:23 1999] # get-audio-cap #get-audio-cap act audio capability=1 2 sby audio ca...
Page 71
Bv1250 technical reference on-line commands - equipment revision 1.0 page 27 item 1-3: dns-ip (set, get, and rst) class equipment command function commands used to set, get, and reset the dns ip address(s) of bv1250 characteristics set-dns-ip writes from 1 to 3 dns ip address to a bv1250 unit and di...
Page 72
On-line commands - equipment bv1250 technical reference page 28 revision 1.0 example(s) set-dns-ip nnn.Nnn.Nnn.Nnn #set-dns-ip 133.149.216.103 133.149.216.104 133.149.216.105 act external dns_ip_1=133.149.216.203 sby external dns_ip_1=133.149.216.103 act external dns_ip_2=133.149.216.204 sby externa...
Page 73
Bv1250 technical reference on-line commands - equipment revision 1.0 page 29 item 1-4: dns-sernum (set and get) class equipment command function commands to set and get the dns search start digits number characteristics set-dns-sernum writes a value (1 to 32) representing the number of digits requir...
Page 74
On-line commands - equipment bv1250 technical reference page 30 revision 1.0 item 1-5: dns-time (set and get) class equipment command function commands used to set and get dns server time characteristics set-dns-time writes access start time and access cycle time to the bv1250. Start time is the tim...
Page 75
Bv1250 technical reference on-line commands - equipment revision 1.0 page 31 item 1-6: dns-ver (set and get) class equipment command function commands to set and get the dns version number characteristics set-dns-ver writes dns version number to bv1250 and returns new version input parameter(s): p1 ...
Page 76
On-line commands - equipment bv1250 technical reference page 32 revision 1.0 item 1-7: email -adr (set, get, and rst) class equipment command function commands to set, get, and reset e-mail address for notification of unit events and alarms characteristics set-email-adr input parameter(s): p1 - inpu...
Page 77
Bv1250 technical reference on-line commands - equipment revision 1.0 page 33 example(s) set-email-adr nnnnnnnnnnnnnnn nnnnnnnnnnnnnn #set-email-adr tokyo@oki.Co.Jp oosaka@oki.Co.Jp act email address1=”tokyo@okisiba.Co.Jp” sby email address1=”tokyo@oki.Co.Jp” act email address2=”oosaka@okisiba.Co.Jp”...
Page 78
On-line commands - equipment bv1250 technical reference page 34 revision 1.0 item 1-8: fan -flt (set and get) class equipment command function command to configure fan fault feature to cause unit to continue processing calls on fault or cease process calls on fault. Characteristics set-fan-flt input...
Page 79
Bv1250 technical reference on-line commands - equipment revision 1.0 page 35 item 1-9: gk-ip (set, get, and rst) class equipment command function commands used to set, reset, and get ip address of gatekeeper configured in a bv1250 unit. Characteristics set-gk-ip writes gatekeeper ip address(es) to a...
Page 80
On-line commands - equipment bv1250 technical reference page 36 revision 1.0 example(s) set-gk-ip nnn.Nnn.Nnn.Nnn #set-gk-ip 172.17.68.199 172.17.68.198 gatekeeper 1 act ip address=***.***.***.*** sby ip address=172.17.68.199 gatekeeper 2 act ip address=***.***.***.*** sby ip address=172.17.68.198 ....
Page 81
Bv1250 technical reference on-line commands - equipment revision 1.0 page 37 item 1-10: gw-ip (set, get, and rst) class equipment command function commands used to set, reset, and get gateway ip address of bv1250 characteristics set-gw-ip writes gateway ip address to a bv1250 unit and displays new a...
Page 82
On-line commands - equipment bv1250 technical reference page 38 revision 1.0 example(s) set-gw-ip nnn.Nnn.Nnn.Nnn #set-gw-ip 133.149.216.103 gateway 1 act ip address=133.149.216.101 sby ip address=133.149.216.103 ...Set-gw-ip command end. [thu may 28 17:00:23 1996] # rst-gw-ip #rst-gw-ip gateway 1 a...
Page 83
Bv1250 technical reference on-line commands - equipment revision 1.0 page 39 item 1-11: ip ( set and get) class equipment command function commands used to set and get ip address of bv1250 characteristics set-ip writes ip address to a bv1250 unit and displays new address input parameter(s): p1 - inp...
Page 84
On-line commands - equipment bv1250 technical reference page 40 revision 1.0 item 1-12: mac-adr(get) class equipment command function command to get the mac address of bv1250 characteristics get-mac-adr returns mac address of a bv1250 input parameter(s): none output parameter(s): displays current ma...
Page 85
Bv1250 technical reference on-line commands - equipment revision 1.0 page 41 item 1-13: rx -buffer (set and get) class equipment command function command to set the unit receive buffer size and recovery parameters characteristics set-rx-buffer input parameter(s): p1 - maximum receive buffer size ent...
Page 86
On-line commands - equipment bv1250 technical reference page 42 revision 1.0 item 1-14: smtp-adr (set, get, and rst) class equipment command function set, get, and reset smtp address(es) to be associated with unit. Characteristics set-smtp-adr input parameter(s): p1 - input for smtp-server ip addres...
Page 87
Bv1250 technical reference on-line commands - equipment revision 1.0 page 43 example(s) set-smtp-adr nnn.Nnn.Nnn.Nnn nnn.Nnn.Nnn.Nnn #set-smtp-adr 192.168.10.11 192.168.10.15 smtp address 1 act ip address=192.168.10.23 sby ip address=192.168.10.11 smtp address 2 act ip address=192.168.10.24 sby ip a...
Page 88
On-line commands - equipment bv1250 technical reference page 44 revision 1.0 item 1-15: snmp-trpdst (set, get, and rst) class equipment command function commands used to set, reset and get snmp trap destination of bv1250 characteristics set-snmp-trpdst writes from 1 to 3 snmp trap destination ip add...
Page 89
Bv1250 technical reference on-line commands - equipment revision 1.0 page 45 example(s) set-snmp-trpdst nnn.Nnn.Nnn.Nnn nnn.Nnn.Nnn.Nnn.Nnn.Nnn.Nnn.Nnn #set snmp trpdst 133.149.216.103 133.149.216.104 133.149.216.105 act snmp trap 1=133.149.216.203 sby snmp trap 1=133.149.216.103 act snmp trap 2=133...
Page 90
On-line commands - equipment bv1250 technical reference page 46 revision 1.0 item 1-16: tone (set and get) class equipment command function commands to set and get frequencies and interval values of audible tones for a bv1250 unit characteristics set-tone writes modification parameters (tone, freque...
Page 91
Bv1250 technical reference on-line commands - equipment revision 1.0 page 47 example(s) set-tone n n n # set-tone 1 8 1 act_tone_dt=1 sby_tone_dt=8 ... Set-tone command end. [thu feb 12 17:00:23 1999] # # set-tone 7 100 crot.Tone 7 act_tone_rot=7 5 sby_tone_rot=7 100 crot.Tone ... Set-tone command e...
Page 92
On-line commands - equipment bv1250 technical reference page 48 revision 1.0 table: tone type values value default pattern frequency (hz) type of modulation level (dbm) interval(ms) 0 none tone --- --- --- --- 1 jp-dt 400 single -16 250(on) 250(off) 2 jp-rbt 400/20 am -13 1000(on) 1000(off) 3 jp-bt,...
Page 93
Bv1250 technical reference on-line commands - equipment revision 1.0 page 49 table: initial tone values north american tone class frequency interval value (msec) level parameter 1 parameter 2 dt 350+440 continuous tone -13/-13 1 8 rbt 440+480 2000 (on) 4000 (off) -19/-19 2 9 bt 480+620 500 (on) 500 ...
Page 94
On-line commands - equipment bv1250 technical reference page 50 revision 1.0 item 1-17: trp-commu (set and get) class equipment command function command to set and get community name for trap transmission characteristics set-trp-commu writes a community name for trap transmission to a bv1250 unit an...
Page 95
Bv1250 technical reference on-line commands - equipment revision 1.0 page 51 item 1-18: vbm-domain(set , get, and rst) class equipment command function commands to set, get, and reset domain name in a bv1250 unit. Characteristics set-vbm-domain writes domain name to a bv1250 unit and displays new na...
Page 96
On-line commands - equipment bv1250 technical reference page 52 revision 1.0 example(s) set-vbm-domain #set-vbm-domain tokyo.Oki.Co.Jp act domain name=tokyo. Oki_siba.Co.Jp sby domain name=tokyo. Oki.Co.Jp ...Set-vbm-domain command end. [thu may 28 17:00:23 1996] # get-vbm-domain #get-vbm-domain act...
Page 97
Bv1250 technical reference on-line commands - equipment revision 1.0 page 53 item 1-19: vbm-subnet ( set and get) class equipment command function commands used set and get the subnet mask of bv1250 characteristics set-vbm-subnet writes subnet address to a bv1250 unit and displays new address input ...
Page 98
On-line commands – maint. Console bv1250 technical reference page 54 revision 1.0 5.2 maintenance console commands maintenance console commands are used to configure user access, manage on-line sessions, and obtain on-line help for commands. The following commands are described: 2-1: diff 2-2: help ...
Page 99
Bv1250 technical reference command reference – maint. Console commands revision 1.0 page 55 item 2-1: diff class maintenance console command function command to display active (act) and standby (sby) configuration parameters recorded in maintenance console software characteristics diff displays diff...
Page 100
On-line commands – maint. Console bv1250 technical reference page 56 revision 1.0 item 2-2: help or ? Class maintenance console command function command to display parameter description and/or help for specified command characteristics help or ? Displays parameter description summary for the specifi...
Page 101
Bv1250 technical reference command reference – maint. Console commands revision 1.0 page 57 item 2-3: logout class maintenance console command function commands to log out from maintenance console software characteristics logout ends session and terminates serial or telnet connection input parameter...
Page 102
On-line commands – maint. Console bv1250 technical reference page 58 revision 1.0 item 2-4: lst-mod ( set and get ) class maintenance console command function commands to set terminal output mode characteristics set-lst-mod sets terminal output mode to overrun or page by page mode input parameter(s)...
Page 103
Bv1250 technical reference command reference – maint. Console commands revision 1.0 page 59 item 2-5: pass-m (set) class maintenance console command function command to set maintenance level password characteristics set-pass-m changes the maintenance level password and writes new password to bv1250 ...
Page 104
On-line commands – maint. Console bv1250 technical reference page 60 revision 1.0 item 2-6: pass-u (set) class maintenance console command function command to set user level password characteristics set-pass-u changes the user level password and writes new password to bv1250 unit. Input parameter(s)...
Page 105
Bv1250 technical reference command reference – maint. Console commands revision 1.0 page 61.
Page 106
On-line commands - numbering plan bv1250 technical reference page 62 revision 1.0 5.3 numbering plan commands numbering plan commands are used to configure a bv1250 numbering plan. This information is configured in the unit’s data file (ofdd.Vho) and is also used in dns.Dat file configuration. All p...
Page 107
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 63 item 3-1: acposi (set and get) class numbering plan command function command to set and get dial location (position) of voice and fax access codes characteristics set-acposi writes code for location (position) at which...
Page 108
On-line commands - numbering plan bv1250 technical reference page 64 revision 1.0 item 3-2: daynight(set, get, and rst) class numbering plan command function commands used to set, get, and reset day and night forwarding numbers for fxo units with the dil feature enabled. Characteristics set-daynight...
Page 109
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 65 access set-daynight: rs-232c and lan get-daynight: rs-232c and lan rst-daynight: rs-232c and lan example(s) set-daynight n nnnn nnnn nnnn #set-daynight 1 2 0800-1700 pattern=2 act daytime=0000-2400 sby daytime=0800-170...
Page 110
On-line commands - numbering plan bv1250 technical reference page 66 revision 1.0 errors no. 0101: cause - type value out of range remedy - correct value and retry no. 0102: cause - pattern number value out of range remedy - correct value and retry no. 0103: cause - time parameter value out of range...
Page 111
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 67 item 3-3: did-id(set and get) class numbering plan command function commands used to set and get bv1250 fxo unit port disa enabled or disabled parameter. Characteristics set-did-id writes disa enabled/disabled paramete...
Page 112
On-line commands - numbering plan bv1250 technical reference page 68 revision 1.0 item 3-4: did-id-no(set, get, and rst) class numbering plan command function commands used to set, get, and reset bs120 fxo unit port disa password parameter. Characteristics set-did-id-no writes disa password paramete...
Page 113
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 69 example(s) set-did-id-no n n #set-did-id-no 3 4321 port=1 act did id number sby did id number "1234" "1234" port=2 act did id number sby did id number "1234" "1234" port=3 act did id number sby did id number "4321" por...
Page 114
On-line commands - numbering plan bv1250 technical reference page 70 revision 1.0 item 3-5: dil(set, get, and rst) class numbering plan command function commands used to set, get, and reset bs120 fxo unit port dil day and night forwarding numbers. Characteristics set-did-id-no writes dil day and nig...
Page 115
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 71 example(s) set-dil n n #set-dil 1 4085551212 4082225555 act port=1 day no=******************************** night no=******************************** sby port=1 day no="4085551212" night no="4082225555" ...Set-dil comma...
Page 116
On-line commands - numbering plan bv1250 technical reference page 72 revision 1.0 item 3-6: faxsp (set, get, and rst) class numbering plan command function commands used to set, get, and reset fax access code characteristics set-voicesp writes fax access code to bv1250 unit input parameter(s): p1 - ...
Page 117
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 73 example(s) set- faxsp nnnnnnnn #set-faxsp 9 act fax access code="5" sby fax access code="9" ...Set-faxsp command end. [thu jan 30 18:19:23 1997] # get- faxsp #get-faxsp act fax access code="5" sby fax access code="9" ....
Page 118
On-line commands - numbering plan bv1250 technical reference page 74 revision 1.0 item 3-7: hnt (set, get, and rst) class numbering plan command function command to set, get and reset terminal hunt group (bv1250 fxs equipped units only) characteristics set-hnt writes parameters for a terminal hunt g...
Page 119
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 75 access set-hnt: rs-232c and lan get-hnt: rs-232c and lan rst-hnt : rs-232c and lan example(s) set-hnt n n n n #set-hnt 1 1 4 2 act group=1 port sequence=* sby group=1 port sequence=1,4,2 ...Set-hnt command end. [tue ma...
Page 120
On-line commands - numbering plan bv1250 technical reference page 76 revision 1.0 item 3-8: hntptn (set, get, and rst) class numbering plan command function commands used to set, reset, and get hunt-pattern number and destination number for bv1250 e&m and bv1250 fxo units. Characteristics set- hntpt...
Page 121
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 77 example(s) set-hntptn nnn n nnn… #set-hntptn 2 3 4085551212 30 act index=2 hunt ptn.=* destination number=******************************** response time=* sby index=2 hunt ptn.=3 destination number="4085551212" respons...
Page 122
On-line commands - numbering plan bv1250 technical reference page 78 revision 1.0 item 3-9: pre (set, get, and rst) class numbering plan command function command to set, get, and reset the intra-office number (office code) characteristics set-pre writes intra-office number (office code) to bv1250 un...
Page 123
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 79 example(s) set-pre nnnnnnnn #set-pre 24 act_prefix_num="21" sby_prefix_num="24" ...Set-pre command end. [fri jan 31 10:48:23 1997] # get-pre #get-pre act_prefix_num="21" sby_prefix_num="24" ...Set-pre command end. [fri...
Page 124
On-line commands - numbering plan bv1250 technical reference page 80 revision 1.0 item 3-10: res-no (set, get, and rst) class numbering plan command function commands used to set, get, and reset bv1250 fxo unit restricted dialing prefix numbers. Characteristics set-res-no writes restricted number(s)...
Page 125
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 81 example(s) set-res-no nnnn #set-res-no 1234 act restriction number sby restriction number "1234" ...Set-res-no command end. [tue may 25 14:56:07 1999 gw] # get-res-no #get-res-no act restriction number sby restriction ...
Page 126
On-line commands - numbering plan bv1250 technical reference page 82 revision 1.0 item 3-11: spd (set, get , and rst) class numbering plan command function commands used to set, get, and reset bv1250 fxo unit speed dial codes and calling numbers. Characteristics set-spd writes speed dial code and ca...
Page 127
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 83 example(s) set-spd nn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn #set-spd 01 4085551212 act spd dial no=01 dialed no=******************************** sby spd dial no=01 dialed no="4085551212" ...Set-spd command end. [tue may 25 ...
Page 128
On-line commands - numbering plan bv1250 technical reference page 84 revision 1.0 item 3-12: tgn (set and get) class numbering plan command function commands to set and get the trunk group number and the number of digits deleted from a destination number characteristics set-tgn writes trunk group nu...
Page 129
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 85 example(s) set-tgn n nn #set-tgn 1 3 act trunk group=1 delete digits=4 sby trunk group=1 delete digits=3 ...Set-tgn command end. [fri jan 31 10:48:23 1997] # get-tgn #get-tgn act trunk group=1 delete digits=4 sby trunk...
Page 130
On-line commands - numbering plan bv1250 technical reference page 86 revision 1.0 item 3-13: trkrou (set, get, and rst) class numbering plan command function commands used to set, get, and reset trunk-hunt routing priority order characteristics set-trkrou writes trunk hunt-pattern number, priority n...
Page 131
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 87 example(s) set-trkrou n n n #set-trkrou 1 1 2 hntptn_num=1 priority=1 act trunk group number=3 sby trunk group number=2 priority=2 act trunk group number=4 sby trunk group number=4 priority=3 act trunk group number=* s...
Page 132
On-line commands - numbering plan bv1250 technical reference page 88 revision 1.0 item 3-14: voicesp (set, get and rst) class numbering plan command function commands used to set, get, and reset voice access code characteristics set-voicesp writes voice access code to bv1250 unit input parameter(s):...
Page 133
Bv1250 technical reference on-line commands - numbering plan revision 1.0 page 89 example(s) set- voicesp nnnnnnnn #set-voicesp 4 act voice access code="5" sby voice access code="4" ...Set-voicesp command end. [thu jan 30 17:54:23 1997] # get- voicesp #get-voicesp act voice access code="5" sby voice...
Page 134
On-line commands – line information bv1250 technical reference page 90 revision 1.0 5.4 line information commands line information commands are used to configure a bv1250 unit’s ports, lines, and terminal interfaces. This information is configured in the unit’s data file (ofdd.Vho) and is also used ...
Page 135
Bv1250 technical reference on-line commands – line information revision 1.0 page 91 item 4-1: agc (set and get) class line information command function command to configure bv1250 port automatic gain control characteristics set-agc input parameter(s): p1 - port number entered as a number from 1 to 4...
Page 136
On-line commands – line information bv1250 technical reference page 92 revision 1.0 errors no. 0101: cause - port number out of range remedy - correct value and try again no. 0102: cause - used agc function value out of range remedy - correct value and try again no. 0103: cause - agc value out of ra...
Page 137
Bv1250 technical reference on-line commands – line information revision 1.0 page 93 item 4-2: ap-sysdld (set, get, and rst) class line information command function command to configure bv1250 ap (fxs) unit ringer configuration parameters characteristics set-ap-sysdld input parameter(s): p1 - ringer ...
Page 138
On-line commands – line information bv1250 technical reference page 94 revision 1.0 example(s) set-ap-sysdld n n nn n #set-ap-sysdld 1 1 10 0 act_ring_freq=0 sby_ring_freq=1 act_ring_inter=0 sby_ring_inte=1 act_pulse_signal=0 sby_pulse_signal=10 sby_signal_id=0 ...Set-ap-sysdld command end. [thu jan...
Page 139
Bv1250 technical reference on-line commands – line information revision 1.0 page 95 item 4-3: co-trmdld (set, get, and rst) class line information command function command to set, get, and reset circuit download parameters for a bv1250 fxo unit. Characteristics set-co-trmdld writes co circuit downlo...
Page 140
On-line commands – line information bv1250 technical reference page 96 revision 1.0 example(s) set-co-trmdld n n n n n n #set-co-trmdld 1 0 2 155 10 14 port=1 act dial speed=6 sby dial speed=0 act make rate=0 sby make rate=2 act reverse timing=125 sby reverce timing=155 act prepause timing=7 sby pre...
Page 141
Bv1250 technical reference on-line commands – line information revision 1.0 page 97 errors no. 0101: cause - port number out of range remedy - change value and retry no. 0102: cause - dp/dtmf value out of range remedy - correct value and retry no. 0103: cause - dp rate value out of range remedy - co...
Page 142
On-line commands – line information bv1250 technical reference page 98 revision 1.0 item 4-4: disc(set and get) class line information command function command to set and get disconnection timing value for a bv1250 e&m unit or bv1250 fxo unit. Characteristics set-disc writes disconnect value to bv12...
Page 143
Bv1250 technical reference on-line commands – line information revision 1.0 page 99 item 4-5: dld (set, get, and rst) class line information command function commands to set, get, and reset the download value of individual trunk line characteristics set-dld writes trunk-line configuration parameters...
Page 144
On-line commands – line information bv1250 technical reference page 100 revision 1.0 note startup method the two startup methods (delay-dial method and wink start method) for the e&m trunk line are used under the following conditions: 12. Use of the pre-pause (delay) method parameter p2 is determine...
Page 145
Bv1250 technical reference on-line commands – line information revision 1.0 page 101 output parameter(s): displays current (act) parameter for trunk line port specified in p1 get-dld displays trunk line parameters for all or a specified port on the bv1250 unit input parameter(s): p1 - port number en...
Page 146
On-line commands – line information bv1250 technical reference page 102 revision 1.0 errors no. 0101: cause - port number out of range remedy - change value and retry no. 0102: cause - delay-dial value out of range remedy - correct value and retry no. 0103: cause - wink start pulse width out of rang...
Page 147
Bv1250 technical reference on-line commands – line information revision 1.0 page 103 item 4-6: dtmf(set and get) class line information command function command to set and get dtmf enable/disable for functions; send, receive, and both directions for ports on a bv1250 unit equipped with the dtmf feat...
Page 148
On-line commands – line information bv1250 technical reference page 104 revision 1.0 example(s) set-dtmf n n #set-dtmf 3 3 act port=3 dtmf function=1 sby port=3 dtmf function=3 ...Set-dtmf command end. [tue may 25 15:29:26 1999 gw] # get-dtmf #get-dtmf act port=1 dtmf function=1 sby port=1 dtmf func...
Page 149
Bv1250 technical reference on-line commands – line information revision 1.0 page 105 item 4-7: law-flg (set and get) class line information command function command to set pcm bv1250 pcm signaling method characteristics set-law-flg input parameter(s): p1 – pcm signal method (0:a-law, 1:µ-law) output...
Page 150
On-line commands – line information bv1250 technical reference page 106 revision 1.0 item 4-8: pad-value (set and get) class line information command function commands to set and get incoming and outgoing pad level values. Characteristics set-pad-value writes pad level parameter to a bv1250 unit. (p...
Page 151
Bv1250 technical reference on-line commands – line information revision 1.0 page 107 example(s) set-pad-value n nn n #set-pad-value 3 10 –6 act port=3 up pad value=0db down pad value=0db sby port=3 up pad value=10db down pad value=-6db ...Set-pad-value command end. [tue may 25 15:32:50 1999 gw] # ge...
Page 152
On-line commands – line information bv1250 technical reference page 108 revision 1.0 item 4-9: term (set, get, and rst) class line information command function commands to set, get, and reset a bv1250 unit’s line information characteristics set-term writes line information parameters a port used in ...
Page 153
Bv1250 technical reference on-line commands – line information revision 1.0 page 109 example(s) set-term n n n #set- term 1 1 2 hntptn_num=1 priority=1 act_trunk_num=3 sby_trunk_num=2 priority=2 act_trunk_num=4 sby_trunk_num=4 priority=3 act_trunk_num=* sby_trunk_num=* priority=4 act_trunk_num=* sby...
Page 154
On-line commands – line information bv1250 technical reference page 110 revision 1.0 item 4-10: trk (set, get, and rst) class line information command function commands used to set, get and reset parameters for a specified trunk line characteristics set-trk writes trunk line parameters to a e&m/e&m ...
Page 155
Bv1250 technical reference on-line commands – line information revision 1.0 page 111 example(s) set-trk n n #set-trk 1 2 port_num=1 act_trunk_group_num=4 sby_trunk_group_num=2 ...Set-trk command end. [fri jan 31 14:29:23 1997] # get-trk #get-trk port_num=1 act_trunk_group_num=2 sby_trunk_group_num=4...
Page 156
On-line commands – management bv1250 technical reference page 112 revision 1.0 5.5 management commands management are used to obtain information about a bv1250 unit. The following commands are described: 5-1: usa 5-2: ver.
Page 157
Bv1250 technical reference on-line commands – management revision 1.0 page 113 item 5-1: usa class management command function command to display fault status of a bv1250 unit characteristics usa displays fault information for a bv1250 unit. Input parameter(s): p1 - when omitted, returns unit fault ...
Page 158
On-line commands – management bv1250 technical reference page 114 revision 1.0 item 5-2: ver class management command function command to get (display) version information for bv1250 unit and installed firmware characteristics ver retrieves version information for bv1250 unit and for firmware instal...
Page 159
Bv1250 technical reference on-line commands – management revision 1.0 page 115 access ver: rs-232c and lan example(s) ver n #ver bv12500 system vx. Xx-ap ...Ver command end. [thu may 28 17:00:23 1996] # ver 1 bv1250 system vx.Xx-ap ipl vx.Xx os vx.Xx opl vx.Xx cor vx.Xx net vx.Xx mas vx.Xx ccl vx.Xx...
Page 160
On-line commands – reports bv1250 technical reference page 116 revision 1.0 5.6 report commands report commands are used to retrieve and manage a bv1250 unit’s internal log files. The following commands are described: 6-1: elog 6-2: elog-clr 6-3: hist 6-4: hist-clr 6-5: trf.
Page 161
Oki bv1250 technical reference on-line commands – reports revision 1.0 page 117 item 6-1: elog class report command function command to get a fault log characteristics elog displays fault log for bv1250 unit input parameter(s): none output parameter(s): displays fault log records for specified unit....
Page 162
On-line commands – reports bv1250 technical reference page 118 revision 1.0 item 6-2: elog-clr class report command function command to clear fault log characteristics elog-clr clears the fault log on the bv1250 unit input parameter(s): none output parameter(s): displays confirmation of execution as...
Page 163
Oki bv1250 technical reference on-line commands – reports revision 1.0 page 119 item 6-3: hist class report command function command to get call detail record characteristics hist displays call detail record report for bs12200 unit for specified day input parameter(s): p1 - day of the week input as ...
Page 164
On-line commands – reports bv1250 technical reference page 120 revision 1.0 table: disconnection from remote terminal value meaning detail corrective action 0 normal disconnection -- -- 1 insufficient requested bandwidth network congestion try call later 2 insufficient gatekeeper resources -- try ca...
Page 165
Oki bv1250 technical reference on-line commands – reports revision 1.0 page 121 table: disconnection from originating terminal (q.931) value meaning detail corrective action 11020 service inactive terminal interfaces don’t match -- 11021 insufficient mandatory information terminal interfaces don’t m...
Page 166
On-line commands – reports bv1250 technical reference page 122 revision 1.0 table: disconnection from originating terminal (h.245) value meaning detail corrective action 11222 h.245 tcp connection closed -- try call later table: disconnection from originating terminal (h.323) value meaning detail co...
Page 167
Oki bv1250 technical reference on-line commands – reports revision 1.0 page 123 14007 received arj (bandwidth ng) recall after a while 14008 received arj (no registered self terminal) recall after a while 14009 received arj (other) not supported (it can not connected that terminal.) 14010 insufficie...
Page 168
On-line commands – reports bv1250 technical reference page 124 revision 1.0 item 6-4: hist-clr class report command function command to clear call history characteristics hist-clr clears call history on bv1250 unit for specified day input parameter(s): p1 - day of the week input as a number from 0 t...
Page 169
Oki bv1250 technical reference on-line commands – reports revision 1.0 page 125 item 6-5: trf class report command function command to get traffic report characteristics trf displays traffic report for specified day of week. Input parameter(s): p1 - day of the week input as a number from 0 to 6 wher...
Page 170
On-line commands – reports bv1250 technical reference page 126 revision 1.0 note the terminal display mode can be set by the set-lst-mod command to select between continuous and paged displays. See the set-lst-mod command. . Access trf: rs-232c and lan example(s) trf n n #trf 3 1 ### 1997/05/17 wed ...
Page 171
Bv1250 technical reference on-line commands – maintenance rev. 1.0 page 127 5.7 maintenance commands maintenance commands are used to operate a bv1250 unit’s file storage system and to shutdown and reboot the unit. The following commands are described: 7-1: dty 7-2: generate-sysd 7-3: oup 7-4: reboo...
Page 172
On-line commands – maintenance bv1250 technical reference page 128 rev. 1.0 item 7-1: dty class maintenance command function command to set the system date and time characteristics dty sets the system time and date on the bv1250 unit input parameter(s): p1 – year entered as a four digit number, i.E....
Page 173
Bv1250 technical reference on-line commands – maintenance rev. 1.0 page 129 item 7-2: generate-sysd class maintenance command function command to generate a new default system file for a bv1250 unit. Characteristics gernerate-sysd writes a new defaulted system file to the bv1250 unit input parameter...
Page 174
On-line commands – maintenance bv1250 technical reference page 130 rev. 1.0 item 7-3: oup class maintenance command function command to write (backup) configuration data to the bv1250 unit office data file characteristics oup office data backup command causes the contents of commands entered to the ...
Page 175
Bv1250 technical reference on-line commands – maintenance rev. 1.0 page 131 item 7-4: reboot class maintenance command function this command reboots the bv1250 characteristics reboots the bs1200 input parameter(s): p1 - when omitted, reboot after all call terminate. When specified as 1, force reboot...
Page 176
On-line commands – maintenance bv1250 technical reference page 132 rev. 1.0 item 7-5: shutdown class maintenance command function this command shuts down the bv1250 characteristics shutdown shuts down the bv1250 unit input parameter(s): none output parameter(s): displays a confirmation request “sure...
Page 177
Bv1250 technical reference on-line commands – maintenance rev. 1.0 page 133 item 7-6: volinit class maintenance command function command to initialize volume of flash memory characteristics volinit initialize a specified volume of a bv1250 unit’s flash memory by deleting files associated with specif...
Page 178
On-line commands – maintenance bv1250 technical reference page 134 rev. 1.0 volume 3.7 (traffic and call log for friday) • traffic information (traff.Log) • call log (call.Log) volume 3.8 (traffic and call log for saturday) • traffic information (traff.Log) • call log (call.Log) volume 3.9 (fault lo...
Page 179
Bv1250 technical reference on-line commands – maintenance rev. 1.0 page 135 remedy - try again. If error occurs frequently, replace unit no. 0104: cause - directory creation failed remedy - try again. If error occurs frequently, replace unit no. 0105: cause - initialization failed because the file i...
Page 180
On-line commands – maintenance bv1250 technical reference page 136 rev. 1.0
Page 181
Bv1250 technical reference on-line commands – lan interface rev. 1.0 page 137 5.8 lan interface commands fxo interface commands are used to configure a bv1250 fxo unit’s interface with a pstn and/or pbx in the unit’s data file (ofdd.Vho) all parameters entered are displayed as sby until they are bac...
Page 182
On-line commands – lan interface bv1250 technical reference page 138 rev. 1.0 item 8-1: call-port (set and get) class lan interface command function commands to set and get unit call signaling port number characteristics set-call-port writes the call signaling port number to a bv1250 unit and displa...
Page 183
Bv1250 technical reference on-line commands – lan interface rev. 1.0 page 139 item 8-2: firewall-check class lan interface command function command to check (ping) for correct firewall port assignments. Characteristics firewall-check returns firewall port access for tcp and udp transmission from bv1...
Page 184
On-line commands – lan interface bv1250 technical reference page 140 rev. 1.0 item 8-3: h245-port (set and get) class lan interface command function commands to set and get unit h.245 start tcp port number characteristics set-h245-port writes the h.245 start tcp port number to a bv1250 unit and disp...
Page 185
Bv1250 technical reference on-line commands – lan interface rev. 1.0 page 141 item 8-4: noctime ( set and get) class lan interface command function commands used to set and get tcp setup timeout parameter for a bv1250 characteristics set-noctime writes call setup time-out value in seconds to a bv125...
Page 186
On-line commands – lan interface bv1250 technical reference page 142 rev. 1.0 item 8-5: rtcpinfo class lan interface command function command to get rtcp information for bv1250 unit. This information relates to gateway to gateway communications and control. Characteristics rtcpinfo returns bv1250 rt...
Page 187
Bv1250 technical reference on-line commands – lan interface rev. 1.0 page 143 item 8-6: rtp-head(set and get) class lan interface command function command to set and get rtp header type for bv1250 unit. This parameter determines the if the voice transmission protocol used by the bv1250 unit will be ...
Page 188
On-line commands – lan interface bv1250 technical reference page 144 rev. 1.0 item 8-7: rtp-port (set and get) class lan interface command function commands to set and get unit rtp start port number characteristics set-rtp-port writes the rtp start port number to a bv1250 unit and displays current a...
Page 189
Bv1250 technical reference on-line commands – lan interface rev. 1.0 page 145 item 8-8: test-port (get) class lan interface command function diagnostic command to check for correct port assignments. Characteristics get-test-port returns port assignment information from bv1250 unit input parameter(s)...
Page 190
On-line commands – lan interface bv1250 technical reference page 146 rev. 1.0 item 8-9: uplink (set and get) class lan interface command function command to set and get uplink parameters for bs1200 unit. Parameters configure network timing used when monitoring link between a gateway and a router, hu...
Page 191
Bv1250 technical reference on-line commands – lan interface rev. 1.0 page 147 errors no. 0101: cause - regular time period value out of range remedy - correct value and retry no. 0102: cause - error detect time period value out of range remedy - correct value and retry no. 0103: cause - disconnect a...
Page 192
On-line commands – lan interface bv1250 technical reference page 148 rev. 1.0 item 8-10: voicecond (set and get) class lan interface command function command to set and get voice condition parameters for bv1250 unit. Parameter sets payload size to bandwidth ratio to optimize voice transmission. . Ch...
Page 193
Bv1250 technical reference on-line commands – fxo interface rev. 1.0 page 149 5.9 fxo interface commands fxo interface commands are used to configure a bv1250 fxo unit’s interface with a pstn and/or pbx in the unit’s data file (ofdd.Vho) all parameters entered are displayed as sby until they are bac...
Page 194
On-line commands – fxo interface bv1250 technical reference page 150 rev. 1.0 item 9-1: co-atdrp (set, get, and rst) class fxo interface command function command to set bv1250 fxo unit co auto drop time (the time that will elapse between the interruption of the pstn ringing tone and the assertion of...
Page 195
Bv1250 technical reference on-line commands – fxo interface rev. 1.0 page 151 example(s) set-co-atdrp nn #set-co-atdrp 5 act auto dropout time=5 sby auto dropout time=5 ...Set-co-atdrp command end. [tue may 25 09:54:44 1999 gw] # get-co-atdrp #get-co-atdrp act auto dropout time=5 sby auto dropout ti...
Page 196
On-line commands – fxo interface bv1250 technical reference page 152 rev. 1.0 item 9-2: did-tim(set and get) class fxo interface command function command to set and get disa response timing for a bv1250 fxo unit. When call is placed from the pstn to an fxo unit, the pstn sends a ringing tone to the ...
Page 197
Bv1250 technical reference on-line commands – fxo interface rev. 1.0 page 153 item 9-3: tone-det (set and get) class fxo interface command function command to configure fxo unit interface parameters characteristics set-tone-det input parameter(s): p1 - type of tone detect, 1 to 3 (1:originating dial...
Page 198
On-line commands – fxo interface bv1250 technical reference page 154 rev. 1.0